cve-2021-33738
Vulnerability from cvelistv5
Published
2021-08-10 10:35
Modified
2024-08-03 23:58
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in JT2Go (All versions < V13.2.0.2), Teamcenter Visualization (All versions < V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf | Vendor Advisory | |
productcert@siemens.com | https://www.zerodayinitiative.com/advisories/ZDI-21-981/ | Third Party Advisory, VDB Entry |
Impacted products
▼ | Vendor | Product |
---|---|---|
Siemens | JT2Go | |
Siemens | Teamcenter Visualization |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:58:22.886Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "JT2Go", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.2.0.2" } ] }, { "product": "Teamcenter Visualization", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.2.0.2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T10:47:39", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-33738", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "JT2Go", "version": { "version_data": [ { "version_value": "All versions \u003c V13.2.0.2" } ] } }, { "product_name": "Teamcenter Visualization", "version": { "version_data": [ { "version_value": "All versions \u003c V13.2.0.2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-125: Out-of-bounds Read" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-33738", "datePublished": "2021-08-10T10:35:33", "dateReserved": "2021-05-28T00:00:00", "dateUpdated": "2024-08-03T23:58:22.886Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-33738\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-08-10T11:15:09.197\",\"lastModified\":\"2021-09-21T16:27:35.173\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2.0.2), Teamcenter Visualization (Todas las versiones anteriores a V13.2.0.2). La biblioteca plmxmlAdapterSE70.dll de las aplicaciones afectadas no comprueba apropiadamente los datos suministrados por el usuario cuando analiza los archivos PAR. Esto podr\u00eda resultar en una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante podr\u00eda aprovechar esta vulnerabilidad para filtrar informaci\u00f3n en el contexto del proceso actual. (ZDI-CAN-13405)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0.2\",\"matchCriteriaId\":\"FB703B83-3389-470A-B6D7-F8E6A2ACEC62\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0.2\",\"matchCriteriaId\":\"960C485F-738E-4E5C-ABA5-32E1A260C6A8\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-981/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.