CVE-2021-21588 (GCVE-0-2021-21588)
Vulnerability from cvelistv5 – Published: 2021-07-12 15:40 – Updated: 2024-09-17 00:15
VLAI
Summary
Dell EMC PowerFlex, v3.5.x contain a Cross-Site WebSocket Hijacking Vulnerability in the Presentation Server/WebUI. An unauthenticated attacker could potentially exploit this vulnerability by tricking the user into performing unwanted actions on the Presentation Server and perform which may lead to configuration changes.
Severity
6.5 (Medium)
CWE
- CWE-345 - Insufficient Verification of Data Authenticity
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/000189265 | x_refsource_MISC |
Date Public
2021-07-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:23.581Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000189265"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PowerFlex",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "3.5.x"
}
]
}
],
"datePublic": "2021-07-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC PowerFlex, v3.5.x contain a Cross-Site WebSocket Hijacking Vulnerability in the Presentation Server/WebUI. An unauthenticated attacker could potentially exploit this vulnerability by tricking the user into performing unwanted actions on the Presentation Server and perform which may lead to configuration changes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345: Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-12T15:40:14.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000189265"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-07-01",
"ID": "CVE-2021-21588",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerFlex",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "3.5.x"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC PowerFlex, v3.5.x contain a Cross-Site WebSocket Hijacking Vulnerability in the Presentation Server/WebUI. An unauthenticated attacker could potentially exploit this vulnerability by tricking the user into performing unwanted actions on the Presentation Server and perform which may lead to configuration changes."
}
]
},
"impact": {
"cvss": {
"baseScore": 6.5,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-345: Insufficient Verification of Data Authenticity"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000189265",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000189265"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21588",
"datePublished": "2021-07-12T15:40:14.345Z",
"dateReserved": "2021-01-04T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:15:37.249Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-21588",
"date": "2026-06-12",
"epss": "0.00138",
"percentile": "0.33796"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:dell:powerflex_presentation_server:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"3.5\", \"versionEndExcluding\": \"3.6\", \"matchCriteriaId\": \"AD01330D-3605-4E13-B88C-485FBB6B7D15\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Dell EMC PowerFlex, v3.5.x contain a Cross-Site WebSocket Hijacking Vulnerability in the Presentation Server/WebUI. An unauthenticated attacker could potentially exploit this vulnerability by tricking the user into performing unwanted actions on the Presentation Server and perform which may lead to configuration changes.\"}, {\"lang\": \"es\", \"value\": \"Dell EMC PowerFlex, versiones v3.5.x, contiene una Vulnerabilidad de tipo Cross-site WebSocket Hijacking en la Presentaci\\u00f3n del Servidor/Interfaz de Usuario Web. Un atacante no autenticado podr\\u00eda potencialmente explotar esta vulnerabilidad al enga\\u00f1ar al usuario para realizar acciones no deseadas en el Servidor de Presentaci\\u00f3n y llevar a cabo lo que puede conllevar a cambios de configuraci\\u00f3n\"}]",
"id": "CVE-2021-21588",
"lastModified": "2024-11-21T05:48:39.423",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N\", \"baseScore\": 4.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 1.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2021-07-12T16:15:08.593",
"references": "[{\"url\": \"https://www.dell.com/support/kbdoc/000189265\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.dell.com/support/kbdoc/000189265\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-345\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-345\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-21588\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2021-07-12T16:15:08.593\",\"lastModified\":\"2024-11-21T05:48:39.423\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell EMC PowerFlex, v3.5.x contain a Cross-Site WebSocket Hijacking Vulnerability in the Presentation Server/WebUI. An unauthenticated attacker could potentially exploit this vulnerability by tricking the user into performing unwanted actions on the Presentation Server and perform which may lead to configuration changes.\"},{\"lang\":\"es\",\"value\":\"Dell EMC PowerFlex, versiones v3.5.x, contiene una Vulnerabilidad de tipo Cross-site WebSocket Hijacking en la Presentaci\u00f3n del Servidor/Interfaz de Usuario Web. Un atacante no autenticado podr\u00eda potencialmente explotar esta vulnerabilidad al enga\u00f1ar al usuario para realizar acciones no deseadas en el Servidor de Presentaci\u00f3n y llevar a cabo lo que puede conllevar a cambios de configuraci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-345\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-345\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerflex_presentation_server:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.5\",\"versionEndExcluding\":\"3.6\",\"matchCriteriaId\":\"AD01330D-3605-4E13-B88C-485FBB6B7D15\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/000189265\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/000189265\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…