Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | HPE Aruba Instant (IAP) |
Version: Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:23:01.639Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "HPE Aruba Instant (IAP)", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2" } ] } ], "descriptions": [ { "lang": "en", "value": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability." } ], "problemTypes": [ { "descriptions": [ { "description": "remote buffer overflow", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-11-09T12:06:15", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "security-alert@hpe.com", "ID": "CVE-2021-37726", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "HPE Aruba Instant (IAP)", "version": { "version_data": [ { "version_value": "Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "remote buffer overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt", "refsource": "MISC", "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0", "assignerShortName": "hpe", "cveId": "CVE-2021-37726", "datePublished": "2021-10-12T14:06:35", "dateReserved": "2021-07-29T00:00:00", "dateUpdated": "2024-08-04T01:23:01.639Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:arubanetworks:aruba_instant:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"8.7.0.0\", \"versionEndExcluding\": \"8.7.1.3\", \"matchCriteriaId\": \"9A9E47A0-EFDD-493A-A7C5-02A2A8897767\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_w1750d_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"8.7.1.3\", \"matchCriteriaId\": \"B4603220-61F1-4686-B55D-F9F5D27F324A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FBC30055-239F-4BB1-B2D1-E5E35F0D8911\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.\"}, {\"lang\": \"es\", \"value\": \"Se ha detectado una vulnerabilidad de desbordamiento de b\\u00fafer remoto en HPE Aruba Instant (IAP) versiones: Aruba Instant 8.7.x.x: 8.7.0.0 hasta 8.7.1.2. Aruba ha publicado parches para Aruba Instant (IAP) que abordan esta vulnerabilidad de seguridad\"}]", "id": "CVE-2021-37726", "lastModified": "2024-11-21T06:15:48.790", "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 10.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", "published": "2021-10-12T15:15:07.797", "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf\", \"source\": \"security-alert@hpe.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt\", \"source\": \"security-alert@hpe.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "security-alert@hpe.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-120\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2021-37726\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2021-10-12T15:15:07.797\",\"lastModified\":\"2024-11-21T06:15:48.790\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.\"},{\"lang\":\"es\",\"value\":\"Se ha detectado una vulnerabilidad de desbordamiento de b\u00fafer remoto en HPE Aruba Instant (IAP) versiones: Aruba Instant 8.7.x.x: 8.7.0.0 hasta 8.7.1.2. Aruba ha publicado parches para Aruba Instant (IAP) que abordan esta vulnerabilidad de seguridad\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:arubanetworks:aruba_instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.7.0.0\",\"versionEndExcluding\":\"8.7.1.3\",\"matchCriteriaId\":\"9A9E47A0-EFDD-493A-A7C5-02A2A8897767\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_w1750d_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.7.1.3\",\"matchCriteriaId\":\"B4603220-61F1-4686-B55D-F9F5D27F324A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FBC30055-239F-4BB1-B2D1-E5E35F0D8911\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
var-202110-1635
Vulnerability from variot
A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability. Aruba Instant Exists in a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Provides the only Wi-Fi solution that is easy to set up. A remote attacker can use this vulnerability to execute arbitrary code on the target system
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202110-1635", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance w1750d", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.7.1.3" }, { "model": "aruba instant", "scope": "lt", "trust": 1.0, "vendor": "arubanetworks", "version": "8.7.1.3" }, { "model": "aruba instant", "scope": "gte", "trust": 1.0, "vendor": "arubanetworks", "version": "8.7.0.0" }, { "model": "scalance w1750d", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "aruba instant", "scope": null, "trust": 0.8, "vendor": "\u30a2\u30eb\u30d0\u30cd\u30c3\u30c8\u30ef\u30fc\u30af\u30b9\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "networks aruba instant", "scope": "eq", "trust": 0.6, "vendor": "aruba", "version": "8.7.x.x" }, { "model": "networks aruba instant", "scope": "gte", "trust": 0.6, "vendor": "aruba", "version": "8.7.0.0,\u003c=8.7.1.2" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-89448" }, { "db": "JVNDB", "id": "JVNDB-2021-013713" }, { "db": "NVD", "id": "CVE-2021-37726" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:arubanetworks:aruba_instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.7.1.3", "versionStartIncluding": "8.7.0.0", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_w1750d_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.7.1.3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-37726" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202110-447" } ], "trust": 0.6 }, "cve": "CVE-2021-37726", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-37726", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-89448", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-37726", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-37726", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2021-89448", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202110-447", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-37726", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-89448" }, { "db": "VULMON", "id": "CVE-2021-37726" }, { "db": "JVNDB", "id": "JVNDB-2021-013713" }, { "db": "NVD", "id": "CVE-2021-37726" }, { "db": "CNNVD", "id": "CNNVD-202110-447" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability. Aruba Instant Exists in a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Provides the only Wi-Fi solution that is easy to set up. A remote attacker can use this vulnerability to execute arbitrary code on the target system", "sources": [ { "db": "NVD", "id": "CVE-2021-37726" }, { "db": "JVNDB", "id": "JVNDB-2021-013713" }, { "db": "CNVD", "id": "CNVD-2021-89448" }, { "db": "VULMON", "id": "CVE-2021-37726" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-37726", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-917476", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-21-315-06", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU95671889", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-013713", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-89448", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021111004", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021100720", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.3874", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202110-447", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-37726", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-89448" }, { "db": "VULMON", "id": "CVE-2021-37726" }, { "db": "JVNDB", "id": "JVNDB-2021-013713" }, { "db": "NVD", "id": "CVE-2021-37726" }, { "db": "CNNVD", "id": "CNNVD-202110-447" } ] }, "id": "VAR-202110-1635", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-89448" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-89448" } ] }, "last_update_date": "2023-12-18T11:02:33.353000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "ARUBA-PSA-2021-017 Siemens Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://www.arubanetworks.com/assets/alert/aruba-psa-2021-017.txt" }, { "title": "Patch for Aruba Instant buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/300096" }, { "title": "Aruba Instant Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=166510" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=3a4aac694122a77f4f689c8a03f6ae75" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-89448" }, { "db": "VULMON", "id": "CVE-2021-37726" }, { "db": "JVNDB", "id": "JVNDB-2021-013713" }, { "db": "CNNVD", "id": "CNNVD-202110-447" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-013713" }, { "db": "NVD", "id": "CVE-2021-37726" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-37726" }, { "trust": 1.7, "url": "https://www.arubanetworks.com/assets/alert/aruba-psa-2021-017.txt" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" }, { "trust": 0.9, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-315-06" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu95671889/index.html" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021111004" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.3874" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-315-06" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021100720" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/120.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-89448" }, { "db": "VULMON", "id": "CVE-2021-37726" }, { "db": "JVNDB", "id": "JVNDB-2021-013713" }, { "db": "NVD", "id": "CVE-2021-37726" }, { "db": "CNNVD", "id": "CNNVD-202110-447" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-89448" }, { "db": "VULMON", "id": "CVE-2021-37726" }, { "db": "JVNDB", "id": "JVNDB-2021-013713" }, { "db": "NVD", "id": "CVE-2021-37726" }, { "db": "CNNVD", "id": "CNNVD-202110-447" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-11-20T00:00:00", "db": "CNVD", "id": "CNVD-2021-89448" }, { "date": "2021-10-12T00:00:00", "db": "VULMON", "id": "CVE-2021-37726" }, { "date": "2022-09-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-013713" }, { "date": "2021-10-12T15:15:07.797000", "db": "NVD", "id": "CVE-2021-37726" }, { "date": "2021-10-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202110-447" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-11-20T00:00:00", "db": "CNVD", "id": "CNVD-2021-89448" }, { "date": "2021-11-24T00:00:00", "db": "VULMON", "id": "CVE-2021-37726" }, { "date": "2022-09-27T02:11:00", "db": "JVNDB", "id": "JVNDB-2021-013713" }, { "date": "2021-11-24T21:31:16.563000", "db": "NVD", "id": "CVE-2021-37726" }, { "date": "2021-11-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202110-447" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202110-447" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Aruba\u00a0Instant\u00a0 Classic buffer overflow vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-013713" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202110-447" } ], "trust": 0.6 } }
icsa-21-315-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to execute code on the affected devices, read arbitrary files, or create a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet; Locate control system networks and remote devices behind firewalls and isolate them from the business network; When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-917476: Multiple Vulnerabilities in SCALANCE W1750D - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-917476.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-315-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-06 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-315-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-917476: Multiple Vulnerabilities in SCALANCE W1750D - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" }, { "category": "external", "summary": "SSA-917476: Multiple Vulnerabilities in SCALANCE W1750D - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-917476.txt" } ], "title": "Siemens SCALANCE W1750D", "tracking": { "current_release_date": "2022-11-11T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-315-06", "initial_release_date": "2021-11-11T00:00:00.000000Z", "revision_history": [ { "date": "2021-11-11T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-315-06 Siemens SCALANCE W1750D" }, { "date": "2022-10-13T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "Siemens SCALANCE W1750D (Update A)" }, { "date": "2022-11-11T00:00:00.000000Z", "legacy_version": "B", "number": "3", "summary": "Siemens SCALANCE W1750D (Update B)" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V8.7.1.3", "product": { "name": "SCALANCE W1750D", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "\u003e= V8.7.1.3 \u003c V8.7.1.9", "product": { "name": "SCALANCE W1750D", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SCALANCE W1750D" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-37726", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP). Successful exploitation could allow for unauthenticated remote code execution, potentially resulting in the execution of arbitrary code as a privileged user on the underlying system. CVE-2021-37726 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37726" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37726" }, { "cve": "CVE-2021-37727", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant (IAP) command line interface. If exploited, it could result in the ability to execute arbitrary commands as a privileged user on the underlying OS, potentially compromising the system. CVE-2021-37727 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37727" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "vendor_fix", "details": "Update to V8.7.1.9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109813747/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-37727" }, { "cve": "CVE-2021-37730", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant (IAP) command line interface. If exploited, it could result in the ability to execute arbitrary commands as a privileged user on the underlying OS, potentially compromising the system. CVE-2021-37730 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37730" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "vendor_fix", "details": "Update to V8.7.1.9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109813747/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-37730" }, { "cve": "CVE-2021-37732", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant (IAP) web-based management user interface. If exploited, it could result in the ability to execute arbitrary commands as a privileged user on the underlying OS, potentially compromising the system. CVE-2021-37732 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37732" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37732" }, { "cve": "CVE-2021-37734", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "An authenticated arbitrary file read access vulnerability was discovered in Aruba Instant Access Points. Successful exploitation could lead to an attacker reading any file off the underlying filesystem, including system sensitive files. CVE-2021-37734 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37734" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "vendor_fix", "details": "Update to V8.7.1.9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109813747/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-37734" }, { "cve": "CVE-2021-37735", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "A remote denial of service vulnerability was discovered in Aruba Instant through the command line interface. If an attacker exploits this, they could create a denial-of-service condition, leading ot a temporary loss of service, until the next reboot.\n CVE-2021-37735 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37735" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37735" } ] }
ICSA-21-315-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to execute code on the affected devices, read arbitrary files, or create a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet; Locate control system networks and remote devices behind firewalls and isolate them from the business network; When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-917476: Multiple Vulnerabilities in SCALANCE W1750D - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-917476.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-315-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-06 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-315-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-917476: Multiple Vulnerabilities in SCALANCE W1750D - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" }, { "category": "external", "summary": "SSA-917476: Multiple Vulnerabilities in SCALANCE W1750D - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-917476.txt" } ], "title": "Siemens SCALANCE W1750D", "tracking": { "current_release_date": "2022-11-11T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-315-06", "initial_release_date": "2021-11-11T00:00:00.000000Z", "revision_history": [ { "date": "2021-11-11T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-315-06 Siemens SCALANCE W1750D" }, { "date": "2022-10-13T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "Siemens SCALANCE W1750D (Update A)" }, { "date": "2022-11-11T00:00:00.000000Z", "legacy_version": "B", "number": "3", "summary": "Siemens SCALANCE W1750D (Update B)" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V8.7.1.3", "product": { "name": "SCALANCE W1750D", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "\u003e= V8.7.1.3 \u003c V8.7.1.9", "product": { "name": "SCALANCE W1750D", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SCALANCE W1750D" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-37726", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP). Successful exploitation could allow for unauthenticated remote code execution, potentially resulting in the execution of arbitrary code as a privileged user on the underlying system. CVE-2021-37726 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37726" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37726" }, { "cve": "CVE-2021-37727", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant (IAP) command line interface. If exploited, it could result in the ability to execute arbitrary commands as a privileged user on the underlying OS, potentially compromising the system. CVE-2021-37727 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37727" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "vendor_fix", "details": "Update to V8.7.1.9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109813747/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-37727" }, { "cve": "CVE-2021-37730", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant (IAP) command line interface. If exploited, it could result in the ability to execute arbitrary commands as a privileged user on the underlying OS, potentially compromising the system. CVE-2021-37730 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37730" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "vendor_fix", "details": "Update to V8.7.1.9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109813747/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-37730" }, { "cve": "CVE-2021-37732", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant (IAP) web-based management user interface. If exploited, it could result in the ability to execute arbitrary commands as a privileged user on the underlying OS, potentially compromising the system. CVE-2021-37732 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37732" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37732" }, { "cve": "CVE-2021-37734", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "An authenticated arbitrary file read access vulnerability was discovered in Aruba Instant Access Points. Successful exploitation could lead to an attacker reading any file off the underlying filesystem, including system sensitive files. CVE-2021-37734 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37734" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "vendor_fix", "details": "Update to V8.7.1.9 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109813747/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-37734" }, { "cve": "CVE-2021-37735", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "A remote denial of service vulnerability was discovered in Aruba Instant through the command line interface. If an attacker exploits this, they could create a denial-of-service condition, leading ot a temporary loss of service, until the next reboot.\n CVE-2021-37735 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37735" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.3 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109802805/" }, { "category": "workaround", "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access to the Aruba Instant web-based management interface from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Enabling the Enhanced PAPI Security feature where available will prevent exploitation of these vulnerabilities. Please contact TAC for assistance if needed", "product_ids": [ "CSAFPID-0001" ] }, { "category": "workaround", "details": "Block access for Aruba Instant device on port UDP/8211 from all untrusted users", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37735" } ] }
cve-2021-37726
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
arubanetworks | aruba_instant | * | |
siemens | scalance_w1750d_firmware | * | |
siemens | scalance_w1750d | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:arubanetworks:aruba_instant:*:*:*:*:*:*:*:*", "matchCriteriaId": "9A9E47A0-EFDD-493A-A7C5-02A2A8897767", "versionEndExcluding": "8.7.1.3", "versionStartIncluding": "8.7.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w1750d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4603220-61F1-4686-B55D-F9F5D27F324A", "versionEndExcluding": "8.7.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*", "matchCriteriaId": "FBC30055-239F-4BB1-B2D1-E5E35F0D8911", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad de desbordamiento de b\u00fafer remoto en HPE Aruba Instant (IAP) versiones: Aruba Instant 8.7.x.x: 8.7.0.0 hasta 8.7.1.2. Aruba ha publicado parches para Aruba Instant (IAP) que abordan esta vulnerabilidad de seguridad" } ], "id": "CVE-2021-37726", "lastModified": "2024-11-21T06:15:48.790", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-10-12T15:15:07.797", "references": [ { "source": "security-alert@hpe.com", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" }, { "source": "security-alert@hpe.com", "tags": [ "Vendor Advisory" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt" } ], "sourceIdentifier": "security-alert@hpe.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
ghsa-gmgh-mrc4-vrr5
Vulnerability from github
A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.
{ "affected": [], "aliases": [ "CVE-2021-37726" ], "database_specific": { "cwe_ids": [ "CWE-120" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-10-12T15:15:00Z", "severity": "CRITICAL" }, "details": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.", "id": "GHSA-gmgh-mrc4-vrr5", "modified": "2022-05-24T19:17:19Z", "published": "2022-05-24T19:17:19Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-37726" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" }, { "type": "WEB", "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt" } ], "schema_version": "1.4.0", "severity": [] }
gsd-2021-37726
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2021-37726", "description": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.", "id": "GSD-2021-37726" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-37726" ], "details": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.", "id": "GSD-2021-37726", "modified": "2023-12-13T01:23:09.983361Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "security-alert@hpe.com", "ID": "CVE-2021-37726", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "HPE Aruba Instant (IAP)", "version": { "version_data": [ { "version_value": "Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "remote buffer overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt", "refsource": "MISC", "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:arubanetworks:aruba_instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.7.1.3", "versionStartIncluding": "8.7.0.0", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_w1750d_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.7.1.3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "security-alert@hpe.com", "ID": "CVE-2021-37726" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-120" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2021-017.txt" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2021-11-24T21:31Z", "publishedDate": "2021-10-12T15:15Z" } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.