CVE-2021-22794 (GCVE-0-2021-22794)
Vulnerability from cvelistv5 – Published: 2022-03-28 16:25 – Updated: 2024-08-03 18:51- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | StruxureWare Data Center Expert |
Affected:
unspecified , < V7.8.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.441Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "StruxureWare Data Center Expert",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V7.8.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-28T16:25:21.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22794",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "StruxureWare Data Center Expert",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "V7.8.1"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22794",
"datePublished": "2022-03-28T16:25:21.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.441Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-22794",
"date": "2026-05-27",
"epss": "0.03731",
"percentile": "0.88154"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"7.8.1\", \"matchCriteriaId\": \"D7773EA4-29BE-4527-A5E6-5271C15D8F60\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)\"}, {\"lang\": \"es\", \"value\": \"Una CWE-22: Se presenta una vulnerabilidad de Limitaci\\u00f3n de un Nombre de Ruta a un Directorio Restringido (\\\"Salto de Ruta \\\") que podr\\u00eda causar una ejecuci\\u00f3n de c\\u00f3digo remota. Producto afectado: StruxureWare Data Center Expert (versiones V7.8.1 y anteriores)\"}]",
"id": "CVE-2021-22794",
"lastModified": "2024-11-21T05:50:41.060",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 9.1, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 6.0}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-04-13T16:15:09.257",
"references": "[{\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2021-257-03/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2021-257-03/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-22\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-22794\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-04-13T16:15:09.257\",\"lastModified\":\"2024-11-21T05:50:41.060\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)\"},{\"lang\":\"es\",\"value\":\"Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n de un Nombre de Ruta a un Directorio Restringido (\\\"Salto de Ruta \\\") que podr\u00eda causar una ejecuci\u00f3n de c\u00f3digo remota. Producto afectado: StruxureWare Data Center Expert (versiones V7.8.1 y anteriores)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.3,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.8.1\",\"matchCriteriaId\":\"D7773EA4-29BE-4527-A5E6-5271C15D8F60\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2021-257-03/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2021-257-03/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
CERTFR-2021-AVI-705
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Modicon Premium processors with integrated Ethernet COPRO: TSXP574634, TSXP575634, TSXP576634 toutes versions | ||
| N/A | N/A | Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 toutes versions | ||
| Schneider Electric | N/A | EGX150/Link150 Ethernet Gateway versions antérieures à v5.1.24 | ||
| Schneider Electric | Modicon M340 | Modicon M340 Ethernet Communication modules BMXNOE0100 et BMXNOE0110 (H) toutes versions | ||
| Schneider Electric | N/A | Modicon Quantum processors with integrated Ethernet COPRO 140CPU65xxxxx toutes versions | ||
| Schneider Electric | N/A | Conext™ ComBox toutes versions | ||
| Schneider Electric | Modicon M340 | Modicon M340 X80 Ethernet Communication modules BMXNOR0200H RTU versions antérieures à v1.70 IR23 | ||
| Schneider Electric | Modicon M340 | Modicon M340 CPU BMXP34 versions antérieures à v3.40 | ||
| Schneider Electric | N/A | Acti9 Smartlink SI D toutes versions | ||
| Schneider Electric | Modicon M340 | Modicon M340 Ethernet TCP/IP network module BMXNOC0401 toutes versions | ||
| Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à v7.8.1 | ||
| Schneider Electric | N/A | Modicon Quantum Communication Modules: 140NOC78x00, 140NOC77101, 140NOE771x1 toutes versions |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon Premium processors with integrated Ethernet COPRO: TSXP574634, TSXP575634, TSXP576634 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EGX150/Link150 Ethernet Gateway versions ant\u00e9rieures \u00e0 v5.1.24",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 Ethernet Communication modules BMXNOE0100 et BMXNOE0110 (H) toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum processors with integrated Ethernet COPRO 140CPU65xxxxx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Conext\u2122 ComBox toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 X80 Ethernet Communication modules BMXNOR0200H RTU versions ant\u00e9rieures \u00e0 v1.70 IR23",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 CPU BMXP34 versions ant\u00e9rieures \u00e0 v3.40",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Acti9 Smartlink SI D toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 Ethernet TCP/IP network module BMXNOC0401 toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 v7.8.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum Communication Modules: 140NOC78x00, 140NOC77101, 140NOE771x1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-22795",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22795"
},
{
"name": "CVE-2020-27336",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27336"
},
{
"name": "CVE-2021-22797",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22797"
},
{
"name": "CVE-2020-27337",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27337"
},
{
"name": "CVE-2021-22794",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22794"
},
{
"name": "CVE-2020-27338",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27338"
},
{
"name": "CVE-2021-22788",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22788"
},
{
"name": "CVE-2021-22798",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22798"
},
{
"name": "CVE-2021-22787",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22787"
},
{
"name": "CVE-2021-22785",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22785"
}
],
"links": [],
"reference": "CERTFR-2021-AVI-705",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-09-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-03 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-01 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2020-353-01 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-353-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-02 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-04 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-04"
}
]
}
CERTFR-2021-AVI-705
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Modicon Premium processors with integrated Ethernet COPRO: TSXP574634, TSXP575634, TSXP576634 toutes versions | ||
| N/A | N/A | Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 toutes versions | ||
| Schneider Electric | N/A | EGX150/Link150 Ethernet Gateway versions antérieures à v5.1.24 | ||
| Schneider Electric | Modicon M340 | Modicon M340 Ethernet Communication modules BMXNOE0100 et BMXNOE0110 (H) toutes versions | ||
| Schneider Electric | N/A | Modicon Quantum processors with integrated Ethernet COPRO 140CPU65xxxxx toutes versions | ||
| Schneider Electric | N/A | Conext™ ComBox toutes versions | ||
| Schneider Electric | Modicon M340 | Modicon M340 X80 Ethernet Communication modules BMXNOR0200H RTU versions antérieures à v1.70 IR23 | ||
| Schneider Electric | Modicon M340 | Modicon M340 CPU BMXP34 versions antérieures à v3.40 | ||
| Schneider Electric | N/A | Acti9 Smartlink SI D toutes versions | ||
| Schneider Electric | Modicon M340 | Modicon M340 Ethernet TCP/IP network module BMXNOC0401 toutes versions | ||
| Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à v7.8.1 | ||
| Schneider Electric | N/A | Modicon Quantum Communication Modules: 140NOC78x00, 140NOC77101, 140NOE771x1 toutes versions |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon Premium processors with integrated Ethernet COPRO: TSXP574634, TSXP575634, TSXP576634 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EGX150/Link150 Ethernet Gateway versions ant\u00e9rieures \u00e0 v5.1.24",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 Ethernet Communication modules BMXNOE0100 et BMXNOE0110 (H) toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum processors with integrated Ethernet COPRO 140CPU65xxxxx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Conext\u2122 ComBox toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 X80 Ethernet Communication modules BMXNOR0200H RTU versions ant\u00e9rieures \u00e0 v1.70 IR23",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 CPU BMXP34 versions ant\u00e9rieures \u00e0 v3.40",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Acti9 Smartlink SI D toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 Ethernet TCP/IP network module BMXNOC0401 toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 v7.8.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum Communication Modules: 140NOC78x00, 140NOC77101, 140NOE771x1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-22795",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22795"
},
{
"name": "CVE-2020-27336",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27336"
},
{
"name": "CVE-2021-22797",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22797"
},
{
"name": "CVE-2020-27337",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27337"
},
{
"name": "CVE-2021-22794",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22794"
},
{
"name": "CVE-2020-27338",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27338"
},
{
"name": "CVE-2021-22788",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22788"
},
{
"name": "CVE-2021-22798",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22798"
},
{
"name": "CVE-2021-22787",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22787"
},
{
"name": "CVE-2021-22785",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22785"
}
],
"links": [],
"reference": "CERTFR-2021-AVI-705",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-09-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-03 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-01 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2020-353-01 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-353-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-02 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-04 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-04"
}
]
}
FKIE_CVE-2021-22794
Vulnerability from fkie_nvd - Published: 2022-04-13 16:15 - Updated: 2024-11-21 05:509.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | struxureware_data_center_expert | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7773EA4-29BE-4527-A5E6-5271C15D8F60",
"versionEndIncluding": "7.8.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)"
},
{
"lang": "es",
"value": "Una CWE-22: Se presenta una vulnerabilidad de Limitaci\u00f3n de un Nombre de Ruta a un Directorio Restringido (\"Salto de Ruta \") que podr\u00eda causar una ejecuci\u00f3n de c\u00f3digo remota. Producto afectado: StruxureWare Data Center Expert (versiones V7.8.1 y anteriores)"
}
],
"id": "CVE-2021-22794",
"lastModified": "2024-11-21T05:50:41.060",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 6.0,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-13T16:15:09.257",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
GHSA-C53Q-88XR-X99V
Vulnerability from github – Published: 2022-04-14 00:00 – Updated: 2022-04-21 00:00A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
{
"affected": [],
"aliases": [
"CVE-2021-22794"
],
"database_specific": {
"cwe_ids": [
"CWE-22"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-04-13T16:15:00Z",
"severity": "CRITICAL"
},
"details": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)",
"id": "GHSA-c53q-88xr-x99v",
"modified": "2022-04-21T00:00:38Z",
"published": "2022-04-14T00:00:18Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-22794"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2021-22794
Vulnerability from gsd - Updated: 2023-12-13 01:23{
"GSD": {
"alias": "CVE-2021-22794",
"description": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)",
"id": "GSD-2021-22794"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-22794"
],
"details": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)",
"id": "GSD-2021-22794",
"modified": "2023-12-13T01:23:24.725929Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22794",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "StruxureWare Data Center Expert",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "V7.8.1"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.8.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22794"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-04-20T19:20Z",
"publishedDate": "2022-04-13T16:15Z"
}
}
}
ICSA-21-257-03
Vulnerability from csaf_cisa - Published: 2021-09-14 00:00 - Updated: 2021-09-14 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Struxureware Data Center: Expert Versions 7.8.1 and prior
Schneider Electric Software, LLC / Struxureware Data Center
|
<= 7.8.1 |
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Struxureware Data Center: Expert Versions 7.8.1 and prior
Schneider Electric Software, LLC / Struxureware Data Center
|
<= 7.8.1 |
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
fix
|
{
"document": {
"acknowledgments": [
{
"names": [
"David Yesland"
],
"organization": "Trend Micro \u0027s Zero Day Initiative",
"summary": "reporting these vulnerabilities to Schneider Electric"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow remote code execution.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Energy, Food and Agriculture, Government Facilities, Transportation Systems, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-21-257-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-257-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-257-03 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-257-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric Struxureware Data Center Expert",
"tracking": {
"current_release_date": "2021-09-14T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-257-03",
"initial_release_date": "2021-09-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-09-14T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-21-257-03 Schneider Electric Struxureware Data Center Expert"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 7.8.1",
"product": {
"name": "Struxureware Data Center: Expert Versions 7.8.1 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Struxureware Data Center"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-22795",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The affected product is vulnerable to an OS command injection, which may allow an attacker to remotely execute code over the network.CVE-2021-22795 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22795"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has established a remediation plan for future versions of StruxureWare Data Center Expert to fix these vulnerabilities. Until the fix is released, users should immediately follow the security hardening guidelines found in Schneider Electric\u0027s Data Center Expert Security Handbook to reduce the risk of exploit.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook"
},
{
"category": "mitigation",
"details": "Schneider Electric has released security advisory SEVD-2021-257-03 in response to these vulnerabilities.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-03"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Install physical controls so no unauthorized personnel can access industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Place all controllers in locked cabinets and never leave them in \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Limit software updates to only those networks where devices targeted by the software updates reside.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Scan all methods of mobile data exchange with the isolated network (e.g., CDs, USB drives, etc.) before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Do not allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and systems, and ensure they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information, refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "mitigation",
"details": "For more details and assistance on how to protect a user\u0027s installation, contact the local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/work/solutions/cybersecurity/"
},
{
"category": "mitigation",
"details": "For further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/us/en/work/support/cybersecurity/overview.jsp"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2021-22794",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The affected product is vulnerable to directory traversal, which may allow an attacker to remotely execute code.CVE-2021-22794 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22794"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has established a remediation plan for future versions of StruxureWare Data Center Expert to fix these vulnerabilities. Until the fix is released, users should immediately follow the security hardening guidelines found in Schneider Electric\u0027s Data Center Expert Security Handbook to reduce the risk of exploit.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook"
},
{
"category": "mitigation",
"details": "Schneider Electric has released security advisory SEVD-2021-257-03 in response to these vulnerabilities.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-03"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Install physical controls so no unauthorized personnel can access industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Place all controllers in locked cabinets and never leave them in \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Limit software updates to only those networks where devices targeted by the software updates reside.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Scan all methods of mobile data exchange with the isolated network (e.g., CDs, USB drives, etc.) before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Do not allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and systems, and ensure they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information, refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "mitigation",
"details": "For more details and assistance on how to protect a user\u0027s installation, contact the local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/work/solutions/cybersecurity/"
},
{
"category": "mitigation",
"details": "For further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/us/en/work/support/cybersecurity/overview.jsp"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
SEVD-2021-257-03
Vulnerability from csaf_se - Published: 2021-09-14 00:00 - Updated: 2021-09-14 00:00A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric StruxureWare Data Center Expert 7.8.1 and prior.
Schneider Electric / StruxureWare Data Center Expert
|
<=7.8.1 |
Mitigation
fix
|
A CWE-78:Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric StruxureWare Data Center Expert 7.8.1 and prior.
Schneider Electric / StruxureWare Data Center Expert
|
<=7.8.1 |
Mitigation
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its StruxureWare Data Center Expert product.\r\nStruxureWare Data Center Expert provides an efficient way for organizations to monitor and manage their company-wide multi-vendor physical infrastructure; power, cooling, security and environment.\r\nFailure to apply the mitigations provided below may risk remote code execution, which could result in downtime or outage.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "StruxureWare Data Center Expert - SEVD-2021-257-03 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-257-03_StruxureWare_Data_Center_Expert_Security_Notification.pdf"
},
{
"category": "self",
"summary": "StruxureWare Data Center Expert - SEVD-2021-257-03 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2021-257-03.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "StruxureWare Data Center Expert",
"tracking": {
"current_release_date": "2021-09-14T00:00:00.000Z",
"generator": {
"date": "2021-09-14T00:00:00.000Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2021-257-03",
"initial_release_date": "2021-09-14T00:00:00.000Z",
"revision_history": [
{
"date": "2021-09-14T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=7.8.1",
"product": {
"name": "Schneider Electric StruxureWare Data Center Expert 7.8.1 and prior.",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "StruxureWare Data Center Expert"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"David Yesland"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2021-22794",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has established a remediation plan for future versions of StruxureWare Data Center Expert that will include a fix for these vulnerabilities. We will update this document when the remediation is available. Until then, customers should immediately follow security hardening guidelines found in https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook to reduce the risk of exploit.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-22794"
},
{
"acknowledgments": [
{
"names": [
"David Yesland"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2021-22795",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-78:Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause remote code execution when performed over the network.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has established a remediation plan for future versions of StruxureWare Data Center Expert that will include a fix for these vulnerabilities. We will update this document when the remediation is available. Until then, customers should immediately follow security hardening guidelines found in https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook to reduce the risk of exploit.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://dcimsupport.ecostruxureit.com/hc/en-us/articles/360039289633-Data-Center-Expert-Security-Handbook"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-22795"
}
]
}
VAR-202109-1928
Vulnerability from variot - Updated: 2021-12-18 15:40This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric Struxureware Data Center Expert. Authentication is required to exploit this vulnerability.The specific flaw exists within the handling of firmware updates. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of root
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202109-1928",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "struxureware data center expert",
"scope": null,
"trust": 0.7,
"vendor": "schneider electric",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-1071"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "David Yesland",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202109-990"
},
{
"db": "ZDI",
"id": "ZDI-21-1071"
}
],
"trust": 1.3
},
"cve": "CVE-2021-22794",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/severity#"
},
"@id": "https://www.variotdbs.pl/ref/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2021-22794",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "CVE-2021-22794",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202109-990",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202109-990"
},
{
"db": "ZDI",
"id": "ZDI-21-1071"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric Struxureware Data Center Expert. Authentication is required to exploit this vulnerability.The specific flaw exists within the handling of firmware updates. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of root",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-1071"
},
{
"db": "VULMON",
"id": "CVE-2021-22794"
}
],
"trust": 0.72
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-22794",
"trust": 1.4
},
{
"db": "ZDI",
"id": "ZDI-21-1071",
"trust": 1.4
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-13077",
"trust": 0.7
},
{
"db": "MCAFEE",
"id": "SB20210",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2021.3095",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-21-257-03",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202109-990",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-22794",
"trust": 0.1
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202109-990"
},
{
"db": "VULMON",
"id": "CVE-2021-22794"
},
{
"db": "ZDI",
"id": "ZDI-21-1071"
}
]
},
"id": "VAR-202109-1928",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.1196509
},
"last_update_date": "2021-12-18T15:40:54.484000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Schneider Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-257-03"
},
{
"title": "Schneider Electric Struxureware Data Center Expert Repair measures for path traversal vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=162792"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202109-990"
},
{
"db": "ZDI",
"id": "ZDI-21-1071"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.3,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-257-03"
},
{
"trust": 0.7,
"url": "https://www.zerodayinitiative.com/advisories/zdi-21-1071/"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2021091511"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.3095"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202109-990"
},
{
"db": "VULMON",
"id": "CVE-2021-22794"
},
{
"db": "ZDI",
"id": "ZDI-21-1071"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNNVD",
"id": "CNNVD-202109-990"
},
{
"db": "VULMON",
"id": "CVE-2021-22794"
},
{
"db": "ZDI",
"id": "ZDI-21-1071"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-09-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202109-990"
},
{
"date": null,
"db": "VULMON",
"id": "CVE-2021-22794"
},
{
"date": "2021-09-15T00:00:00",
"db": "ZDI",
"id": "ZDI-21-1071"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-09-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202109-990"
},
{
"date": null,
"db": "VULMON",
"id": "CVE-2021-22794"
},
{
"date": "2021-09-15T00:00:00",
"db": "ZDI",
"id": "ZDI-21-1071"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202109-990"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric Struxureware Data Center Expert Directory Traversal Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-1071"
}
],
"trust": 0.7
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "path traversal",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202109-990"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.