cve-2021-1463
Vulnerability from cvelistv5
Published
2021-04-08 04:06
Modified
2024-09-17 00:06
Severity
Summary
Cisco Unified Intelligence Center Reflected Cross-Site Scripting Vulnerability
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T16:11:17.322Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20210407 Cisco Unified Intelligence Center Reflected Cross-Site Scripting Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-cuic-xss-U2WTsUg6"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Unified Contact Center Express",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2021-04-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web-based management interface of Cisco Unified Intelligence Center Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. This vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by persuading a user of an affected interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-08T04:06:46",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20210407 Cisco Unified Intelligence Center Reflected Cross-Site Scripting Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-cuic-xss-U2WTsUg6"
        }
      ],
      "source": {
        "advisory": "cisco-sa-cuic-xss-U2WTsUg6",
        "defect": [
          [
            "CSCvx10201",
            "CSCvx10205"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Unified Intelligence Center Reflected Cross-Site Scripting Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2021-04-07T16:00:00",
          "ID": "CVE-2021-1463",
          "STATE": "PUBLIC",
          "TITLE": "Cisco Unified Intelligence Center Reflected Cross-Site Scripting Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Unified Contact Center Express",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the web-based management interface of Cisco Unified Intelligence Center Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. This vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by persuading a user of an affected interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "6.1",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20210407 Cisco Unified Intelligence Center Reflected Cross-Site Scripting Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-cuic-xss-U2WTsUg6"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-cuic-xss-U2WTsUg6",
          "defect": [
            [
              "CSCvx10201",
              "CSCvx10205"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2021-1463",
    "datePublished": "2021-04-08T04:06:46.177478Z",
    "dateReserved": "2020-11-13T00:00:00",
    "dateUpdated": "2024-09-17T00:06:05.859Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-1463\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2021-04-08T04:15:13.530\",\"lastModified\":\"2023-11-07T03:28:22.227\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based management interface of Cisco Unified Intelligence Center Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. This vulnerability exists because the web-based management interface does not properly validate user-supplied input. An attacker could exploit this vulnerability by persuading a user of an affected interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz de administraci\u00f3n basada en web del software Cisco Unified Intelligence Center, podr\u00eda permitir a un atacante remoto no autenticado conducir un ataque de tipo cross-site scripting (XSS) contra un usuario de la interfaz.\u0026#xa0;Esta vulnerabilidad se presenta porque la interfaz de administraci\u00f3n basada en web no comprueba apropiadamente la entrada suministrada por el usuario.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad al persuadir a un usuario de una interfaz afectada para que haga clic en un enlace dise\u00f1ado.\u0026#xa0;Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante ejecutar c\u00f3digo de script arbitrario en el contexto de la interfaz afectada o acceder a informaci\u00f3n confidencial basada en el navegador\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:unified_contact_center_express:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"12.0\\\\(1\\\\)\",\"matchCriteriaId\":\"2E8430E2-42B7-4BF3-A9C6-DF30FCD64854\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:unified_contact_center_express:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.5\\\\(1\\\\)\",\"versionEndExcluding\":\"12.5\\\\(1\\\\)su1\",\"matchCriteriaId\":\"2A812DE0-FA3C-4361-8CC2-269E43AA976A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:unified_intelligence_center:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"11.6\\\\(1\\\\)\",\"matchCriteriaId\":\"3643E7AD-2347-4ADC-B80C-B0E0D225A645\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:unified_intelligence_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0\\\\(1\\\\)\",\"versionEndExcluding\":\"12.0\\\\(1\\\\)es14\",\"matchCriteriaId\":\"DB961D31-384B-419A-B5E1-22F290860ADE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:unified_intelligence_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.5\\\\(1\\\\)\",\"versionEndExcluding\":\"12.5\\\\(1\\\\)es7\",\"matchCriteriaId\":\"472FF7A5-997E-432B-A08B-C5AB0F29D306\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-cuic-xss-U2WTsUg6\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.