Dell EMC PowerScale OneFS versions 8.2.x - 9.2.x contain an incorrect permission assignment for critical resource vulnerability. This could allow a user with ISI_PRIV_LOGIN_SSH or ISI_PRIV_LOGIN_CONSOLE to access privileged information about the cluster.
References
▼ | URL | Tags | |
---|---|---|---|
security_alert@emc.com | https://www.dell.com/support/kbdoc/000190408 | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Dell | PowerScale OneFS |
Version: 8.2.x - 9.2.x |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T00:54:50.760Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/000190408" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "PowerScale OneFS", "vendor": "Dell", "versions": [ { "status": "affected", "version": "8.2.x - 9.2.x" } ] } ], "datePublic": "2021-08-10T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC PowerScale OneFS versions 8.2.x - 9.2.x contain an incorrect permission assignment for critical resource vulnerability. This could allow a user with ISI_PRIV_LOGIN_SSH or ISI_PRIV_LOGIN_CONSOLE to access privileged information about the cluster." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732: Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-16T22:00:31", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/kbdoc/000190408" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2021-08-10", "ID": "CVE-2021-36279", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "PowerScale OneFS", "version": { "version_data": [ { "version_affected": "=", "version_value": "8.2.x - 9.2.x" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC PowerScale OneFS versions 8.2.x - 9.2.x contain an incorrect permission assignment for critical resource vulnerability. This could allow a user with ISI_PRIV_LOGIN_SSH or ISI_PRIV_LOGIN_CONSOLE to access privileged information about the cluster." } ] }, "impact": { "cvss": { "baseScore": 7.8, "baseSeverity": "High", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-732: Incorrect Permission Assignment for Critical Resource" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/kbdoc/000190408", "refsource": "MISC", "url": "https://www.dell.com/support/kbdoc/000190408" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2021-36279", "datePublished": "2021-08-16T22:00:31.572502Z", "dateReserved": "2021-07-08T00:00:00", "dateUpdated": "2024-09-16T23:05:55.859Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-36279\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2021-08-16T22:15:07.793\",\"lastModified\":\"2021-08-24T18:00:16.247\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell EMC PowerScale OneFS versions 8.2.x - 9.2.x contain an incorrect permission assignment for critical resource vulnerability. This could allow a user with ISI_PRIV_LOGIN_SSH or ISI_PRIV_LOGIN_CONSOLE to access privileged information about the cluster.\"},{\"lang\":\"es\",\"value\":\"Dell EMC PowerScale OneFS versiones 8.2.x - 9.2.x, contienen una asignaci\u00f3n de permisos incorrecta para la vulnerabilidad de los recursos cr\u00edticos. Esto podr\u00eda permitir a un usuario privilegiado ISI_PRIV_LOGIN_SSH o ISI_PRIV_LOGIN_CONSOLE acceder a informaci\u00f3n privilegiada sobre el cluster.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.1,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":7.2},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.0.0.0\",\"versionEndIncluding\":\"9.2.2.0\",\"matchCriteriaId\":\"5C66FB06-1497-4725-AC65-E8E884FA1782\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:8.2.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FF89B320-6D5A-4E46-A1FA-FCDB31F325C4\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/000190408\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.