GSD-2021-23878

Vulnerability from gsd - Updated: 2023-12-13 01:23
Details
Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2021-23878",
    "description": "Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine",
    "id": "GSD-2021-23878"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2021-23878"
      ],
      "details": "Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine",
      "id": "GSD-2021-23878",
      "modified": "2023-12-13T01:23:30.405213Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "psirt@mcafee.com",
        "DATE_PUBLIC": "2021-02-10T00:00:00.000Z",
        "ID": "CVE-2021-23878",
        "STATE": "PUBLIC",
        "TITLE": "Clear text storage of sensitive Information in ENS"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Endpoint Security (ENS) for Windows",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "10.7.x",
                          "version_value": "10.7.0 February 2021"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "McAfee LLC"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "Lockheed Martin Red Team"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-312: Cleartext storage of sensitive information"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345",
            "refsource": "CONFIRM",
            "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345"
          }
        ]
      },
      "source": {
        "discovery": "EXTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:mcafee:endpoint_security:*:*:*:*:*:windows:*:*",
                "cpe_name": [],
                "versionEndExcluding": "10.7.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@mcafee.com",
          "ID": "CVE-2021-23878"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345",
              "refsource": "CONFIRM",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          "exploitabilityScore": 8.6,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": true
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 1.3,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2021-02-16T18:23Z",
      "publishedDate": "2021-02-10T09:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…