CVE-2021-27893 (GCVE-0-2021-27893)
Vulnerability from cvelistv5
Published
2021-03-15 14:05
Modified
2024-08-03 21:33
Severity ?
EPSS score ?
Summary
SSH Tectia Client and Server before 6.4.19 on Windows allow local privilege escalation in nonstandard conditions. ConnectSecure on Windows is affected.
References
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T21:33:16.484Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://info.ssh.com/tectia-vulnerability-cve-2021-27893", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "n/a", vendor: "n/a", versions: [ { status: "affected", version: "n/a", }, ], }, ], descriptions: [ { lang: "en", value: "SSH Tectia Client and Server before 6.4.19 on Windows allow local privilege escalation in nonstandard conditions. ConnectSecure on Windows is affected.", }, ], problemTypes: [ { descriptions: [ { description: "n/a", lang: "en", type: "text", }, ], }, ], providerMetadata: { dateUpdated: "2021-03-15T14:18:51", orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca", shortName: "mitre", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://info.ssh.com/tectia-vulnerability-cve-2021-27893", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "cve@mitre.org", ID: "CVE-2021-27893", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "n/a", version: { version_data: [ { version_value: "n/a", }, ], }, }, ], }, vendor_name: "n/a", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "SSH Tectia Client and Server before 6.4.19 on Windows allow local privilege escalation in nonstandard conditions. ConnectSecure on Windows is affected.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "n/a", }, ], }, ], }, references: { reference_data: [ { name: "https://info.ssh.com/tectia-vulnerability-cve-2021-27893", refsource: "MISC", url: "https://info.ssh.com/tectia-vulnerability-cve-2021-27893", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca", assignerShortName: "mitre", cveId: "CVE-2021-27893", datePublished: "2021-03-15T14:05:44", dateReserved: "2021-03-02T00:00:00", dateUpdated: "2024-08-03T21:33:16.484Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { fkie_nvd: { configurations: "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ssh:tectia_client:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.4.19\", \"matchCriteriaId\": \"F19AD707-E08D-4D78-AE68-46806EBABE3B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ssh:tectia_connectsecure:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"058495B9-2E81-4400-9A70-8E58A623BA5D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ssh:tectia_server:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.4.19\", \"matchCriteriaId\": \"18B662B1-6336-41F2-A5CA-55E875E43718\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A2572D17-1DE6-457B-99CC-64AFD54487EA\"}]}]}]", descriptions: "[{\"lang\": \"en\", \"value\": \"SSH Tectia Client and Server before 6.4.19 on Windows allow local privilege escalation in nonstandard conditions. ConnectSecure on Windows is affected.\"}, {\"lang\": \"es\", \"value\": \"SSH Tectia Client and Server versiones anteriores a 6.4.19 en Windows, permiten una escalada de privilegios locales en condiciones no est\\u00e1ndar. ConnectSecure en Windows est\\u00e1 afectado\"}]", id: "CVE-2021-27893", lastModified: "2024-11-21T05:58:43.487", metrics: "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.0, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.0, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 4.4, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.4, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", published: "2021-03-15T15:15:15.837", references: "[{\"url\": \"https://info.ssh.com/tectia-vulnerability-cve-2021-27893\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://info.ssh.com/tectia-vulnerability-cve-2021-27893\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", sourceIdentifier: "cve@mitre.org", vulnStatus: "Modified", weaknesses: "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]", }, nvd: "{\"cve\":{\"id\":\"CVE-2021-27893\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-03-15T15:15:15.837\",\"lastModified\":\"2024-11-21T05:58:43.487\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"SSH Tectia Client and Server before 6.4.19 on Windows allow local privilege escalation in nonstandard conditions. ConnectSecure on Windows is affected.\"},{\"lang\":\"es\",\"value\":\"SSH Tectia Client and Server versiones anteriores a 6.4.19 en Windows, permiten una escalada de privilegios locales en condiciones no estándar. ConnectSecure en Windows está afectado\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.0,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.0,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":4.4,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.4,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ssh:tectia_client:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.4.19\",\"matchCriteriaId\":\"F19AD707-E08D-4D78-AE68-46806EBABE3B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ssh:tectia_connectsecure:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"058495B9-2E81-4400-9A70-8E58A623BA5D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ssh:tectia_server:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.4.19\",\"matchCriteriaId\":\"18B662B1-6336-41F2-A5CA-55E875E43718\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A2572D17-1DE6-457B-99CC-64AFD54487EA\"}]}]}],\"references\":[{\"url\":\"https://info.ssh.com/tectia-vulnerability-cve-2021-27893\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://info.ssh.com/tectia-vulnerability-cve-2021-27893\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.