cve-2021-1267
Vulnerability from cvelistv5
Published
2021-01-13 21:45
Modified
2024-09-16 18:08
Severity
Summary
Cisco Firepower Management Center XML Entity Expansion Vulnerability
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T16:02:56.339Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20210113 Cisco Firepower Management Center XML Entity Expansion Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-xee-DFzARDcs"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Firepower Management Center",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2021-01-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the dashboard widget of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to improper restrictions on XML entities. An attacker could exploit this vulnerability by crafting an XML-based widget on an affected server. A successful exploit could cause increased memory and CPU utilization, which could result in a DoS condition."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-776",
              "description": "CWE-776",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-13T21:45:49",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20210113 Cisco Firepower Management Center XML Entity Expansion Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-xee-DFzARDcs"
        }
      ],
      "source": {
        "advisory": "cisco-sa-fmc-xee-DFzARDcs",
        "defect": [
          [
            "CSCvt63027"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Firepower Management Center XML Entity Expansion Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2021-01-13T16:00:00",
          "ID": "CVE-2021-1267",
          "STATE": "PUBLIC",
          "TITLE": "Cisco Firepower Management Center XML Entity Expansion Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Firepower Management Center",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the dashboard widget of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to improper restrictions on XML entities. An attacker could exploit this vulnerability by crafting an XML-based widget on an affected server. A successful exploit could cause increased memory and CPU utilization, which could result in a DoS condition."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "4.3",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-776"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20210113 Cisco Firepower Management Center XML Entity Expansion Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-xee-DFzARDcs"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-fmc-xee-DFzARDcs",
          "defect": [
            [
              "CSCvt63027"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2021-1267",
    "datePublished": "2021-01-13T21:45:49.441874Z",
    "dateReserved": "2020-11-13T00:00:00",
    "dateUpdated": "2024-09-16T18:08:47.755Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-1267\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2021-01-13T22:15:21.380\",\"lastModified\":\"2021-01-20T16:29:47.890\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the dashboard widget of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to improper restrictions on XML entities. An attacker could exploit this vulnerability by crafting an XML-based widget on an affected server. A successful exploit could cause increased memory and CPU utilization, which could result in a DoS condition.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en el widget dashboard del software Cisco Firepower Management Center (FMC), podr\u00eda permitir a un atacante remoto autenticado causar una condici\u00f3n de denegaci\u00f3n de servicio (DoS) en un dispositivo afectado.\u0026#xa0;La vulnerabilidad es debido a restricciones inapropiadas en entidades XML.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad al crear un widget basado en XML en un servidor afectado.\u0026#xa0;Una explotaci\u00f3n con \u00e9xito podr\u00eda causar una mayor utilizaci\u00f3n de la memoria y la CPU, lo que podr\u00eda resultar en una condici\u00f3n DoS.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:N/I:N/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":4.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-776\"}]},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-776\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.6.1\",\"matchCriteriaId\":\"30A98AEB-A175-4B14-BD2A-98FF305D321E\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-xee-DFzARDcs\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...