Summary
A vulnerability has been identified in SINUMERIK 808D (All versions), SINUMERIK 828D (All versions < V4.95). Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | SINUMERIK 808D |
Version: All versions |
||||
|
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-04T01:16:03.969Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SINUMERIK 808D", vendor: "Siemens", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SINUMERIK 828D", vendor: "Siemens", versions: [ { status: "affected", version: "All versions < V4.95", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SINUMERIK 808D (All versions), SINUMERIK 828D (All versions < V4.95). Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-122", description: "CWE-122: Heap-based Buffer Overflow", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2021-10-12T09:49:37", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2021-37199", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SINUMERIK 808D", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SINUMERIK 828D", version: { version_data: [ { version_value: "All versions < V4.95", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SINUMERIK 808D (All versions), SINUMERIK 828D (All versions < V4.95). Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-122: Heap-based Buffer Overflow", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2021-37199", datePublished: "2021-10-12T09:49:37", dateReserved: "2021-07-21T00:00:00", dateUpdated: "2024-08-04T01:16:03.969Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { fkie_nvd: { configurations: "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:sinumerik_808d_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6656E410-ED0B-413E-A173-D21DA005123E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:sinumerik_808d:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6B6A9DDC-D9C6-4497-8948-295C4AB567DA\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.95\", \"matchCriteriaId\": \"2996DBE9-0573-4D62-A4E5-AE39F3A8978F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7D97047C-9772-4AEB-B993-131EBBAE33BA\"}]}]}]", descriptions: "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SINUMERIK 808D (All versions), SINUMERIK 828D (All versions < V4.95). Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en SINUMERIK 808D (Todas las versiones), SINUMERIK 828D (Todas las versiones anteriores a V4.95). Los dispositivos afectados no procesan correctamente determinados paquetes especialmente dise\\u00f1ados enviados al puerto 102/tcp, lo que podr\\u00eda permitir a un atacante causar una denegaci\\u00f3n de servicio en el dispositivo\"}]", id: "CVE-2021-37199", lastModified: "2024-11-21T06:14:50.767", metrics: "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:C\", \"baseScore\": 7.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", published: "2021-10-12T10:15:12.600", references: "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-122\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]", }, nvd: "{\"cve\":{\"id\":\"CVE-2021-37199\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-10-12T10:15:12.600\",\"lastModified\":\"2024-11-21T06:14:50.767\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINUMERIK 808D (All versions), SINUMERIK 828D (All versions < V4.95). Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINUMERIK 808D (Todas las versiones), SINUMERIK 828D (Todas las versiones anteriores a V4.95). Los dispositivos afectados no procesan correctamente determinados paquetes especialmente diseñados enviados al puerto 102/tcp, lo que podría permitir a un atacante causar una denegación de servicio en el dispositivo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:C\",\"baseScore\":7.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-122\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_808d_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6656E410-ED0B-413E-A173-D21DA005123E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_808d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6B6A9DDC-D9C6-4497-8948-295C4AB567DA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.95\",\"matchCriteriaId\":\"2996DBE9-0573-4D62-A4E5-AE39F3A8978F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7D97047C-9772-4AEB-B993-131EBBAE33BA\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.