CVE-2020-7360 (GCVE-0-2020-7360)
Vulnerability from cvelistv5 – Published: 2020-08-13 19:05 – Updated: 2024-09-17 01:21
VLAI
Title
Philips SmartControl DLL Hijacking
Summary
An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April 15, 2020. (Note, the version numbering system changed significantly between version 4.3.15 and version 1.0.7.)
Severity
7.4 (High)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://blog.vonahi.io/when-the-path-to-system-is… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | SmartControl |
Affected:
4.3.15
Unaffected: 1.0.7 |
Date Public
2020-08-06 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:25:48.983Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://blog.vonahi.io/when-the-path-to-system-is-wide-open/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SmartControl",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "4.3.15"
},
{
"status": "unaffected",
"version": "1.0.7"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was discovered and reported by Erik Wynter of Vonahi Security."
}
],
"datePublic": "2020-08-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April 15, 2020. (Note, the version numbering system changed significantly between version 4.3.15 and version 1.0.7.)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-08-13T19:05:15.000Z",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://blog.vonahi.io/when-the-path-to-system-is-wide-open/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Philips SmartControl DLL Hijacking",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@rapid7.com",
"DATE_PUBLIC": "2020-08-06T13:27:00.000Z",
"ID": "CVE-2020-7360",
"STATE": "PUBLIC",
"TITLE": "Philips SmartControl DLL Hijacking"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SmartControl",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "4.3.15",
"version_value": "4.3.15"
},
{
"version_affected": "!",
"version_name": "1.0.7",
"version_value": "1.0.7"
}
]
}
}
]
},
"vendor_name": "Philips"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This issue was discovered and reported by Erik Wynter of Vonahi Security."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April 15, 2020. (Note, the version numbering system changed significantly between version 4.3.15 and version 1.0.7.)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://blog.vonahi.io/when-the-path-to-system-is-wide-open/",
"refsource": "MISC",
"url": "https://blog.vonahi.io/when-the-path-to-system-is-wide-open/"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2020-7360",
"datePublished": "2020-08-13T19:05:15.783Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:21:03.461Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-7360",
"date": "2026-06-04",
"epss": "0.00069",
"percentile": "0.2136"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:philips:smartcontrol:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"4.3.15\", \"matchCriteriaId\": \"AA868B5E-9DFE-4741-9EDF-C06FB73FBAAA\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April 15, 2020. (Note, the version numbering system changed significantly between version 4.3.15 and version 1.0.7.)\"}, {\"lang\": \"es\", \"value\": \"(CWE-427) Una vulnerabilidad de Elemento Ruta B\\u00fasqueda no Controlada en SmartControl versi\\u00f3n 4.3.15 y versiones publicadas antes del 15 de abril de 2020, puede permitir a un usuario autenticado escalar privilegios al colocar un archivo DLL especialmente dise\\u00f1ado en la ruta de b\\u00fasqueda. Este problema fue corregido en la versi\\u00f3n 1.0.7, que fue publicado despu\\u00e9s del 15 de abril de 2020 (tome en cuenta que el sistema de numeraci\\u00f3n de versiones cambi\\u00f3 significativamente entre la versi\\u00f3n 4.3.15 y la versi\\u00f3n 1.0.7)\"}]",
"id": "CVE-2020-7360",
"lastModified": "2024-11-21T05:37:06.860",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cve@rapid7.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:L\", \"baseScore\": 7.4, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 0.8, \"impactScore\": 6.0}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.3, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:M/Au:N/C:C/I:C/A:C\", \"baseScore\": 6.9, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.4, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2020-08-13T19:15:14.113",
"references": "[{\"url\": \"https://blog.vonahi.io/when-the-path-to-system-is-wide-open/\", \"source\": \"cve@rapid7.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://blog.vonahi.io/when-the-path-to-system-is-wide-open/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
"sourceIdentifier": "cve@rapid7.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cve@rapid7.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-427\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-427\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7360\",\"sourceIdentifier\":\"cve@rapid7.com\",\"published\":\"2020-08-13T19:15:14.113\",\"lastModified\":\"2024-11-21T05:37:06.860\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April 15, 2020. (Note, the version numbering system changed significantly between version 4.3.15 and version 1.0.7.)\"},{\"lang\":\"es\",\"value\":\"(CWE-427) Una vulnerabilidad de Elemento Ruta B\u00fasqueda no Controlada en SmartControl versi\u00f3n 4.3.15 y versiones publicadas antes del 15 de abril de 2020, puede permitir a un usuario autenticado escalar privilegios al colocar un archivo DLL especialmente dise\u00f1ado en la ruta de b\u00fasqueda. Este problema fue corregido en la versi\u00f3n 1.0.7, que fue publicado despu\u00e9s del 15 de abril de 2020 (tome en cuenta que el sistema de numeraci\u00f3n de versiones cambi\u00f3 significativamente entre la versi\u00f3n 4.3.15 y la versi\u00f3n 1.0.7)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@rapid7.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:L\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":0.8,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.3,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":6.9,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.4,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cve@rapid7.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-427\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-427\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:philips:smartcontrol:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.3.15\",\"matchCriteriaId\":\"AA868B5E-9DFE-4741-9EDF-C06FB73FBAAA\"}]}]}],\"references\":[{\"url\":\"https://blog.vonahi.io/when-the-path-to-system-is-wide-open/\",\"source\":\"cve@rapid7.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://blog.vonahi.io/when-the-path-to-system-is-wide-open/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…