CVE-2021-20600 (GCVE-0-2021-20600)

Vulnerability from cvelistv5 – Published: 2021-10-08 16:42 – Updated: 2024-08-03 17:45
VLAI?
Summary
Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions "16" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending a large number of packets in a short time while the module starting up. System reset is required for recovery.
Severity ?
No CVSS data available.
CWE
  • Uncontrolled Resource Consumption
Assigner
Impacted products
Vendor Product Version
n/a Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Affected: Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions "16" and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:45:44.694Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-015_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU94914666/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions \"16\" and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions \"16\" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending a large number of packets in a short time while the module starting up. System reset is required for recovery."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-07T15:50:22",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-015_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/vu/JVNVU94914666/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
          "ID": "CVE-2021-20600",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions \"16\" and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions \"16\" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending a large number of packets in a short time while the module starting up. System reset is required for recovery."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-015_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-015_en.pdf"
            },
            {
              "name": "https://jvn.jp/vu/JVNVU94914666/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/vu/JVNVU94914666/index.html"
            },
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-04",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2021-20600",
    "datePublished": "2021-10-08T16:42:10",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:45:44.694Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:mitsubishielectric:r12ccpu-v_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"16\", \"matchCriteriaId\": \"B011D41D-5119-403C-A0A6-C872DA1ABB54\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:mitsubishielectric:r12ccpu-v:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8B938943-DDD5-43DC-98A3-29D0E6AFBF85\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions \\\"16\\\" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending a large number of packets in a short time while the module starting up. System reset is required for recovery.\"}, {\"lang\": \"es\", \"value\": \"El consumo incontrolado de recursos en el m\\u00f3dulo controlador C de la serie MELSEC iQ-R de Mitsubishi Electric R12CCPU-V, versiones de firmware \\\"16\\\" y anteriores, permite que un atacante remoto no autenticado provoque una condici\\u00f3n de denegaci\\u00f3n de servicio (DoS) mediante el env\\u00edo de un gran n\\u00famero de paquetes en poco tiempo durante el arranque del m\\u00f3dulo. Se requiere un reinicio del sistema para la recuperaci\\u00f3n\"}]",
      "id": "CVE-2021-20600",
      "lastModified": "2024-11-21T05:46:51.480",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 5.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:N/A:C\", \"baseScore\": 7.1, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-10-08T17:15:07.437",
      "references": "[{\"url\": \"https://jvn.jp/vu/JVNVU94914666/index.html\", \"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-280-04\", \"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-015_en.pdf\", \"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU94914666/index.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-280-04\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-015_en.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-400\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-20600\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2021-10-08T17:15:07.437\",\"lastModified\":\"2024-11-21T05:46:51.480\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions \\\"16\\\" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending a large number of packets in a short time while the module starting up. System reset is required for recovery.\"},{\"lang\":\"es\",\"value\":\"El consumo incontrolado de recursos en el m\u00f3dulo controlador C de la serie MELSEC iQ-R de Mitsubishi Electric R12CCPU-V, versiones de firmware \\\"16\\\" y anteriores, permite que un atacante remoto no autenticado provoque una condici\u00f3n de denegaci\u00f3n de servicio (DoS) mediante el env\u00edo de un gran n\u00famero de paquetes en poco tiempo durante el arranque del m\u00f3dulo. Se requiere un reinicio del sistema para la recuperaci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:N/A:C\",\"baseScore\":7.1,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:r12ccpu-v_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16\",\"matchCriteriaId\":\"B011D41D-5119-403C-A0A6-C872DA1ABB54\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:r12ccpu-v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B938943-DDD5-43DC-98A3-29D0E6AFBF85\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU94914666/index.html\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-280-04\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-015_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/vu/JVNVU94914666/index.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-280-04\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-015_en.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…