Summary
Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | McAfee LLC | Endpoint Security (ENS) for Windows |
Version: 10.7.x < 10.7.0 February 2021 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T19:14:09.386Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Endpoint Security (ENS) for Windows", "vendor": "McAfee LLC", "versions": [ { "lessThan": "10.7.0 February 2021", "status": "affected", "version": "10.7.x", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Lockheed Martin Red Team" } ], "datePublic": "2021-02-10T00:00:00", "descriptions": [ { "lang": "en", "value": "Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-312", "description": "CWE-312: Cleartext storage of sensitive information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-02-10T09:10:14", "orgId": "01626437-bf8f-4d1c-912a-893b5eb04808", "shortName": "trellix" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345" } ], "source": { "discovery": "EXTERNAL" }, "title": "Clear text storage of sensitive Information in ENS", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@mcafee.com", "DATE_PUBLIC": "2021-02-10T00:00:00.000Z", "ID": "CVE-2021-23878", "STATE": "PUBLIC", "TITLE": "Clear text storage of sensitive Information in ENS" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Endpoint Security (ENS) for Windows", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "10.7.x", "version_value": "10.7.0 February 2021" } ] } } ] }, "vendor_name": "McAfee LLC" } ] } }, "credit": [ { "lang": "eng", "value": "Lockheed Martin Red Team" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-312: Cleartext storage of sensitive information" } ] } ] }, "references": { "reference_data": [ { "name": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345", "refsource": "CONFIRM", "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345" } ] }, "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808", "assignerShortName": "trellix", "cveId": "CVE-2021-23878", "datePublished": "2021-02-10T09:10:14.580381Z", "dateReserved": "2021-01-12T00:00:00", "dateUpdated": "2024-09-16T19:41:11.060Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mcafee:endpoint_security:*:*:*:*:*:windows:*:*\", \"versionEndExcluding\": \"10.7.0\", \"matchCriteriaId\": \"CA4CEE25-A297-4D69-8CF8-5425875B206A\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de almacenamiento en texto sin cifrar de informaci\\u00f3n confidencial en la memoria en McAfee Endpoint Security (ENS) para Windows versiones anteriores a 10.7.0, la actualizaci\\u00f3n de Febrero de 2021, permite a un usuario local visualizar la configuraci\\u00f3n y las credenciales de ENS por medio del acceso a la memoria del proceso despu\\u00e9s de que el administrador de ENS haya llevado a cabo acciones espec\\u00edficas.\u0026#xa0;Para explotar esto, el usuario local debe acceder a la ubicaci\\u00f3n de memoria relevante inmediatamente despu\\u00e9s de a un administrador de ENS haya realizado un cambio de configuraci\\u00f3n por medio de la consola en su m\\u00e1quina\"}]", "id": "CVE-2021-23878", "lastModified": "2024-11-21T05:51:59.373", "metrics": "{\"cvssMetricV31\": [{\"source\": \"trellixpsirt@trellix.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.3, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N\", \"baseScore\": 5.0, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.3, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:N/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}", "published": "2021-02-10T09:15:13.090", "references": "[{\"url\": \"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345\", \"source\": \"trellixpsirt@trellix.com\"}, {\"url\": \"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]", "sourceIdentifier": "trellixpsirt@trellix.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"trellixpsirt@trellix.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-312\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-312\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2021-23878\",\"sourceIdentifier\":\"trellixpsirt@trellix.com\",\"published\":\"2021-02-10T09:15:13.090\",\"lastModified\":\"2024-11-21T05:51:59.373\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de almacenamiento en texto sin cifrar de informaci\u00f3n confidencial en la memoria en McAfee Endpoint Security (ENS) para Windows versiones anteriores a 10.7.0, la actualizaci\u00f3n de Febrero de 2021, permite a un usuario local visualizar la configuraci\u00f3n y las credenciales de ENS por medio del acceso a la memoria del proceso despu\u00e9s de que el administrador de ENS haya llevado a cabo acciones espec\u00edficas.\u0026#xa0;Para explotar esto, el usuario local debe acceder a la ubicaci\u00f3n de memoria relevante inmediatamente despu\u00e9s de a un administrador de ENS haya realizado un cambio de configuraci\u00f3n por medio de la consola en su m\u00e1quina\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"trellixpsirt@trellix.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.3,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N\",\"baseScore\":5.0,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.3,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"trellixpsirt@trellix.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mcafee:endpoint_security:*:*:*:*:*:windows:*:*\",\"versionEndExcluding\":\"10.7.0\",\"matchCriteriaId\":\"CA4CEE25-A297-4D69-8CF8-5425875B206A\"}]}]}],\"references\":[{\"url\":\"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345\",\"source\":\"trellixpsirt@trellix.com\"},{\"url\":\"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.