CVE-2021-31833 (GCVE-0-2021-31833)

Vulnerability from cvelistv5 – Published: 2022-01-04 09:45 – Updated: 2024-08-03 23:10
VLAI?
Summary
Potential product security bypass vulnerability in McAfee Application and Change Control (MACC) prior to version 8.3.4 allows a locally logged in attacker to circumvent the application solidification protection provided by MACC, permitting them to run applications that would usually be prevented by MACC. This would require the attacker to rename the specified binary to match name of any configured updater and perform a specific set of steps, resulting in the renamed binary to be to run.
CWE
  • CWE-269 - – Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
McAfee,LLC McAfee Application and Change Control (MACC) Affected: unspecified , < 8.3.4 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.836Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10370"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "McAfee Application and Change Control (MACC)",
          "vendor": "McAfee,LLC",
          "versions": [
            {
              "lessThan": "8.3.4",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Potential product security bypass vulnerability in McAfee Application and Change Control (MACC) prior to version 8.3.4 allows a locally logged in attacker to circumvent the application solidification protection provided by MACC, permitting them to run applications that would usually be prevented by MACC. This would require the attacker to rename the specified binary to match name of any configured updater and perform a specific set of steps, resulting in the renamed binary to be to run."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 \u2013 Improper Privilege Management\t",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-04T09:45:12",
        "orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
        "shortName": "trellix"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10370"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@mcafee.com",
          "ID": "CVE-2021-31833",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "McAfee Application and Change Control (MACC)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.3.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "McAfee,LLC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Potential product security bypass vulnerability in McAfee Application and Change Control (MACC) prior to version 8.3.4 allows a locally logged in attacker to circumvent the application solidification protection provided by MACC, permitting them to run applications that would usually be prevented by MACC. This would require the attacker to rename the specified binary to match name of any configured updater and perform a specific set of steps, resulting in the renamed binary to be to run."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 \u2013 Improper Privilege Management\t"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10370",
              "refsource": "CONFIRM",
              "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10370"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
    "assignerShortName": "trellix",
    "cveId": "CVE-2021-31833",
    "datePublished": "2022-01-04T09:45:12",
    "dateReserved": "2021-04-27T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.836Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mcafee:application_and_change_control:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"8.3.4\", \"matchCriteriaId\": \"4D10C34B-6B10-4DD6-9710-FF0121AA3F87\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Potential product security bypass vulnerability in McAfee Application and Change Control (MACC) prior to version 8.3.4 allows a locally logged in attacker to circumvent the application solidification protection provided by MACC, permitting them to run applications that would usually be prevented by MACC. This would require the attacker to rename the specified binary to match name of any configured updater and perform a specific set of steps, resulting in the renamed binary to be to run.\"}, {\"lang\": \"es\", \"value\": \"Una posible vulnerabilidad de omisi\\u00f3n de la seguridad del producto en McAfee Application and Change Control (MACC) versiones anteriores a 8.3.4, permite a un atacante que haya iniciado una sesi\\u00f3n local omitir la protecci\\u00f3n de solidificaci\\u00f3n de aplicaciones proporcionada por MACC, permiti\\u00e9ndole ejecutar aplicaciones que normalmente ser\\u00edan impedidas por MACC. Esto requerir\\u00eda que el atacante renombrara el binario especificado para que coincidiera con el nombre de cualquier actualizador configurado y llevara a cabo un conjunto espec\\u00edfico de pasos, resultando en que el binario renombrado pudiera ejecutarse\"}]",
      "id": "CVE-2021-31833",
      "lastModified": "2024-11-21T06:06:19.177",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"trellixpsirt@trellix.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\", \"baseScore\": 7.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.2}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 4.6, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.9, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2022-01-04T10:15:07.977",
      "references": "[{\"url\": \"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10370\", \"source\": \"trellixpsirt@trellix.com\", \"tags\": [\"Broken Link\"]}, {\"url\": \"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10370\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Broken Link\"]}]",
      "sourceIdentifier": "trellixpsirt@trellix.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"trellixpsirt@trellix.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-269\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-31833\",\"sourceIdentifier\":\"trellixpsirt@trellix.com\",\"published\":\"2022-01-04T10:15:07.977\",\"lastModified\":\"2024-11-21T06:06:19.177\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Potential product security bypass vulnerability in McAfee Application and Change Control (MACC) prior to version 8.3.4 allows a locally logged in attacker to circumvent the application solidification protection provided by MACC, permitting them to run applications that would usually be prevented by MACC. This would require the attacker to rename the specified binary to match name of any configured updater and perform a specific set of steps, resulting in the renamed binary to be to run.\"},{\"lang\":\"es\",\"value\":\"Una posible vulnerabilidad de omisi\u00f3n de la seguridad del producto en McAfee Application and Change Control (MACC) versiones anteriores a 8.3.4, permite a un atacante que haya iniciado una sesi\u00f3n local omitir la protecci\u00f3n de solidificaci\u00f3n de aplicaciones proporcionada por MACC, permiti\u00e9ndole ejecutar aplicaciones que normalmente ser\u00edan impedidas por MACC. Esto requerir\u00eda que el atacante renombrara el binario especificado para que coincidiera con el nombre de cualquier actualizador configurado y llevara a cabo un conjunto espec\u00edfico de pasos, resultando en que el binario renombrado pudiera ejecutarse\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"trellixpsirt@trellix.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"trellixpsirt@trellix.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mcafee:application_and_change_control:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.3.4\",\"matchCriteriaId\":\"4D10C34B-6B10-4DD6-9710-FF0121AA3F87\"}]}]}],\"references\":[{\"url\":\"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10370\",\"source\":\"trellixpsirt@trellix.com\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10370\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…