cve-2021-25664
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-03 20:11
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:11:27.513Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-05"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-248289.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2017.02.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-835",
              "description": "CWE-835: Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-13T08:59:36.202Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-05"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-248289.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-25664",
    "datePublished": "2021-04-22T20:42:20",
    "dateReserved": "2021-01-21T00:00:00",
    "dateUpdated": "2024-08-03T20:11:27.513Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-25664\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-04-22T21:15:09.990\",\"lastModified\":\"2024-02-13T09:15:43.397\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Capital VSTAR (Versiones que incluyen la pila IPv6 afectada), Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a V2017.02.4), Nucleus ReadyStart V4 (Todas las versiones anteriores a V4.1.0), Nucleus Source Code (Versiones que incluyen la pila IPv6 afectada). La funci\u00f3n que procesa la cabecera de extensi\u00f3n Hop-by-Hop en los paquetes IPv6 y sus opciones carece de cualquier comprobaci\u00f3n contra el campo de longitud de la cabecera, lo que permite a los atacantes poner la funci\u00f3n en un bucle infinito suministrando valores de longitud arbitrarios\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-835\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:capital_vstar:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EEBF34F7-F37A-4FD1-957E-B2E5DEE7A778\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:nucleus_net:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FCA7385D-A947-4A5B-B0B8-6D6225466EDE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2017.02.4\",\"matchCriteriaId\":\"C2F36C9F-E4F4-4678-B82D-361F4818B66C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.0\",\"matchCriteriaId\":\"B35FDE44-BE25-431D-B2EE-195ACC5A606C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"53A38C64-612A-4BC5-83D5-D3FA1C90E0F7\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-248289.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-103-05\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...