cve-2021-20150
Vulnerability from cvelistv5
Published
2021-12-30 21:31
Modified
2024-08-03 17:30
Severity ?
Summary
Trendnet AC2600 TEW-827DRU version 2.08B01 improperly discloses information via redirection from the setup wizard. Authentication can be bypassed and a user may view information as Admin by manually browsing to the setup wizard and forcing it to redirect to the desired page.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:30:07.420Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2021-54"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Trendnet AC2600 TEW-827DRU",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "2.08B01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Trendnet AC2600 TEW-827DRU version 2.08B01 improperly discloses information via redirection from the setup wizard. Authentication can be bypassed and a user may view information as Admin by manually browsing to the setup wizard and forcing it to redirect to the desired page."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-30T21:31:12",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2021-54"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2021-20150",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Trendnet AC2600 TEW-827DRU",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2.08B01"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Trendnet AC2600 TEW-827DRU version 2.08B01 improperly discloses information via redirection from the setup wizard. Authentication can be bypassed and a user may view information as Admin by manually browsing to the setup wizard and forcing it to redirect to the desired page."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information disclosure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2021-54",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2021-54"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2021-20150",
    "datePublished": "2021-12-30T21:31:12",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:30:07.420Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-20150\",\"sourceIdentifier\":\"vulnreport@tenable.com\",\"published\":\"2021-12-30T22:15:08.623\",\"lastModified\":\"2022-07-12T17:42:04.277\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Trendnet AC2600 TEW-827DRU version 2.08B01 improperly discloses information via redirection from the setup wizard. Authentication can be bypassed and a user may view information as Admin by manually browsing to the setup wizard and forcing it to redirect to the desired page.\"},{\"lang\":\"es\",\"value\":\"Trendnet AC2600 TEW-827DRU versi\u00f3n 2.08B01, revela inapropiadamente informaci\u00f3n por medio de la redirecci\u00f3n del asistente de configuraci\u00f3n. La autenticaci\u00f3n puede ser omitida y un usuario puede visualizar la informaci\u00f3n como administrador al navegar manualmente al asistente de configuraci\u00f3n y forzarlo a redirigir a la p\u00e1gina deseada.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:trendnet:tew-827dru_firmware:2.08b01:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C008C1E-18D3-4A0C-97A1-89009310C55B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:trendnet:tew-827dru:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA6A79A7-46A7-446F-B512-4C75B5C214CE\"}]}]}],\"references\":[{\"url\":\"https://www.tenable.com/security/research/tra-2021-54\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Mitigation\",\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.