SSA-178380

Vulnerability from csaf_siemens - Published: 2021-10-12 00:00 - Updated: 2021-10-12 00:00
Summary
SSA-178380: Denial-of-Service Vulnerability in SINUMERIK Controllers

Notes

Summary
A Denial-of-Service vulnerability found in SINUMERIK Controllers could allow an unauthenticated attacker with network access to the affected devices to cause system failure with total loss of availability. Siemens has released an update for the SINUMERIK 828D and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.

{
  "document": {
    "acknowledgments": [
      {
        "organization": "Industrial Control Security Laboratory of Qi An Xin Group Inc.",
        "summary": "reporting the vulnerability and coordination efforts"
      }
    ],
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "A Denial-of-Service vulnerability found in SINUMERIK Controllers could allow an unauthenticated attacker with network access to the affected devices to cause system failure with total loss of availability.\n\nSiemens has released an update for the SINUMERIK 828D and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-178380: Denial-of-Service Vulnerability in SINUMERIK Controllers - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-178380.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-178380: Denial-of-Service Vulnerability in SINUMERIK Controllers - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-178380.txt"
      },
      {
        "category": "self",
        "summary": "SSA-178380: Denial-of-Service Vulnerability in SINUMERIK Controllers - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-178380.json"
      }
    ],
    "title": "SSA-178380: Denial-of-Service Vulnerability in SINUMERIK Controllers",
    "tracking": {
      "current_release_date": "2021-10-12T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-178380",
      "initial_release_date": "2021-10-12T00:00:00Z",
      "revision_history": [
        {
          "date": "2021-10-12T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SINUMERIK 808D",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK 808D"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V4.95",
                "product": {
                  "name": "SINUMERIK 828D",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK 828D"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2021-37199",
      "cwe": {
        "id": "CWE-122",
        "name": "Heap-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-37199 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37199.json"
        }
      ],
      "remediations": [
        {
          "category": "none_available",
          "details": "Currently no remediation is available",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.95 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Restrict access to port 102/tcp to trusted systems e.g. with an external firewall",
          "product_ids": [
            "1",
            "2"
          ]
        },
        {
          "category": "workaround",
          "details": "Apply general workarounds.",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-37199"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…