Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2021-42383
Vulnerability from cvelistv5
Published
2021-11-15 00:00
Modified
2024-08-04 03:30
Severity ?
EPSS score ?
Summary
A use-after-free in Busybox's awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T03:30:38.425Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://jfrog.com/blog/unboxing-busybox-14-new-vulnerabilities-uncovered-by-claroty-and-jfrog/" }, { "name": "FEDORA-2021-5a95823596", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/UQXGOGWBIYWOIVXJVRKHZR34UMEHQBXS/" }, { "name": "FEDORA-2021-c52c0fe490", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/6T2TURBYYJGBMQTTN2DSOAIQGP7WCPGV/" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20211223-0002/" }, { "tags": [ "x_transferred" ], "url": "https://claroty.com/team82/research/unboxing-busybox-14-vulnerabilities-uncovered-by-claroty-jfrog" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "busybox", "vendor": "busybox", "versions": [ { "lessThan": "1.34.0", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-416", "description": "CWE-416", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-25T00:00:00", "orgId": "48a46f29-ae42-4e1d-90dd-c1676c1e5e6d", "shortName": "JFROG" }, "references": [ { "url": "https://jfrog.com/blog/unboxing-busybox-14-new-vulnerabilities-uncovered-by-claroty-and-jfrog/" }, { "name": "FEDORA-2021-5a95823596", "tags": [ "vendor-advisory" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/UQXGOGWBIYWOIVXJVRKHZR34UMEHQBXS/" }, { "name": "FEDORA-2021-c52c0fe490", "tags": [ "vendor-advisory" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/6T2TURBYYJGBMQTTN2DSOAIQGP7WCPGV/" }, { "url": "https://security.netapp.com/advisory/ntap-20211223-0002/" }, { "url": "https://claroty.com/team82/research/unboxing-busybox-14-vulnerabilities-uncovered-by-claroty-jfrog" } ] } }, "cveMetadata": { "assignerOrgId": "48a46f29-ae42-4e1d-90dd-c1676c1e5e6d", "assignerShortName": "JFROG", "cveId": "CVE-2021-42383", "datePublished": "2021-11-15T00:00:00", "dateReserved": "2021-10-14T00:00:00", "dateUpdated": "2024-08-04T03:30:38.425Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-42383\",\"sourceIdentifier\":\"reefs@jfrog.com\",\"published\":\"2021-11-15T21:15:08.017\",\"lastModified\":\"2024-11-21T06:27:42.410\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function\"},{\"lang\":\"es\",\"value\":\"Un uso de memoria previamente liberada en el applet awk de Busybox conduce a la denegaci\u00f3n de servicio y posiblemente a una ejecuci\u00f3n de c\u00f3digo cuando es procesado un patr\u00f3n awk dise\u00f1ado en la funci\u00f3n evaluate\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"reefs@jfrog.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:busybox:busybox:1.33.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4E183752-159F-467F-9DCB-B7AED9DC2288\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fedoraproject:fedora:33:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E460AA51-FCDA-46B9-AE97-E6676AA5E194\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A930E247-0B43-43CB-98FF-6CE7B8189835\"}]}]}],\"references\":[{\"url\":\"https://claroty.com/team82/research/unboxing-busybox-14-vulnerabilities-uncovered-by-claroty-jfrog\",\"source\":\"reefs@jfrog.com\"},{\"url\":\"https://jfrog.com/blog/unboxing-busybox-14-new-vulnerabilities-uncovered-by-claroty-and-jfrog/\",\"source\":\"reefs@jfrog.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/6T2TURBYYJGBMQTTN2DSOAIQGP7WCPGV/\",\"source\":\"reefs@jfrog.com\"},{\"url\":\"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/UQXGOGWBIYWOIVXJVRKHZR34UMEHQBXS/\",\"source\":\"reefs@jfrog.com\"},{\"url\":\"https://security.netapp.com/advisory/ntap-20211223-0002/\",\"source\":\"reefs@jfrog.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://claroty.com/team82/research/unboxing-busybox-14-vulnerabilities-uncovered-by-claroty-jfrog\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://jfrog.com/blog/unboxing-busybox-14-new-vulnerabilities-uncovered-by-claroty-and-jfrog/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/6T2TURBYYJGBMQTTN2DSOAIQGP7WCPGV/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/UQXGOGWBIYWOIVXJVRKHZR34UMEHQBXS/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://security.netapp.com/advisory/ntap-20211223-0002/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
gsd-2021-42383
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A use-after-free in Busybox's awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function
Aliases
Aliases
{ "GSD": { "alias": "CVE-2021-42383", "description": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function", "id": "GSD-2021-42383", "references": [ "https://www.suse.com/security/cve/CVE-2021-42383.html", "https://advisories.mageia.org/CVE-2021-42383.html", "https://security.archlinux.org/CVE-2021-42383" ] }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-42383" ], "details": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function", "id": "GSD-2021-42383", "modified": "2023-12-13T01:23:06.134436Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "security@jfrog.com", "ID": "CVE-2021-42383", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "busybox", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "1.34.0" } ] } } ] }, "vendor_name": "busybox" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function" } ] }, "impact": { "cvssv3": { "SCORE": "6.6" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-416" } ] } ] }, "references": { "reference_data": [ { "name": "https://jfrog.com/blog/unboxing-busybox-14-new-vulnerabilities-uncovered-by-claroty-and-jfrog/", "refsource": "MISC", "url": "https://jfrog.com/blog/unboxing-busybox-14-new-vulnerabilities-uncovered-by-claroty-and-jfrog/" }, { "name": "FEDORA-2021-5a95823596", "refsource": "FEDORA", "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/UQXGOGWBIYWOIVXJVRKHZR34UMEHQBXS/" }, { "name": "FEDORA-2021-c52c0fe490", "refsource": "FEDORA", "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/6T2TURBYYJGBMQTTN2DSOAIQGP7WCPGV/" }, { "name": "https://security.netapp.com/advisory/ntap-20211223-0002/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20211223-0002/" }, { "name": "https://claroty.com/team82/research/unboxing-busybox-14-vulnerabilities-uncovered-by-claroty-jfrog", "refsource": "MISC", "url": "https://claroty.com/team82/research/unboxing-busybox-14-vulnerabilities-uncovered-by-claroty-jfrog" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:busybox:busybox:1.33.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fedoraproject:fedora:33:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "security@jfrog.com", "ID": "CVE-2021-42383" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-416" } ] } ] }, "references": { "reference_data": [ { "name": "N/A", "refsource": "N/A", "tags": [ "Third Party Advisory" ], "url": "https://jfrog.com/blog/unboxing-busybox-14-new-vulnerabilities-uncovered-by-claroty-and-jfrog/" }, { "name": "FEDORA-2021-c52c0fe490", "refsource": "FEDORA", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/6T2TURBYYJGBMQTTN2DSOAIQGP7WCPGV/" }, { "name": "FEDORA-2021-5a95823596", "refsource": "FEDORA", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/UQXGOGWBIYWOIVXJVRKHZR34UMEHQBXS/" }, { "name": "https://security.netapp.com/advisory/ntap-20211223-0002/", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20211223-0002/" }, { "name": "https://claroty.com/team82/research/unboxing-busybox-14-vulnerabilities-uncovered-by-claroty-jfrog", "refsource": "MISC", "tags": [], "url": "https://claroty.com/team82/research/unboxing-busybox-14-vulnerabilities-uncovered-by-claroty-jfrog" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9 } }, "lastModifiedDate": "2023-04-25T22:15Z", "publishedDate": "2021-11-15T21:15Z" } } }
ICSA-23-080-07
Vulnerability from csaf_cisa
Published
2023-03-29 16:37
Modified
2023-03-29 16:37
Summary
Siemens SCALANCE Third-Party
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or disclose sensitive data.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
No known public exploits specifically target these vulnerabilities. These vulnerabilities have a high attack complexity.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or disclose sensitive data. ", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities have a high attack complexity.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-565386: Third-Party Component Vulnerabilities in SCALANCE W-700 IEEE 802.11ax devices before V2.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-565386.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-080-07 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-080-07.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-080-07 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-07" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/Recommended-Practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "SSA-565386: Third-Party Component Vulnerabilities in SCALANCE W-700 IEEE 802.11ax devices before V2.0 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565386.pdf" }, { "category": "external", "summary": "SSA-565386: Third-Party Component Vulnerabilities in SCALANCE W-700 IEEE 802.11ax devices before V2.0 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-565386.txt" } ], "title": "Siemens SCALANCE Third-Party", "tracking": { "current_release_date": "2023-03-29T16:37:57.347759Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-080-07", "initial_release_date": "2023-03-29T16:37:57.347759Z", "revision_history": [ { "date": "2023-03-29T16:37:57.347759Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-7DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0)", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7TA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)", "product_id": "CSAFPID-0005", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7TB0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)", "product_id": "CSAFPID-0006", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)", "product_id": "CSAFPID-0007", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3AA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0)", "product_id": "CSAFPID-0008", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-3DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0)", "product_id": "CSAFPID-0009", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-3DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-12886", "cwe": { "id": "CWE-209", "name": "Generation of Error Message Containing Sensitive Information" }, "notes": [ { "category": "summary", "text": "stack_protect_prologue in cfgexpand.c and stack_protect_epilogue in function.c in GNU Compiler Collection (GCC) 4.1 through 8 (under certain circumstances) generate instruction sequences when targeting ARM targets that spill the address of the stack protector guard, which allows an attacker to bypass the protection of -fstack-protector, -fstack-protector-all, -fstack-protector-strong, and -fstack-protector-explicit against stack overflow by controlling what the stack canary is compared against.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-12886" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2018-12886" }, { "cve": "CVE-2018-25032", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-25032" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2018-25032" }, { "cve": "CVE-2021-42373", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s man applet leads to denial of service when a section name is supplied but no page argument is given.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42373" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42373" }, { "cve": "CVE-2021-42374", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42374" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42375", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An incorrect handling of a special element in Busybox\u0027s ash applet leads to denial of service when processing a crafted shell command, due to the shell mistaking specific characters for reserved characters. This may be used for DoS under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42375" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42376", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s hush applet leads to denial of service when processing a crafted shell command, due to missing validation after a \\x03 delimiter character. This may be used for DoS under very rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42376" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42377", "cwe": { "id": "CWE-763", "name": "Release of Invalid Pointer or Reference" }, "notes": [ { "category": "summary", "text": "An attacker-controlled pointer free in Busybox\u0027s hush applet leads to denial of service and possible code execution when processing a crafted shell command, due to the shell mishandling the \u0026\u0026\u0026 string. This may be used for remote code execution under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42377" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42378", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42378" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42379" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42380" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42381" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42382" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42383" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42384" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42385" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42386" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42386" }, { "cve": "CVE-2022-23395", "cwe": { "id": "CWE-1321", "name": "Improperly Controlled Modification of Object Prototype Attributes (\u0027Prototype Pollution\u0027)" }, "notes": [ { "category": "summary", "text": "jQuery Cookie 1.4.1 is affected by prototype pollution, which can lead to DOM cross-site scripting (XSS).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23395" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2022-23395" } ] }
icsa-23-166-10
Vulnerability from csaf_cisa
Published
2023-06-13 00:00
Modified
2023-06-13 00:00
Summary
Siemens SIMATIC S7-1500 TM MFP BIOS
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Summary
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP V1.0.
Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimizing network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices
Locating control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices
When remote access is required, using more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Exploitability
No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "summary", "text": "Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP V1.0.\n\nSiemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimizing network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locating control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, using more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "other", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP V1.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-831302.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-166-10 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-166-10.json" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP V1.0 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-831302.html" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP V1.0 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-831302.pdf" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP V1.0 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-831302.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-166-10 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-10" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SIMATIC S7-1500 TM MFP BIOS", "tracking": { "current_release_date": "2023-06-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-166-10", "initial_release_date": "2023-06-13T00:00:00.000000Z", "revision_history": [ { "date": "2023-06-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC S7-1500 TM MFP - BIOS", "product_id": "1" } } ], "category": "product_name", "name": "SIMATIC S7-1500 TM MFP - BIOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-10228", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The iconv program in the GNU C Library (aka glibc or libc6) 2.31 and earlier, when invoked with multiple suffixes in the destination encoding (TRANSLATE or IGNORE) along with the -c option, enters an infinite loop when processing invalid multi-byte input sequences, leading to a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2016-10228" }, { "cve": "CVE-2019-25013", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The iconv feature in the GNU C Library (aka glibc or libc6) through 2.32, when processing invalid multi-byte input sequences in the EUC-KR encoding, may have a buffer over-read.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2019-25013" }, { "cve": "CVE-2020-1752", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability introduced in glibc upstream version 2.14 was found in the way the tilde expansion was carried out. Directory paths containing an initial tilde followed by a valid username were affected by this issue. A local attacker could exploit this flaw by creating a specially crafted path that, when processed by the glob function, would potentially lead to arbitrary code execution. This was fixed in version 2.32.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-1752" }, { "cve": "CVE-2020-10029", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The GNU C Library (aka glibc or libc6) before 2.32 could overflow an on-stack buffer during range reduction if an input to an 80-bit long double function contains a non-canonical bit pattern, a seen when passing a 0x5d414141414141410000 value to sinl on x86 targets. This is related to sysdeps/ieee754/ldbl-96/e_rem_pio2l.c.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-10029" }, { "cve": "CVE-2020-27618", "cwe": { "id": "CWE-835", "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.32 and earlier, when processing invalid multi-byte input sequences in IBM1364, IBM1371, IBM1388, IBM1390, and IBM1399 encodings, fails to advance the input state, which could lead to an infinite loop in applications, resulting in a denial of service, a different vulnerability from CVE-2016-10228.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-27618" }, { "cve": "CVE-2020-29562", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.30 to 2.32, when converting UCS4 text containing an irreversible character, fails an assertion in the code path and aborts the program, potentially resulting in a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-29562" }, { "cve": "CVE-2021-3326", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.32 and earlier, when processing invalid input sequences in the ISO-2022-JP-3 encoding, fails an assertion in the code path and aborts the program, potentially resulting in a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3326" }, { "cve": "CVE-2021-3998", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. The realpath() function can mistakenly return an unexpected value, potentially leading to information leakage and disclosure of sensitive data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3998" }, { "cve": "CVE-2021-3999", "cwe": { "id": "CWE-193", "name": "Off-by-one Error" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. An off-by-one buffer overflow and underflow in getcwd() may lead to memory corruption when the size of the buffer is exactly 1. A local attacker who can control the input buffer and size passed to getcwd() in a setuid program could use this flaw to potentially execute arbitrary code and escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3999" }, { "cve": "CVE-2021-20269", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "A flaw was found in the permissions of a log file created by kexec-tools. This flaw allows a local unprivileged user to read this file and leak kernel internal information from a previous panic. The highest threat from this vulnerability is to confidentiality. This flaw affects kexec-tools shipped by Fedora versions prior to 2.0.21-8 and RHEL versions prior to 2.0.20-47.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-20269" }, { "cve": "CVE-2021-27645", "cwe": { "id": "CWE-415", "name": "Double Free" }, "notes": [ { "category": "summary", "text": "The nameserver caching daemon (nscd) in the GNU C Library (aka glibc or libc6) 2.29 through 2.33, when processing a request for netgroup lookup, may crash due to a double-free, potentially resulting in degraded service or Denial of Service on the local system. This is related to netgroupcache.c.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.5, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-27645" }, { "cve": "CVE-2021-28831", "cwe": { "id": "CWE-755", "name": "Improper Handling of Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "decompress_gunzip.c in BusyBox through 1.32.1 mishandles the error bit on the huft_build result pointer, with a resultant invalid free or segmentation fault, via malformed gzip data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-28831" }, { "cve": "CVE-2021-33574", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The mq_notify function in the GNU C Library (aka glibc) versions 2.32 and 2.33 has a use-after-free. It may use the notification thread attributes object (passed through its struct sigevent parameter) after it has been freed by the caller, leading to a denial of service (application crash) or possibly unspecified other impact.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-33574" }, { "cve": "CVE-2021-35942", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "The wordexp function in the GNU C Library (aka glibc) through 2.33 may crash or read arbitrary memory in parse_param (in posix/wordexp.c) when called with an untrusted, crafted pattern, potentially resulting in a denial of service or disclosure of information. This occurs because atoi was used but strtoul should have been used to ensure correct calculations.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-35942" }, { "cve": "CVE-2021-38604", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "In librt in the GNU C Library (aka glibc) through 2.34, sysdeps/unix/sysv/linux/mq_notify.c mishandles certain NOTIFY_REMOVED data, leading to a NULL pointer dereference. NOTE: this vulnerability was introduced as a side effect of the CVE-2021-33574 fix.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-38604" }, { "cve": "CVE-2021-42373", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s man applet leads to denial of service when a section name is supplied but no page argument is given.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42373" }, { "cve": "CVE-2021-42374", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42375", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An incorrect handling of a special element in Busybox\u0027s ash applet leads to denial of service when processing a crafted shell command, due to the shell mistaking specific characters for reserved characters. This may be used for DoS under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42376", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s hush applet leads to denial of service when processing a crafted shell command, due to missing validation after a \\x03 delimiter character. This may be used for DoS under very rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42377", "cwe": { "id": "CWE-763", "name": "Release of Invalid Pointer or Reference" }, "notes": [ { "category": "summary", "text": "An attacker-controlled pointer free in Busybox\u0027s hush applet leads to denial of service and possible code execution when processing a crafted shell command, due to the shell mishandling the \u0026\u0026\u0026 string. This may be used for remote code execution under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42378", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42386" }, { "cve": "CVE-2022-1882", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u2019s pipes functionality in how a user performs manipulations with the pipe post_one_notification() after free_pipe_info() that is already called. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-1882" }, { "cve": "CVE-2022-2585", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u2019s POSIX CPU timers functionality in the way a user creates and then deletes the timer in the non-leader thread of the program. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2585" }, { "cve": "CVE-2022-2588", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Zhenpeng Lin discovered that the network packet scheduler implementation in the Linux kernel did not properly remove all references to a route filter before freeing it in some situations. A local attacker could use this to cause a denial of service (system crash) or execute arbitrary code.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2588" }, { "cve": "CVE-2022-2905", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds memory read flaw was found in the Linux kernel\u0027s BPF subsystem in how a user calls the bpf_tail_call function with a key larger than the max_entries of the map. This flaw allows a local user to gain unauthorized access to data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2905" }, { "cve": "CVE-2022-3028", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "A race condition was found in the Linux kernel\u0027s IP framework for transforming packets (XFRM subsystem) when multiple calls to xfrm_probe_algs occurred simultaneously. This flaw could allow a local attacker to potentially trigger an out-of-bounds write or leak kernel heap memory by performing an out-of-bounds read and copying it into a socket.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3028" }, { "cve": "CVE-2022-3435", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "A vulnerability classified as problematic has been found in Linux Kernel. This affects the function fib_nh_match of the file net/ipv4/fib_semantics.c of the component IPv4 Handler. The manipulation leads to out-of-bounds read. It is possible to initiate the attack remotely. It is recommended to apply a patch to fix this issue. The identifier VDB-210357 was assigned to this vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3435" }, { "cve": "CVE-2022-3586", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel\u2019s networking code. A use-after-free was found in the way the sch_sfb enqueue function used the socket buffer (SKB) cb field after the same SKB had been enqueued (and freed) into a child qdisc. This flaw allows a local, unprivileged user to crash the system, causing a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3586" }, { "cve": "CVE-2022-4378", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A stack overflow flaw was found in the Linux kernel\u0027s SYSCTL subsystem in how a user changes certain kernel parameters and variables. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-4378" }, { "cve": "CVE-2022-4662", "cwe": { "id": "CWE-455", "name": "Non-exit on Failed Initialization" }, "notes": [ { "category": "summary", "text": "A flaw incorrect access control in the Linux kernel USB core subsystem was found in the way user attaches usb device. A local user could use this flaw to crash the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-4662" }, { "cve": "CVE-2022-20421", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "In binder_inc_ref_for_node of binder.c, there is a possible way to corrupt memory due to a use after free. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-239630375References: Upstream kernel", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-20421" }, { "cve": "CVE-2022-20422", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "In emulation_proc_handler of armv8_deprecated.c, there is a possible way to corrupt memory due to a race condition. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-237540956References: Upstream kernel", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-20422" }, { "cve": "CVE-2022-21233", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "Improper isolation of shared resources in some Intel(R) Processors may allow a privileged user to potentially enable information disclosure via local access.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-21233" }, { "cve": "CVE-2022-23218", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The deprecated compatibility function svcunix_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its path argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-23218" }, { "cve": "CVE-2022-23219", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The deprecated compatibility function clnt_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its hostname argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-23219" }, { "cve": "CVE-2022-28391", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "BusyBox through 1.35.0 allows remote attackers to execute arbitrary code if netstat is used to print a DNS PTR record\u0027s value to a VT compatible terminal. Alternatively, the attacker could choose to change the terminal\u0027s colors.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-28391" }, { "cve": "CVE-2022-30065", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox 1.35-x\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-30065" }, { "cve": "CVE-2022-39188", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "An issue was discovered in include/asm-generic/tlb.h in the Linux kernel before 5.19. Because of a race condition (unmap_mapping_range versus munmap), a device driver can free a page while it still has stale TLB entries. This only occurs in situations with VM_PFNMAP VMAs.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-39188" }, { "cve": "CVE-2022-39190", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "An issue was discovered in net/netfilter/nf_tables_api.c in the Linux kernel before 5.19.6. A denial of service can occur upon binding to an already bound chain.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-39190" }, { "cve": "CVE-2022-40307", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "An issue was discovered in the Linux kernel through 5.19.8. drivers/firmware/efi/capsule-loader.c has a race condition with a resultant use-after-free.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-40307" }, { "cve": "CVE-2022-41222", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "mm/mremap.c in the Linux kernel before 5.13.3 has a use-after-free via a stale TLB because an rmap lock is not held during a PUD move.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-41222" }, { "cve": "CVE-2022-42703", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "mm/rmap.c in the Linux kernel before 5.19.7 has a use-after-free related to leaf anon_vma double reuse.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-42703" }, { "cve": "CVE-2023-0179", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability was found in the Netfilter subsystem in the Linux Kernel. This issue could allow the leakage of both stack and heap addresses, and potentially allow Local Privilege Escalation to the root user via arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0179" }, { "cve": "CVE-2023-0394", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference flaw was found in rawv6_push_pending_frames in net/ipv6/raw.c in the network subcomponent in the Linux kernel. This flaw causes the system to crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0394" }, { "cve": "CVE-2023-1073", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A memory corruption flaw was found in the Linux kernel\u2019s human interface device (HID) subsystem in how a user inserts a malicious USB device. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-1073" } ] }
icsa-23-166-12
Vulnerability from csaf_cisa
Published
2023-06-13 00:00
Modified
2023-06-13 00:00
Summary
Siemens SINAMICS Medium Voltage Products
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Summary
Several SINAMICS MV (medium voltage) products are affected by multiple vulnerabilities in the integrated SCALANCE S615 device, as documented in SSA-419740 (
https://cert-portal.siemens.com/productcert/html/ssa-419740.html).
Siemens recommends to update the firmware of the integrated SCALANCE S615 device to the latest version. Siemens recommends specific countermeasures for products where the firmware update is not, or not yet applied.
Additional considerations regarding the specific impact of the vulnerabilities to SINAMICS MV products can be found in the chapter "Additional Information".
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimizing network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices
Locating control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices
When remote access is required, using more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Exploitability
No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "summary", "text": "Several SINAMICS MV (medium voltage) products are affected by multiple vulnerabilities in the integrated SCALANCE S615 device, as documented in SSA-419740 (\nhttps://cert-portal.siemens.com/productcert/html/ssa-419740.html).\nSiemens recommends to update the firmware of the integrated SCALANCE S615 device to the latest version. Siemens recommends specific countermeasures for products where the firmware update is not, or not yet applied.\n\nAdditional considerations regarding the specific impact of the vulnerabilities to SINAMICS MV products can be found in the chapter \"Additional Information\".", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimizing network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locating control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, using more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "\u200bNo known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "other", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-942865: Multiple Vulnerabilities in the Integrated SCALANCE S615 of SINAMICS Medium Voltage Products - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-942865.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-166-12 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-166-12.json" }, { "category": "self", "summary": "SSA-942865: Multiple Vulnerabilities in the Integrated SCALANCE S615 of SINAMICS Medium Voltage Products - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-942865.html" }, { "category": "self", "summary": "SSA-942865: Multiple Vulnerabilities in the Integrated SCALANCE S615 of SINAMICS Medium Voltage Products - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-942865.pdf" }, { "category": "self", "summary": "SSA-942865: Multiple Vulnerabilities in the Integrated SCALANCE S615 of SINAMICS Medium Voltage Products - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-942865.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-166-12 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-12" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SINAMICS Medium Voltage Products", "tracking": { "current_release_date": "2023-06-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-166-12", "initial_release_date": "2023-06-13T00:00:00.000000Z", "revision_history": [ { "date": "2023-06-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SINAMICS GL150", "product_id": "1" } } ], "category": "product_name", "name": "SINAMICS GL150" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SINAMICS PERFECT HARMONY GH180 6SR5", "product_id": "2" } } ], "category": "product_name", "name": "SINAMICS PERFECT HARMONY GH180 6SR5" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SINAMICS SL150", "product_id": "3" } } ], "category": "product_name", "name": "SINAMICS SL150" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-25032", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2018-25032" }, { "cve": "CVE-2021-42374", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42378", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42386" }, { "cve": "CVE-2022-0547", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "OpenVPN 2.1 until v2.4.12 and v2.5.6 may enable authentication bypass in external authentication plug-ins when more than one of them makes use of deferred authentication replies, which allows an external user to be granted access with only partially correct credentials.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-0547" }, { "cve": "CVE-2022-1199", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel. This flaw allows an attacker to crash the Linux kernel by simulating amateur radio from the user space, resulting in a null-ptr-deref vulnerability and a use-after-free vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-1199" }, { "cve": "CVE-2022-1292", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The c_rehash script does not properly sanitise shell metacharacters to prevent command injection.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-1292" }, { "cve": "CVE-2022-1343", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "Under certain circumstances, the command line OCSP verify function reports successful verification when the verification in fact failed. In this case the incorrect successful response will also be accompanied by error messages showing the failure and contradicting the apparently successful result.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-1343" }, { "cve": "CVE-2022-1473", "cwe": { "id": "CWE-404", "name": "Improper Resource Shutdown or Release" }, "notes": [ { "category": "summary", "text": "The used OpenSSL version improperly reuses memory when decoding certificates or keys. This can lead to a process termination and Denial of Service for long lived processes.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-1473" }, { "cve": "CVE-2022-23308", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "valid.c in libxml2 before 2.9.13 has a use-after-free of ID and IDREF attributes.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-23308" }, { "cve": "CVE-2022-32205", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "A malicious server can serve excessive amounts of \"Set-Cookie:\" headers in a HTTP response to curl and curl \u003c 7.84.0 stores all of them. A sufficiently large amount of (big) cookies make subsequent HTTP requests to this, or other servers to which the cookies match, create requests that become larger than the threshold that curl uses internally to avoid sending crazy large requests (1048576 bytes) and instead returns an error.This denial state might remain for as long as the same cookies are kept, match and haven\u0027t expired. Due to cookie matching rules, a server on \"foo.example.com\" can set cookies that also would match for \"bar.example.com\", making it it possible for a \"sister server\" to effectively cause a denial of service for a sibling site on the same second level domain using this method.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-32205" }, { "cve": "CVE-2022-32206", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "curl \u003c 7.84.0 supports \"chained\" HTTP compression algorithms, meaning that a serverresponse can be compressed multiple times and potentially with different algorithms. The number of acceptable \"links\" in this \"decompression chain\" was unbounded, allowing a malicious server to insert a virtually unlimited number of compression steps.The use of such a decompression chain could result in a \"malloc bomb\", makingcurl end up spending enormous amounts of allocated heap memory, or trying toand returning out of memory errors.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-32206" }, { "cve": "CVE-2022-32207", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "When curl \u003c 7.84.0 saves cookies, alt-svc and hsts data to local files, it makes the operation atomic by finalizing the operation with a rename from a temporary name to the final target file name.In that rename operation, it might accidentally *widen* the permissions for the target file, leaving the updated file accessible to more users than intended.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-32207" }, { "cve": "CVE-2022-32208", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "When curl \u003c 7.84.0 does FTP transfers secured by krb5, it handles message verification failures wrongly. This flaw makes it possible for a Man-In-The-Middle attack to go unnoticed and even allows it to inject data to the client.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-32208" }, { "cve": "CVE-2022-35252", "cwe": { "id": "CWE-1286", "name": "Improper Validation of Syntactic Correctness of Input" }, "notes": [ { "category": "summary", "text": "When curl is used to retrieve and parse cookies from a HTTP(S) server, itaccepts cookies using control codes that when later are sent back to a HTTPserver might make the server return 400 responses. Effectively allowing a\"sister site\" to deny service to all siblings.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-35252" }, { "cve": "CVE-2022-36946", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "nfqnl_mangle in net/netfilter/nfnetlink_queue.c in the Linux kernel through 5.18.14 allows remote attackers to cause a denial of service (panic) because, in the case of an nf_queue verdict with a one-byte nfta_payload attribute, an skb_pull can encounter a negative skb-\u003elen.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-36946" } ] }
ICSA-23-166-10
Vulnerability from csaf_cisa
Published
2023-06-13 00:00
Modified
2023-06-13 00:00
Summary
Siemens SIMATIC S7-1500 TM MFP BIOS
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Summary
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP V1.0.
Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimizing network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices
Locating control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices
When remote access is required, using more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Exploitability
No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "summary", "text": "Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP V1.0.\n\nSiemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimizing network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locating control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, using more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "other", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP V1.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-831302.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-166-10 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-166-10.json" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP V1.0 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-831302.html" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP V1.0 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-831302.pdf" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP V1.0 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-831302.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-166-10 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-10" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SIMATIC S7-1500 TM MFP BIOS", "tracking": { "current_release_date": "2023-06-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-166-10", "initial_release_date": "2023-06-13T00:00:00.000000Z", "revision_history": [ { "date": "2023-06-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC S7-1500 TM MFP - BIOS", "product_id": "1" } } ], "category": "product_name", "name": "SIMATIC S7-1500 TM MFP - BIOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-10228", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The iconv program in the GNU C Library (aka glibc or libc6) 2.31 and earlier, when invoked with multiple suffixes in the destination encoding (TRANSLATE or IGNORE) along with the -c option, enters an infinite loop when processing invalid multi-byte input sequences, leading to a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2016-10228" }, { "cve": "CVE-2019-25013", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The iconv feature in the GNU C Library (aka glibc or libc6) through 2.32, when processing invalid multi-byte input sequences in the EUC-KR encoding, may have a buffer over-read.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2019-25013" }, { "cve": "CVE-2020-1752", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability introduced in glibc upstream version 2.14 was found in the way the tilde expansion was carried out. Directory paths containing an initial tilde followed by a valid username were affected by this issue. A local attacker could exploit this flaw by creating a specially crafted path that, when processed by the glob function, would potentially lead to arbitrary code execution. This was fixed in version 2.32.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-1752" }, { "cve": "CVE-2020-10029", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The GNU C Library (aka glibc or libc6) before 2.32 could overflow an on-stack buffer during range reduction if an input to an 80-bit long double function contains a non-canonical bit pattern, a seen when passing a 0x5d414141414141410000 value to sinl on x86 targets. This is related to sysdeps/ieee754/ldbl-96/e_rem_pio2l.c.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-10029" }, { "cve": "CVE-2020-27618", "cwe": { "id": "CWE-835", "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.32 and earlier, when processing invalid multi-byte input sequences in IBM1364, IBM1371, IBM1388, IBM1390, and IBM1399 encodings, fails to advance the input state, which could lead to an infinite loop in applications, resulting in a denial of service, a different vulnerability from CVE-2016-10228.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-27618" }, { "cve": "CVE-2020-29562", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.30 to 2.32, when converting UCS4 text containing an irreversible character, fails an assertion in the code path and aborts the program, potentially resulting in a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-29562" }, { "cve": "CVE-2021-3326", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.32 and earlier, when processing invalid input sequences in the ISO-2022-JP-3 encoding, fails an assertion in the code path and aborts the program, potentially resulting in a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3326" }, { "cve": "CVE-2021-3998", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. The realpath() function can mistakenly return an unexpected value, potentially leading to information leakage and disclosure of sensitive data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3998" }, { "cve": "CVE-2021-3999", "cwe": { "id": "CWE-193", "name": "Off-by-one Error" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. An off-by-one buffer overflow and underflow in getcwd() may lead to memory corruption when the size of the buffer is exactly 1. A local attacker who can control the input buffer and size passed to getcwd() in a setuid program could use this flaw to potentially execute arbitrary code and escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3999" }, { "cve": "CVE-2021-20269", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "A flaw was found in the permissions of a log file created by kexec-tools. This flaw allows a local unprivileged user to read this file and leak kernel internal information from a previous panic. The highest threat from this vulnerability is to confidentiality. This flaw affects kexec-tools shipped by Fedora versions prior to 2.0.21-8 and RHEL versions prior to 2.0.20-47.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-20269" }, { "cve": "CVE-2021-27645", "cwe": { "id": "CWE-415", "name": "Double Free" }, "notes": [ { "category": "summary", "text": "The nameserver caching daemon (nscd) in the GNU C Library (aka glibc or libc6) 2.29 through 2.33, when processing a request for netgroup lookup, may crash due to a double-free, potentially resulting in degraded service or Denial of Service on the local system. This is related to netgroupcache.c.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.5, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-27645" }, { "cve": "CVE-2021-28831", "cwe": { "id": "CWE-755", "name": "Improper Handling of Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "decompress_gunzip.c in BusyBox through 1.32.1 mishandles the error bit on the huft_build result pointer, with a resultant invalid free or segmentation fault, via malformed gzip data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-28831" }, { "cve": "CVE-2021-33574", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The mq_notify function in the GNU C Library (aka glibc) versions 2.32 and 2.33 has a use-after-free. It may use the notification thread attributes object (passed through its struct sigevent parameter) after it has been freed by the caller, leading to a denial of service (application crash) or possibly unspecified other impact.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-33574" }, { "cve": "CVE-2021-35942", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "The wordexp function in the GNU C Library (aka glibc) through 2.33 may crash or read arbitrary memory in parse_param (in posix/wordexp.c) when called with an untrusted, crafted pattern, potentially resulting in a denial of service or disclosure of information. This occurs because atoi was used but strtoul should have been used to ensure correct calculations.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-35942" }, { "cve": "CVE-2021-38604", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "In librt in the GNU C Library (aka glibc) through 2.34, sysdeps/unix/sysv/linux/mq_notify.c mishandles certain NOTIFY_REMOVED data, leading to a NULL pointer dereference. NOTE: this vulnerability was introduced as a side effect of the CVE-2021-33574 fix.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-38604" }, { "cve": "CVE-2021-42373", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s man applet leads to denial of service when a section name is supplied but no page argument is given.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42373" }, { "cve": "CVE-2021-42374", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42375", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An incorrect handling of a special element in Busybox\u0027s ash applet leads to denial of service when processing a crafted shell command, due to the shell mistaking specific characters for reserved characters. This may be used for DoS under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42376", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s hush applet leads to denial of service when processing a crafted shell command, due to missing validation after a \\x03 delimiter character. This may be used for DoS under very rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42377", "cwe": { "id": "CWE-763", "name": "Release of Invalid Pointer or Reference" }, "notes": [ { "category": "summary", "text": "An attacker-controlled pointer free in Busybox\u0027s hush applet leads to denial of service and possible code execution when processing a crafted shell command, due to the shell mishandling the \u0026\u0026\u0026 string. This may be used for remote code execution under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42378", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42386" }, { "cve": "CVE-2022-1882", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u2019s pipes functionality in how a user performs manipulations with the pipe post_one_notification() after free_pipe_info() that is already called. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-1882" }, { "cve": "CVE-2022-2585", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u2019s POSIX CPU timers functionality in the way a user creates and then deletes the timer in the non-leader thread of the program. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2585" }, { "cve": "CVE-2022-2588", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Zhenpeng Lin discovered that the network packet scheduler implementation in the Linux kernel did not properly remove all references to a route filter before freeing it in some situations. A local attacker could use this to cause a denial of service (system crash) or execute arbitrary code.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2588" }, { "cve": "CVE-2022-2905", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds memory read flaw was found in the Linux kernel\u0027s BPF subsystem in how a user calls the bpf_tail_call function with a key larger than the max_entries of the map. This flaw allows a local user to gain unauthorized access to data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2905" }, { "cve": "CVE-2022-3028", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "A race condition was found in the Linux kernel\u0027s IP framework for transforming packets (XFRM subsystem) when multiple calls to xfrm_probe_algs occurred simultaneously. This flaw could allow a local attacker to potentially trigger an out-of-bounds write or leak kernel heap memory by performing an out-of-bounds read and copying it into a socket.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3028" }, { "cve": "CVE-2022-3435", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "A vulnerability classified as problematic has been found in Linux Kernel. This affects the function fib_nh_match of the file net/ipv4/fib_semantics.c of the component IPv4 Handler. The manipulation leads to out-of-bounds read. It is possible to initiate the attack remotely. It is recommended to apply a patch to fix this issue. The identifier VDB-210357 was assigned to this vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3435" }, { "cve": "CVE-2022-3586", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel\u2019s networking code. A use-after-free was found in the way the sch_sfb enqueue function used the socket buffer (SKB) cb field after the same SKB had been enqueued (and freed) into a child qdisc. This flaw allows a local, unprivileged user to crash the system, causing a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3586" }, { "cve": "CVE-2022-4378", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A stack overflow flaw was found in the Linux kernel\u0027s SYSCTL subsystem in how a user changes certain kernel parameters and variables. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-4378" }, { "cve": "CVE-2022-4662", "cwe": { "id": "CWE-455", "name": "Non-exit on Failed Initialization" }, "notes": [ { "category": "summary", "text": "A flaw incorrect access control in the Linux kernel USB core subsystem was found in the way user attaches usb device. A local user could use this flaw to crash the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-4662" }, { "cve": "CVE-2022-20421", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "In binder_inc_ref_for_node of binder.c, there is a possible way to corrupt memory due to a use after free. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-239630375References: Upstream kernel", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-20421" }, { "cve": "CVE-2022-20422", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "In emulation_proc_handler of armv8_deprecated.c, there is a possible way to corrupt memory due to a race condition. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-237540956References: Upstream kernel", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-20422" }, { "cve": "CVE-2022-21233", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "Improper isolation of shared resources in some Intel(R) Processors may allow a privileged user to potentially enable information disclosure via local access.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-21233" }, { "cve": "CVE-2022-23218", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The deprecated compatibility function svcunix_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its path argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-23218" }, { "cve": "CVE-2022-23219", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The deprecated compatibility function clnt_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its hostname argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-23219" }, { "cve": "CVE-2022-28391", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "BusyBox through 1.35.0 allows remote attackers to execute arbitrary code if netstat is used to print a DNS PTR record\u0027s value to a VT compatible terminal. Alternatively, the attacker could choose to change the terminal\u0027s colors.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-28391" }, { "cve": "CVE-2022-30065", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox 1.35-x\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-30065" }, { "cve": "CVE-2022-39188", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "An issue was discovered in include/asm-generic/tlb.h in the Linux kernel before 5.19. Because of a race condition (unmap_mapping_range versus munmap), a device driver can free a page while it still has stale TLB entries. This only occurs in situations with VM_PFNMAP VMAs.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-39188" }, { "cve": "CVE-2022-39190", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "An issue was discovered in net/netfilter/nf_tables_api.c in the Linux kernel before 5.19.6. A denial of service can occur upon binding to an already bound chain.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-39190" }, { "cve": "CVE-2022-40307", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "An issue was discovered in the Linux kernel through 5.19.8. drivers/firmware/efi/capsule-loader.c has a race condition with a resultant use-after-free.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-40307" }, { "cve": "CVE-2022-41222", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "mm/mremap.c in the Linux kernel before 5.13.3 has a use-after-free via a stale TLB because an rmap lock is not held during a PUD move.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-41222" }, { "cve": "CVE-2022-42703", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "mm/rmap.c in the Linux kernel before 5.19.7 has a use-after-free related to leaf anon_vma double reuse.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-42703" }, { "cve": "CVE-2023-0179", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability was found in the Netfilter subsystem in the Linux Kernel. This issue could allow the leakage of both stack and heap addresses, and potentially allow Local Privilege Escalation to the root user via arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0179" }, { "cve": "CVE-2023-0394", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference flaw was found in rawv6_push_pending_frames in net/ipv6/raw.c in the network subcomponent in the Linux kernel. This flaw causes the system to crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0394" }, { "cve": "CVE-2023-1073", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A memory corruption flaw was found in the Linux kernel\u2019s human interface device (HID) subsystem in how a user inserts a malicious USB device. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1" ] }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-1073" } ] }
icsa-23-080-07
Vulnerability from csaf_cisa
Published
2023-03-29 16:37
Modified
2023-03-29 16:37
Summary
Siemens SCALANCE Third-Party
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or disclose sensitive data.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
No known public exploits specifically target these vulnerabilities. These vulnerabilities have a high attack complexity.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or disclose sensitive data. ", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities have a high attack complexity.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-565386: Third-Party Component Vulnerabilities in SCALANCE W-700 IEEE 802.11ax devices before V2.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-565386.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-080-07 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-080-07.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-080-07 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-07" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/Recommended-Practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "SSA-565386: Third-Party Component Vulnerabilities in SCALANCE W-700 IEEE 802.11ax devices before V2.0 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565386.pdf" }, { "category": "external", "summary": "SSA-565386: Third-Party Component Vulnerabilities in SCALANCE W-700 IEEE 802.11ax devices before V2.0 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-565386.txt" } ], "title": "Siemens SCALANCE Third-Party", "tracking": { "current_release_date": "2023-03-29T16:37:57.347759Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-080-07", "initial_release_date": "2023-03-29T16:37:57.347759Z", "revision_history": [ { "date": "2023-03-29T16:37:57.347759Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-7DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0)", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7TA0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)", "product_id": "CSAFPID-0005", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-7TB0" ] } } } ], "category": "product_name", "name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)", "product_id": "CSAFPID-0006", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)", "product_id": "CSAFPID-0007", "product_identification_helper": { "model_numbers": [ "6GK5763-1AL00-3AA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0)", "product_id": "CSAFPID-0008", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-3DA0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V2.0", "product": { "name": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0)", "product_id": "CSAFPID-0009", "product_identification_helper": { "model_numbers": [ "6GK5766-1GE00-3DB0" ] } } } ], "category": "product_name", "name": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-12886", "cwe": { "id": "CWE-209", "name": "Generation of Error Message Containing Sensitive Information" }, "notes": [ { "category": "summary", "text": "stack_protect_prologue in cfgexpand.c and stack_protect_epilogue in function.c in GNU Compiler Collection (GCC) 4.1 through 8 (under certain circumstances) generate instruction sequences when targeting ARM targets that spill the address of the stack protector guard, which allows an attacker to bypass the protection of -fstack-protector, -fstack-protector-all, -fstack-protector-strong, and -fstack-protector-explicit against stack overflow by controlling what the stack canary is compared against.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-12886" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2018-12886" }, { "cve": "CVE-2018-25032", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-25032" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2018-25032" }, { "cve": "CVE-2021-42373", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s man applet leads to denial of service when a section name is supplied but no page argument is given.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42373" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42373" }, { "cve": "CVE-2021-42374", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42374" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42375", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An incorrect handling of a special element in Busybox\u0027s ash applet leads to denial of service when processing a crafted shell command, due to the shell mistaking specific characters for reserved characters. This may be used for DoS under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42375" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42376", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s hush applet leads to denial of service when processing a crafted shell command, due to missing validation after a \\x03 delimiter character. This may be used for DoS under very rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42376" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42377", "cwe": { "id": "CWE-763", "name": "Release of Invalid Pointer or Reference" }, "notes": [ { "category": "summary", "text": "An attacker-controlled pointer free in Busybox\u0027s hush applet leads to denial of service and possible code execution when processing a crafted shell command, due to the shell mishandling the \u0026\u0026\u0026 string. This may be used for remote code execution under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42377" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42378", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42378" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42379" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42380" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42381" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42382" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42383" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42384" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42385" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42386" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2021-42386" }, { "cve": "CVE-2022-23395", "cwe": { "id": "CWE-1321", "name": "Improperly Controlled Modification of Object Prototype Attributes (\u0027Prototype Pollution\u0027)" }, "notes": [ { "category": "summary", "text": "jQuery Cookie 1.4.1 is affected by prototype pollution, which can lead to DOM cross-site scripting (XSS).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23395" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0009" ] } ], "title": "CVE-2022-23395" } ] }
icsa-23-075-01
Vulnerability from csaf_cisa
Published
2023-03-31 17:50
Modified
2023-03-31 17:50
Summary
Siemens SCALANCE, RUGGEDCOM Third-Party
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to inject code or cause a denial-of-service condition.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Recommended Practices
Do not click web links or open attachments in unsolicited email messages.
Recommended Practices
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Recommended Practices
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
Recommended Practices
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to inject code or cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Do not click web links or open attachments in unsolicited email messages.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-419740: Multiple\tThird-Party Component Vulnerabilities in RUGGEDCOM and SCALANCE Products before V7.2 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-419740.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-075-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-075-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-075-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-075-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/Recommended-Practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "SSA-419740: Multiple\tThird-Party Component Vulnerabilities in RUGGEDCOM and SCALANCE Products before V7.2 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-419740.pdf" }, { "category": "external", "summary": "SSA-419740: Multiple\tThird-Party Component Vulnerabilities in RUGGEDCOM and SCALANCE Products before V7.2 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-419740.txt" } ], "title": "Siemens SCALANCE, RUGGEDCOM Third-Party", "tracking": { "current_release_date": "2023-03-31T17:50:48.679470Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-075-01", "initial_release_date": "2023-03-31T17:50:48.679470Z", "revision_history": [ { "date": "2023-03-31T17:50:48.679470Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2BA2" ] } } } ], "category": "product_name", "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2DA2" ] } } } ], "category": "product_name", "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5804-0AP00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK5812-1AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)", "product_id": "CSAFPID-0005", "product_identification_helper": { "model_numbers": [ "6GK5812-1BA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)", "product_id": "CSAFPID-0006", "product_identification_helper": { "model_numbers": [ "6GK5816-1AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)", "product_id": "CSAFPID-0007", "product_identification_helper": { "model_numbers": [ "6GK5816-1BA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)", "product_id": "CSAFPID-0008", "product_identification_helper": { "model_numbers": [ "6GK5826-2AB00-2AB2" ] } } } ], "category": "product_name", "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)", "product_id": "CSAFPID-0009", "product_identification_helper": { "model_numbers": [ "6GK5874-2AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)", "product_id": "CSAFPID-00010", "product_identification_helper": { "model_numbers": [ "6GK5874-3AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)", "product_id": "CSAFPID-00011", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)", "product_id": "CSAFPID-00012", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2EA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)", "product_id": "CSAFPID-00013", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA10-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)", "product_id": "CSAFPID-00014", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)", "product_id": "CSAFPID-00015", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2DA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)", "product_id": "CSAFPID-00016", "product_identification_helper": { "model_numbers": [ "6GK5853-2EA00-2DA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)", "product_id": "CSAFPID-00017", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3DA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)", "product_id": "CSAFPID-00018", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3AA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE S615 (6GK5615-0AA00-2AA2)", "product_id": "CSAFPID-00019", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE S615 (6GK5615-0AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE S615 EEC (6GK5615-0AA01-2AA2)", "product_id": "CSAFPID-00020", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA01-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE S615 EEC (6GK5615-0AA01-2AA2)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-25032", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-25032" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2018-25032" }, { "cve": "CVE-2019-1125", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "An information disclosure vulnerability exists when certain central processing units (CPU) speculatively access memory, aka \u0027Windows Kernel Information Disclosure Vulnerability\u0027. This CVE ID is unique from CVE-2019-1071, CVE-2019-1073.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-1125" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2019-1125" }, { "cve": "CVE-2021-4034", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A local privilege escalation vulnerability was found on polkit\u0027s pkexec utility. The pkexec application is a setuid tool designed to allow unprivileged users to run commands as privileged users according predefined policies. The current version of pkexec doesn\u0027t handle the calling parameters count correctly and ends trying to execute environment variables as commands. An attacker can leverage this by crafting environment variables in such a way it\u0027ll induce pkexec to execute arbitrary code. When successfully executed the attack can cause a local privilege escalation given unprivileged users administrative rights on the target machine.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-4034" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-4034" }, { "cve": "CVE-2021-4149", "cwe": { "id": "CWE-667", "name": "Improper Locking" }, "notes": [ { "category": "summary", "text": "A vulnerability was found in btrfs_alloc_tree_b in fs/btrfs/extent-tree.c in the Linux kernel due to an improper lock operation in btrfs. In this flaw, a user with a local privilege may cause a denial of service (DOS) due to a deadlock problem.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-4149" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-4149" }, { "cve": "CVE-2021-26401", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "LFENCE/JMP (mitigation V2-2) may not sufficiently mitigate CVE-2017-5715 on some AMD CPUs.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-26401" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-26401" }, { "cve": "CVE-2021-42373", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s man applet leads to denial of service when a section name is supplied but no page argument is given.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42373" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42373" }, { "cve": "CVE-2021-42374", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42374" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42375", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An incorrect handling of a special element in Busybox\u0027s ash applet leads to denial of service when processing a crafted shell command, due to the shell mistaking specific characters for reserved characters. This may be used for DoS under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42375" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42376", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s hush applet leads to denial of service when processing a crafted shell command, due to missing validation after a \\x03 delimiter character. This may be used for DoS under very rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42376" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42377", "cwe": { "id": "CWE-763", "name": "Release of Invalid Pointer or Reference" }, "notes": [ { "category": "summary", "text": "An attacker-controlled pointer free in Busybox\u0027s hush applet leads to denial of service and possible code execution when processing a crafted shell command, due to the shell mishandling the \u0026\u0026\u0026 string. This may be used for remote code execution under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42377" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42378", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42378" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42379" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42380" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42381" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42382" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42383" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42384" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42385" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42386" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42386" }, { "cve": "CVE-2022-0001", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Non-transparent sharing of branch predictor selectors between contexts in some Intel(R) Processors may allow an authorized user to potentially enable information disclosure via local access.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-0001" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-0001" }, { "cve": "CVE-2022-0002", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Non-transparent sharing of branch predictor within a context in some Intel(R) Processors may allow an authorized user to potentially enable information disclosure via local access.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-0002" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-0002" }, { "cve": "CVE-2022-0494", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "A kernel information leak flaw was identified in the scsi_ioctl function in drivers/scsi/scsi_ioctl.c in the Linux kernel. This flaw allows a local attacker with a special user privilege (CAP_SYS_ADMIN or CAP_SYS_RAWIO) to create issues with confidentiality.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-0494" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-0494" }, { "cve": "CVE-2022-0547", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "OpenVPN 2.1 until v2.4.12 and v2.5.6 may enable authentication bypass in external authentication plug-ins when more than one of them makes use of deferred authentication replies, which allows an external user to be granted access with only partially correct credentials.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-0547" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-0547" }, { "cve": "CVE-2022-1011", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u2019s FUSE filesystem in the way a user triggers write(). This flaw allows a local user to gain unauthorized access to data from the FUSE filesystem, resulting in privilege escalation.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1011" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1011" }, { "cve": "CVE-2022-1016", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel in net/netfilter/nf_tables_core.c:nft_do_chain, which can cause a use-after-free. This issue needs to handle \u0027return\u0027 with proper preconditions, as it can lead to a kernel information leak problem caused by a local, unprivileged attacker.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1016" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1016" }, { "cve": "CVE-2022-1198", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerabilitity was discovered in drivers/net/hamradio/6pack.c of linux that allows an attacker to crash linux kernel by simulating ax25 device using 6pack driver from user space.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1198" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1198" }, { "cve": "CVE-2022-1199", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel. This flaw allows an attacker to crash the Linux kernel by simulating amateur radio from the user space, resulting in a null-ptr-deref vulnerability and a use-after-free vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1199" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1199" }, { "cve": "CVE-2022-1292", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The c_rehash script does not properly sanitise shell metacharacters to prevent command injection.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1292" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1292" }, { "cve": "CVE-2022-1304", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read/write vulnerability was found in e2fsprogs 1.46.5. This issue leads to a segmentation fault and possibly arbitrary code execution via a specially crafted filesystem.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1304" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1304" }, { "cve": "CVE-2022-1343", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "Under certain circumstances, the command line OCSP verify function reports successful verification when the varification in fact failed. In this case the incorrect successful response will also be accompanied by error messages showing the failure and contradicting the apparently successful result.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1343" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1343" }, { "cve": "CVE-2022-1353", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "A vulnerability was found in the pfkey_register function in net/key/af_key.c in the Linux kernel. This flaw allows a local, unprivileged user to gain access to kernel memory, leading to a system crash or a leak of internal kernel information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1353" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1353" }, { "cve": "CVE-2022-1473", "cwe": { "id": "CWE-404", "name": "Improper Resource Shutdown or Release" }, "notes": [ { "category": "summary", "text": "The used OpenSSL version improperly reuses memory when decoding certificates or keys. This can lead to a process termination and Denial of Service for long lived processes.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1473" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1473" }, { "cve": "CVE-2022-1516", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference flaw was found in the Linux kernel\u2019s X.25 set of standardized network protocols functionality in the way a user terminates their session using a simulated Ethernet card and continued usage of this connection. This flaw allows a local user to crash the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1516" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1516" }, { "cve": "CVE-2022-1652", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Linux Kernel could allow a local attacker to execute arbitrary code on the system, caused by a concurrency use-after-free flaw in the bad_flp_intr function. By executing a specially-crafted program, an attacker could exploit this vulnerability to execute arbitrary code or cause a denial of service condition on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1652" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1652" }, { "cve": "CVE-2022-1729", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "A race condition was found the Linux kernel in perf_event_open() which can be exploited by an unprivileged user to gain root privileges. The bug allows to build several exploit primitives such as kernel address information leak, arbitrary execution, etc.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1729" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1729" }, { "cve": "CVE-2022-1734", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw in Linux Kernel found in nfcmrvl_nci_unregister_dev() in drivers/nfc/nfcmrvl/main.c can lead to use after free both read or write when non synchronized between cleanup routine and firmware download routine.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1734" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1734" }, { "cve": "CVE-2022-1974", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u0027s NFC core functionality due to a race condition between kobject creation and delete. This vulnerability allows a local attacker with CAP_NET_ADMIN privilege to leak kernel information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1974" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1974" }, { "cve": "CVE-2022-1975", "cwe": { "id": "CWE-248", "name": "Uncaught Exception" }, "notes": [ { "category": "summary", "text": "There is a sleep-in-atomic bug in /net/nfc/netlink.c that allows an attacker to crash the Linux kernel by simulating a nfc device from user-space.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1975" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1975" }, { "cve": "CVE-2022-2380", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Linux kernel was found vulnerable out of bounds memory access in the drivers/video/fbdev/sm712fb.c:smtcfb_read() function. The vulnerability could result in local attackers being able to crash the kernel.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2380" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-2380" }, { "cve": "CVE-2022-2588", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Zhenpeng Lin discovered that the network packet scheduler implementation in the Linux kernel did not properly remove all references to a route filter before freeing it in some situations. A local attacker could use this to cause a denial of service (system crash) or execute arbitrary code.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2588" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-2588" }, { "cve": "CVE-2022-2639", "cwe": { "id": "CWE-191", "name": "Integer Underflow (Wrap or Wraparound)" }, "notes": [ { "category": "summary", "text": "An integer coercion error was found in the openvswitch kernel module. Given a sufficiently large number of actions, while copying and reserving memory for a new action of a new flow, the reserve_sfa_size() function does not return -EMSGSIZE as expected, potentially leading to an out-of-bounds write access. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2639" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-2639" }, { "cve": "CVE-2022-20158", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "In bdi_put and bdi_unregister of backing-dev.c, there is a possible memory corruption due to a use after free. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-182815710References: Upstream kernel", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-20158" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-20158" }, { "cve": "CVE-2022-23036", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23036" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23036" }, { "cve": "CVE-2022-23037", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23037" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23037" }, { "cve": "CVE-2022-23038", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23038" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23038" }, { "cve": "CVE-2022-23039", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23039" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23039" }, { "cve": "CVE-2022-23040", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23040" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23040" }, { "cve": "CVE-2022-23041", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23041" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23041" }, { "cve": "CVE-2022-23042", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23042" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23042" }, { "cve": "CVE-2022-23308", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "valid.c in libxml2 before 2.9.13 has a use-after-free of ID and IDREF attributes.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23308" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23308" }, { "cve": "CVE-2022-26490", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "st21nfca_connectivity_event_received in drivers/nfc/st21nfca/se.c in the Linux kernel through 5.16.12 has EVT_TRANSACTION buffer overflows because of untrusted length parameters.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-26490" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-26490" }, { "cve": "CVE-2022-28356", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "In the Linux kernel before 5.17.1, a refcount leak bug was found in net/llc/af_llc.c.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-28356" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-28356" }, { "cve": "CVE-2022-28390", "cwe": { "id": "CWE-415", "name": "Double Free" }, "notes": [ { "category": "summary", "text": "ems_usb_start_xmit in drivers/net/can/usb/ems_usb.c in the Linux kernel through 5.17.1 has a double free.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-28390" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-28390" }, { "cve": "CVE-2022-30065", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox 1.35-x\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-30065" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-30065" }, { "cve": "CVE-2022-30594", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "summary", "text": "The Linux kernel before 5.17.2 mishandles seccomp permissions. The PTRACE_SEIZE code path allows attackers to bypass intended restrictions on setting the PT_SUSPEND_SECCOMP flag.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-30594" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-30594" }, { "cve": "CVE-2022-32205", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "A malicious server can serve excessive amounts of \"Set-Cookie:\" headers in a HTTP response to curl and curl \u003c 7.84.0 stores all of them. A sufficiently large amount of (big) cookies make subsequent HTTP requests to this, or other servers to which the cookies match, create requests that become larger than the threshold that curl uses internally to avoid sending crazy large requests (1048576 bytes) and instead returns an error.This denial state might remain for as long as the same cookies are kept, match and haven\u0027t expired. Due to cookie matching rules, a server on \"foo.example.com\" can set cookies that also would match for \"bar.example.com\", making it it possible for a \"sister server\" to effectively cause a denial of service for a sibling site on the same second level domain using this method.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32205" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32205" }, { "cve": "CVE-2022-32206", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "curl \u003c 7.84.0 supports \"chained\" HTTP compression algorithms, meaning that a serverresponse can be compressed multiple times and potentially with different algorithms. The number of acceptable \"links\" in this \"decompression chain\" was unbounded, allowing a malicious server to insert a virtually unlimited number of compression steps.The use of such a decompression chain could result in a \"malloc bomb\", makingcurl end up spending enormous amounts of allocated heap memory, or trying toand returning out of memory errors.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32206" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32206" }, { "cve": "CVE-2022-32207", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "When curl \u003c 7.84.0 saves cookies, alt-svc and hsts data to local files, it makes the operation atomic by finalizing the operation with a rename from a temporary name to the final target file name.In that rename operation, it might accidentally *widen* the permissions for the target file, leaving the updated file accessible to more users than intended.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32207" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32207" }, { "cve": "CVE-2022-32208", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "When curl \u003c 7.84.0 does FTP transfers secured by krb5, it handles message verification failures wrongly. This flaw makes it possible for a Man-In-The-Middle attack to go unnoticed and even allows it to inject data to the client.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32208" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32208" }, { "cve": "CVE-2022-32296", "cwe": { "id": "CWE-203", "name": "Observable Discrepancy" }, "notes": [ { "category": "summary", "text": "The Linux kernel before 5.17.9 allows TCP servers to identify clients by observing what source ports are used. This occurs because of use of Algorithm 4 (\"Double-Hash Port Selection Algorithm\") of RFC 6056.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32296" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32296" }, { "cve": "CVE-2022-32981", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "An issue was discovered in the Linux kernel through 5.18.3 on powerpc 32-bit platforms. There is a buffer overflow in ptrace PEEKUSER and POKEUSER (aka PEEKUSR and POKEUSR) when accessing floating point registers.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32981" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32981" }, { "cve": "CVE-2022-33981", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "drivers/block/floppy.c in the Linux kernel before 5.17.6 is vulnerable to a denial of service, because of a concurrency use-after-free flaw after deallocating raw_cmd in the raw_cmd_ioctl function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-33981" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-33981" }, { "cve": "CVE-2022-35252", "cwe": { "id": "CWE-1286", "name": "Improper Validation of Syntactic Correctness of Input" }, "notes": [ { "category": "summary", "text": "When curl is used to retrieve and parse cookies from a HTTP(S) server, itaccepts cookies using control codes that when later are sent back to a HTTPserver might make the server return 400 responses. Effectively allowing a\"sister site\" to deny service to all siblings.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-35252" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-35252" }, { "cve": "CVE-2022-36879", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An issue was discovered in the Linux kernel through 5.18.14. xfrm_expand_policies in net/xfrm/xfrm_policy.c can cause a refcount to be dropped twice.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-36879" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-36879" }, { "cve": "CVE-2022-36946", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "nfqnl_mangle in net/netfilter/nfnetlink_queue.c in the Linux kernel through 5.18.14 allows remote attackers to cause a denial of service (panic) because, in the case of an nf_queue verdict with a one-byte nfta_payload attribute, an skb_pull can encounter a negative skb-\u003elen.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-36946" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-36946" } ] }
ICSA-23-075-01
Vulnerability from csaf_cisa
Published
2023-03-31 17:50
Modified
2023-03-31 17:50
Summary
Siemens SCALANCE, RUGGEDCOM Third-Party
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to inject code or cause a denial-of-service condition.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Recommended Practices
Do not click web links or open attachments in unsolicited email messages.
Recommended Practices
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Recommended Practices
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
Recommended Practices
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to inject code or cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Do not click web links or open attachments in unsolicited email messages.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-419740: Multiple\tThird-Party Component Vulnerabilities in RUGGEDCOM and SCALANCE Products before V7.2 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-419740.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-075-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-075-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-075-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-075-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/Recommended-Practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "SSA-419740: Multiple\tThird-Party Component Vulnerabilities in RUGGEDCOM and SCALANCE Products before V7.2 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-419740.pdf" }, { "category": "external", "summary": "SSA-419740: Multiple\tThird-Party Component Vulnerabilities in RUGGEDCOM and SCALANCE Products before V7.2 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-419740.txt" } ], "title": "Siemens SCALANCE, RUGGEDCOM Third-Party", "tracking": { "current_release_date": "2023-03-31T17:50:48.679470Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-075-01", "initial_release_date": "2023-03-31T17:50:48.679470Z", "revision_history": [ { "date": "2023-03-31T17:50:48.679470Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2BA2" ] } } } ], "category": "product_name", "name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK6108-4AM00-2DA2" ] } } } ], "category": "product_name", "name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5804-0AP00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK5812-1AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)", "product_id": "CSAFPID-0005", "product_identification_helper": { "model_numbers": [ "6GK5812-1BA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)", "product_id": "CSAFPID-0006", "product_identification_helper": { "model_numbers": [ "6GK5816-1AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)", "product_id": "CSAFPID-0007", "product_identification_helper": { "model_numbers": [ "6GK5816-1BA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)", "product_id": "CSAFPID-0008", "product_identification_helper": { "model_numbers": [ "6GK5826-2AB00-2AB2" ] } } } ], "category": "product_name", "name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)", "product_id": "CSAFPID-0009", "product_identification_helper": { "model_numbers": [ "6GK5874-2AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)", "product_id": "CSAFPID-00010", "product_identification_helper": { "model_numbers": [ "6GK5874-3AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)", "product_id": "CSAFPID-00011", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)", "product_id": "CSAFPID-00012", "product_identification_helper": { "model_numbers": [ "6GK5876-3AA02-2EA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)", "product_id": "CSAFPID-00013", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA10-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (6GK5876-4AA10-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)", "product_id": "CSAFPID-00014", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2BA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)", "product_id": "CSAFPID-00015", "product_identification_helper": { "model_numbers": [ "6GK5876-4AA00-2DA2" ] } } } ], "category": "product_name", "name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)", "product_id": "CSAFPID-00016", "product_identification_helper": { "model_numbers": [ "6GK5853-2EA00-2DA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)", "product_id": "CSAFPID-00017", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3DA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)", "product_id": "CSAFPID-00018", "product_identification_helper": { "model_numbers": [ "6GK5856-2EA00-3AA1" ] } } } ], "category": "product_name", "name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE S615 (6GK5615-0AA00-2AA2)", "product_id": "CSAFPID-00019", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE S615 (6GK5615-0AA00-2AA2)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V7.2", "product": { "name": "SCALANCE S615 EEC (6GK5615-0AA01-2AA2)", "product_id": "CSAFPID-00020", "product_identification_helper": { "model_numbers": [ "6GK5615-0AA01-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE S615 EEC (6GK5615-0AA01-2AA2)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-25032", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-25032" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2018-25032" }, { "cve": "CVE-2019-1125", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "An information disclosure vulnerability exists when certain central processing units (CPU) speculatively access memory, aka \u0027Windows Kernel Information Disclosure Vulnerability\u0027. This CVE ID is unique from CVE-2019-1071, CVE-2019-1073.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-1125" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2019-1125" }, { "cve": "CVE-2021-4034", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A local privilege escalation vulnerability was found on polkit\u0027s pkexec utility. The pkexec application is a setuid tool designed to allow unprivileged users to run commands as privileged users according predefined policies. The current version of pkexec doesn\u0027t handle the calling parameters count correctly and ends trying to execute environment variables as commands. An attacker can leverage this by crafting environment variables in such a way it\u0027ll induce pkexec to execute arbitrary code. When successfully executed the attack can cause a local privilege escalation given unprivileged users administrative rights on the target machine.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-4034" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-4034" }, { "cve": "CVE-2021-4149", "cwe": { "id": "CWE-667", "name": "Improper Locking" }, "notes": [ { "category": "summary", "text": "A vulnerability was found in btrfs_alloc_tree_b in fs/btrfs/extent-tree.c in the Linux kernel due to an improper lock operation in btrfs. In this flaw, a user with a local privilege may cause a denial of service (DOS) due to a deadlock problem.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-4149" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-4149" }, { "cve": "CVE-2021-26401", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "LFENCE/JMP (mitigation V2-2) may not sufficiently mitigate CVE-2017-5715 on some AMD CPUs.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-26401" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-26401" }, { "cve": "CVE-2021-42373", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s man applet leads to denial of service when a section name is supplied but no page argument is given.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42373" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42373" }, { "cve": "CVE-2021-42374", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42374" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42375", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An incorrect handling of a special element in Busybox\u0027s ash applet leads to denial of service when processing a crafted shell command, due to the shell mistaking specific characters for reserved characters. This may be used for DoS under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42375" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42376", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s hush applet leads to denial of service when processing a crafted shell command, due to missing validation after a \\x03 delimiter character. This may be used for DoS under very rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42376" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42377", "cwe": { "id": "CWE-763", "name": "Release of Invalid Pointer or Reference" }, "notes": [ { "category": "summary", "text": "An attacker-controlled pointer free in Busybox\u0027s hush applet leads to denial of service and possible code execution when processing a crafted shell command, due to the shell mishandling the \u0026\u0026\u0026 string. This may be used for remote code execution under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42377" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42378", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42378" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42379" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42380" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42381" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42382" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42383" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42384" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42385" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-42386" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2021-42386" }, { "cve": "CVE-2022-0001", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Non-transparent sharing of branch predictor selectors between contexts in some Intel(R) Processors may allow an authorized user to potentially enable information disclosure via local access.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-0001" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-0001" }, { "cve": "CVE-2022-0002", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Non-transparent sharing of branch predictor within a context in some Intel(R) Processors may allow an authorized user to potentially enable information disclosure via local access.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-0002" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-0002" }, { "cve": "CVE-2022-0494", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "A kernel information leak flaw was identified in the scsi_ioctl function in drivers/scsi/scsi_ioctl.c in the Linux kernel. This flaw allows a local attacker with a special user privilege (CAP_SYS_ADMIN or CAP_SYS_RAWIO) to create issues with confidentiality.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-0494" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-0494" }, { "cve": "CVE-2022-0547", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "OpenVPN 2.1 until v2.4.12 and v2.5.6 may enable authentication bypass in external authentication plug-ins when more than one of them makes use of deferred authentication replies, which allows an external user to be granted access with only partially correct credentials.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-0547" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-0547" }, { "cve": "CVE-2022-1011", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u2019s FUSE filesystem in the way a user triggers write(). This flaw allows a local user to gain unauthorized access to data from the FUSE filesystem, resulting in privilege escalation.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1011" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1011" }, { "cve": "CVE-2022-1016", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel in net/netfilter/nf_tables_core.c:nft_do_chain, which can cause a use-after-free. This issue needs to handle \u0027return\u0027 with proper preconditions, as it can lead to a kernel information leak problem caused by a local, unprivileged attacker.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1016" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1016" }, { "cve": "CVE-2022-1198", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerabilitity was discovered in drivers/net/hamradio/6pack.c of linux that allows an attacker to crash linux kernel by simulating ax25 device using 6pack driver from user space.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1198" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1198" }, { "cve": "CVE-2022-1199", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel. This flaw allows an attacker to crash the Linux kernel by simulating amateur radio from the user space, resulting in a null-ptr-deref vulnerability and a use-after-free vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1199" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1199" }, { "cve": "CVE-2022-1292", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The c_rehash script does not properly sanitise shell metacharacters to prevent command injection.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1292" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1292" }, { "cve": "CVE-2022-1304", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read/write vulnerability was found in e2fsprogs 1.46.5. This issue leads to a segmentation fault and possibly arbitrary code execution via a specially crafted filesystem.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1304" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1304" }, { "cve": "CVE-2022-1343", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "Under certain circumstances, the command line OCSP verify function reports successful verification when the varification in fact failed. In this case the incorrect successful response will also be accompanied by error messages showing the failure and contradicting the apparently successful result.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1343" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1343" }, { "cve": "CVE-2022-1353", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "A vulnerability was found in the pfkey_register function in net/key/af_key.c in the Linux kernel. This flaw allows a local, unprivileged user to gain access to kernel memory, leading to a system crash or a leak of internal kernel information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1353" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1353" }, { "cve": "CVE-2022-1473", "cwe": { "id": "CWE-404", "name": "Improper Resource Shutdown or Release" }, "notes": [ { "category": "summary", "text": "The used OpenSSL version improperly reuses memory when decoding certificates or keys. This can lead to a process termination and Denial of Service for long lived processes.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1473" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1473" }, { "cve": "CVE-2022-1516", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference flaw was found in the Linux kernel\u2019s X.25 set of standardized network protocols functionality in the way a user terminates their session using a simulated Ethernet card and continued usage of this connection. This flaw allows a local user to crash the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1516" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1516" }, { "cve": "CVE-2022-1652", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Linux Kernel could allow a local attacker to execute arbitrary code on the system, caused by a concurrency use-after-free flaw in the bad_flp_intr function. By executing a specially-crafted program, an attacker could exploit this vulnerability to execute arbitrary code or cause a denial of service condition on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1652" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1652" }, { "cve": "CVE-2022-1729", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "A race condition was found the Linux kernel in perf_event_open() which can be exploited by an unprivileged user to gain root privileges. The bug allows to build several exploit primitives such as kernel address information leak, arbitrary execution, etc.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1729" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1729" }, { "cve": "CVE-2022-1734", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw in Linux Kernel found in nfcmrvl_nci_unregister_dev() in drivers/nfc/nfcmrvl/main.c can lead to use after free both read or write when non synchronized between cleanup routine and firmware download routine.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1734" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1734" }, { "cve": "CVE-2022-1974", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u0027s NFC core functionality due to a race condition between kobject creation and delete. This vulnerability allows a local attacker with CAP_NET_ADMIN privilege to leak kernel information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1974" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1974" }, { "cve": "CVE-2022-1975", "cwe": { "id": "CWE-248", "name": "Uncaught Exception" }, "notes": [ { "category": "summary", "text": "There is a sleep-in-atomic bug in /net/nfc/netlink.c that allows an attacker to crash the Linux kernel by simulating a nfc device from user-space.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1975" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-1975" }, { "cve": "CVE-2022-2380", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Linux kernel was found vulnerable out of bounds memory access in the drivers/video/fbdev/sm712fb.c:smtcfb_read() function. The vulnerability could result in local attackers being able to crash the kernel.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2380" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-2380" }, { "cve": "CVE-2022-2588", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Zhenpeng Lin discovered that the network packet scheduler implementation in the Linux kernel did not properly remove all references to a route filter before freeing it in some situations. A local attacker could use this to cause a denial of service (system crash) or execute arbitrary code.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2588" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-2588" }, { "cve": "CVE-2022-2639", "cwe": { "id": "CWE-191", "name": "Integer Underflow (Wrap or Wraparound)" }, "notes": [ { "category": "summary", "text": "An integer coercion error was found in the openvswitch kernel module. Given a sufficiently large number of actions, while copying and reserving memory for a new action of a new flow, the reserve_sfa_size() function does not return -EMSGSIZE as expected, potentially leading to an out-of-bounds write access. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2639" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-2639" }, { "cve": "CVE-2022-20158", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "In bdi_put and bdi_unregister of backing-dev.c, there is a possible memory corruption due to a use after free. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-182815710References: Upstream kernel", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-20158" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-20158" }, { "cve": "CVE-2022-23036", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23036" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23036" }, { "cve": "CVE-2022-23037", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23037" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23037" }, { "cve": "CVE-2022-23038", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23038" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23038" }, { "cve": "CVE-2022-23039", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23039" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23039" }, { "cve": "CVE-2022-23040", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23040" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23040" }, { "cve": "CVE-2022-23041", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23041" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23041" }, { "cve": "CVE-2022-23042", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "Linux PV device frontends vulnerable to attacks by backends [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn\u0027t check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23042" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23042" }, { "cve": "CVE-2022-23308", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "valid.c in libxml2 before 2.9.13 has a use-after-free of ID and IDREF attributes.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-23308" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-23308" }, { "cve": "CVE-2022-26490", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "st21nfca_connectivity_event_received in drivers/nfc/st21nfca/se.c in the Linux kernel through 5.16.12 has EVT_TRANSACTION buffer overflows because of untrusted length parameters.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-26490" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-26490" }, { "cve": "CVE-2022-28356", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "In the Linux kernel before 5.17.1, a refcount leak bug was found in net/llc/af_llc.c.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-28356" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-28356" }, { "cve": "CVE-2022-28390", "cwe": { "id": "CWE-415", "name": "Double Free" }, "notes": [ { "category": "summary", "text": "ems_usb_start_xmit in drivers/net/can/usb/ems_usb.c in the Linux kernel through 5.17.1 has a double free.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-28390" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-28390" }, { "cve": "CVE-2022-30065", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox 1.35-x\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-30065" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-30065" }, { "cve": "CVE-2022-30594", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "summary", "text": "The Linux kernel before 5.17.2 mishandles seccomp permissions. The PTRACE_SEIZE code path allows attackers to bypass intended restrictions on setting the PT_SUSPEND_SECCOMP flag.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-30594" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-30594" }, { "cve": "CVE-2022-32205", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "A malicious server can serve excessive amounts of \"Set-Cookie:\" headers in a HTTP response to curl and curl \u003c 7.84.0 stores all of them. A sufficiently large amount of (big) cookies make subsequent HTTP requests to this, or other servers to which the cookies match, create requests that become larger than the threshold that curl uses internally to avoid sending crazy large requests (1048576 bytes) and instead returns an error.This denial state might remain for as long as the same cookies are kept, match and haven\u0027t expired. Due to cookie matching rules, a server on \"foo.example.com\" can set cookies that also would match for \"bar.example.com\", making it it possible for a \"sister server\" to effectively cause a denial of service for a sibling site on the same second level domain using this method.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32205" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32205" }, { "cve": "CVE-2022-32206", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "curl \u003c 7.84.0 supports \"chained\" HTTP compression algorithms, meaning that a serverresponse can be compressed multiple times and potentially with different algorithms. The number of acceptable \"links\" in this \"decompression chain\" was unbounded, allowing a malicious server to insert a virtually unlimited number of compression steps.The use of such a decompression chain could result in a \"malloc bomb\", makingcurl end up spending enormous amounts of allocated heap memory, or trying toand returning out of memory errors.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32206" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32206" }, { "cve": "CVE-2022-32207", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "When curl \u003c 7.84.0 saves cookies, alt-svc and hsts data to local files, it makes the operation atomic by finalizing the operation with a rename from a temporary name to the final target file name.In that rename operation, it might accidentally *widen* the permissions for the target file, leaving the updated file accessible to more users than intended.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32207" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32207" }, { "cve": "CVE-2022-32208", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "When curl \u003c 7.84.0 does FTP transfers secured by krb5, it handles message verification failures wrongly. This flaw makes it possible for a Man-In-The-Middle attack to go unnoticed and even allows it to inject data to the client.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32208" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32208" }, { "cve": "CVE-2022-32296", "cwe": { "id": "CWE-203", "name": "Observable Discrepancy" }, "notes": [ { "category": "summary", "text": "The Linux kernel before 5.17.9 allows TCP servers to identify clients by observing what source ports are used. This occurs because of use of Algorithm 4 (\"Double-Hash Port Selection Algorithm\") of RFC 6056.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32296" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32296" }, { "cve": "CVE-2022-32981", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "An issue was discovered in the Linux kernel through 5.18.3 on powerpc 32-bit platforms. There is a buffer overflow in ptrace PEEKUSER and POKEUSER (aka PEEKUSR and POKEUSR) when accessing floating point registers.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32981" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-32981" }, { "cve": "CVE-2022-33981", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "drivers/block/floppy.c in the Linux kernel before 5.17.6 is vulnerable to a denial of service, because of a concurrency use-after-free flaw after deallocating raw_cmd in the raw_cmd_ioctl function.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-33981" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-33981" }, { "cve": "CVE-2022-35252", "cwe": { "id": "CWE-1286", "name": "Improper Validation of Syntactic Correctness of Input" }, "notes": [ { "category": "summary", "text": "When curl is used to retrieve and parse cookies from a HTTP(S) server, itaccepts cookies using control codes that when later are sent back to a HTTPserver might make the server return 400 responses. Effectively allowing a\"sister site\" to deny service to all siblings.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-35252" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-35252" }, { "cve": "CVE-2022-36879", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An issue was discovered in the Linux kernel through 5.18.14. xfrm_expand_policies in net/xfrm/xfrm_policy.c can cause a refcount to be dropped twice.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-36879" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-36879" }, { "cve": "CVE-2022-36946", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "nfqnl_mangle in net/netfilter/nfnetlink_queue.c in the Linux kernel through 5.18.14 allows remote attackers to cause a denial of service (panic) because, in the case of an nf_queue verdict with a one-byte nfta_payload attribute, an skb_pull can encounter a negative skb-\u003elen.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-36946" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V7.2 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ], "url": "https://support.industry.siemens.com/cs/document/109817007/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020" ] } ], "title": "CVE-2022-36946" } ] }
ICSA-23-166-12
Vulnerability from csaf_cisa
Published
2023-06-13 00:00
Modified
2023-06-13 00:00
Summary
Siemens SINAMICS Medium Voltage Products
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Summary
Several SINAMICS MV (medium voltage) products are affected by multiple vulnerabilities in the integrated SCALANCE S615 device, as documented in SSA-419740 (
https://cert-portal.siemens.com/productcert/html/ssa-419740.html).
Siemens recommends to update the firmware of the integrated SCALANCE S615 device to the latest version. Siemens recommends specific countermeasures for products where the firmware update is not, or not yet applied.
Additional considerations regarding the specific impact of the vulnerabilities to SINAMICS MV products can be found in the chapter "Additional Information".
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimizing network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices
Locating control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices
When remote access is required, using more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Exploitability
No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "summary", "text": "Several SINAMICS MV (medium voltage) products are affected by multiple vulnerabilities in the integrated SCALANCE S615 device, as documented in SSA-419740 (\nhttps://cert-portal.siemens.com/productcert/html/ssa-419740.html).\nSiemens recommends to update the firmware of the integrated SCALANCE S615 device to the latest version. Siemens recommends specific countermeasures for products where the firmware update is not, or not yet applied.\n\nAdditional considerations regarding the specific impact of the vulnerabilities to SINAMICS MV products can be found in the chapter \"Additional Information\".", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimizing network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locating control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, using more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "\u200bNo known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "other", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-942865: Multiple Vulnerabilities in the Integrated SCALANCE S615 of SINAMICS Medium Voltage Products - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-942865.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-166-12 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-166-12.json" }, { "category": "self", "summary": "SSA-942865: Multiple Vulnerabilities in the Integrated SCALANCE S615 of SINAMICS Medium Voltage Products - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-942865.html" }, { "category": "self", "summary": "SSA-942865: Multiple Vulnerabilities in the Integrated SCALANCE S615 of SINAMICS Medium Voltage Products - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-942865.pdf" }, { "category": "self", "summary": "SSA-942865: Multiple Vulnerabilities in the Integrated SCALANCE S615 of SINAMICS Medium Voltage Products - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-942865.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-166-12 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-12" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SINAMICS Medium Voltage Products", "tracking": { "current_release_date": "2023-06-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-166-12", "initial_release_date": "2023-06-13T00:00:00.000000Z", "revision_history": [ { "date": "2023-06-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SINAMICS GL150", "product_id": "1" } } ], "category": "product_name", "name": "SINAMICS GL150" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SINAMICS PERFECT HARMONY GH180 6SR5", "product_id": "2" } } ], "category": "product_name", "name": "SINAMICS PERFECT HARMONY GH180 6SR5" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SINAMICS SL150", "product_id": "3" } } ], "category": "product_name", "name": "SINAMICS SL150" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-25032", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2018-25032" }, { "cve": "CVE-2021-42374", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42378", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-42386" }, { "cve": "CVE-2022-0547", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "OpenVPN 2.1 until v2.4.12 and v2.5.6 may enable authentication bypass in external authentication plug-ins when more than one of them makes use of deferred authentication replies, which allows an external user to be granted access with only partially correct credentials.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-0547" }, { "cve": "CVE-2022-1199", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel. This flaw allows an attacker to crash the Linux kernel by simulating amateur radio from the user space, resulting in a null-ptr-deref vulnerability and a use-after-free vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-1199" }, { "cve": "CVE-2022-1292", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The c_rehash script does not properly sanitise shell metacharacters to prevent command injection.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-1292" }, { "cve": "CVE-2022-1343", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "Under certain circumstances, the command line OCSP verify function reports successful verification when the verification in fact failed. In this case the incorrect successful response will also be accompanied by error messages showing the failure and contradicting the apparently successful result.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-1343" }, { "cve": "CVE-2022-1473", "cwe": { "id": "CWE-404", "name": "Improper Resource Shutdown or Release" }, "notes": [ { "category": "summary", "text": "The used OpenSSL version improperly reuses memory when decoding certificates or keys. This can lead to a process termination and Denial of Service for long lived processes.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-1473" }, { "cve": "CVE-2022-23308", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "valid.c in libxml2 before 2.9.13 has a use-after-free of ID and IDREF attributes.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-23308" }, { "cve": "CVE-2022-32205", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "A malicious server can serve excessive amounts of \"Set-Cookie:\" headers in a HTTP response to curl and curl \u003c 7.84.0 stores all of them. A sufficiently large amount of (big) cookies make subsequent HTTP requests to this, or other servers to which the cookies match, create requests that become larger than the threshold that curl uses internally to avoid sending crazy large requests (1048576 bytes) and instead returns an error.This denial state might remain for as long as the same cookies are kept, match and haven\u0027t expired. Due to cookie matching rules, a server on \"foo.example.com\" can set cookies that also would match for \"bar.example.com\", making it it possible for a \"sister server\" to effectively cause a denial of service for a sibling site on the same second level domain using this method.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-32205" }, { "cve": "CVE-2022-32206", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "summary", "text": "curl \u003c 7.84.0 supports \"chained\" HTTP compression algorithms, meaning that a serverresponse can be compressed multiple times and potentially with different algorithms. The number of acceptable \"links\" in this \"decompression chain\" was unbounded, allowing a malicious server to insert a virtually unlimited number of compression steps.The use of such a decompression chain could result in a \"malloc bomb\", makingcurl end up spending enormous amounts of allocated heap memory, or trying toand returning out of memory errors.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-32206" }, { "cve": "CVE-2022-32207", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "When curl \u003c 7.84.0 saves cookies, alt-svc and hsts data to local files, it makes the operation atomic by finalizing the operation with a rename from a temporary name to the final target file name.In that rename operation, it might accidentally *widen* the permissions for the target file, leaving the updated file accessible to more users than intended.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-32207" }, { "cve": "CVE-2022-32208", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "When curl \u003c 7.84.0 does FTP transfers secured by krb5, it handles message verification failures wrongly. This flaw makes it possible for a Man-In-The-Middle attack to go unnoticed and even allows it to inject data to the client.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-32208" }, { "cve": "CVE-2022-35252", "cwe": { "id": "CWE-1286", "name": "Improper Validation of Syntactic Correctness of Input" }, "notes": [ { "category": "summary", "text": "When curl is used to retrieve and parse cookies from a HTTP(S) server, itaccepts cookies using control codes that when later are sent back to a HTTPserver might make the server return 400 responses. Effectively allowing a\"sister site\" to deny service to all siblings.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-35252" }, { "cve": "CVE-2022-36946", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "nfqnl_mangle in net/netfilter/nfnetlink_queue.c in the Linux kernel through 5.18.14 allows remote attackers to cause a denial of service (panic) because, in the case of an nf_queue verdict with a one-byte nfta_payload attribute, an skb_pull can encounter a negative skb-\u003elen.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Restrict physical access to the affected drives, also to their Ethernet Port included on the front of the control door", "product_ids": [ "1", "2", "3" ] }, { "category": "mitigation", "details": "Disconnect any direct network connection to the integrated SCALANCE S615 device", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update the firmware of the integrated SCALANCE S615 device to V7.2 or later version", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2022-36946" } ] }
WID-SEC-W-2022-2028
Vulnerability from csaf_certbund
Published
2021-11-09 23:00
Modified
2024-07-04 22:00
Summary
BusyBox: Mehrere Schwachstellen
Notes
Das BSI ist als Anbieter für die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch dafür verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgfältig im Einzelfall zu prüfen.
Produktbeschreibung
BusyBox ist ein Computerprogramm, das verschiedene Standard-Unix-Dienstprogramme in einem einzelnen Programm vereint.
Angriff
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in BusyBox ausnutzen, um einen Denial of Service Angriff durchzuführen, Informationen offenzulegen oder beliebigen Code auszuführen.
Betroffene Betriebssysteme
- Linux
- Sonstiges
- UNIX
{ "document": { "aggregate_severity": { "text": "hoch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "BusyBox ist ein Computerprogramm, das verschiedene Standard-Unix-Dienstprogramme in einem einzelnen Programm vereint.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in BusyBox ausnutzen, um einen Denial of Service Angriff durchzuf\u00fchren, Informationen offenzulegen oder beliebigen Code auszuf\u00fchren.", "title": "Angriff" }, { "category": "general", "text": "- Linux\n- Sonstiges\n- UNIX", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2022-2028 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2021/wid-sec-w-2022-2028.json" }, { "category": "self", "summary": "WID-SEC-2022-2028 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2022-2028" }, { "category": "external", "summary": "JFrog Blog vom 2021-11-09", "url": "https://jfrog.com/blog/unboxing-busybox-14-new-vulnerabilities-uncovered-by-claroty-and-jfrog/" }, { "category": "external", "summary": "Ubuntu Security Notice USN-5179-1 vom 2021-12-07", "url": "https://ubuntu.com/security/notices/USN-5179-1" }, { "category": "external", "summary": "Amazon Linux Security Advisory ALAS-2022-1558 vom 2022-01-20", "url": "https://alas.aws.amazon.com/ALAS-2022-1558.html" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2022:0135-1 vom 2022-01-20", "url": "https://lists.suse.com/pipermail/sle-security-updates/2022-January/010031.html" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2022:0135-2 vom 2022-02-14", "url": "https://lists.suse.com/pipermail/sle-security-updates/2022-February/010220.html" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2022:3959-1 vom 2022-11-11", "url": "https://lists.suse.com/pipermail/sle-security-updates/2022-November/012904.html" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2022:4253-1 vom 2022-11-28", "url": "https://lists.suse.com/pipermail/sle-security-updates/2022-November/013126.html" }, { "category": "external", "summary": "Gentoo Linux Security Advisory GLSA-202407-17 vom 2024-07-05", "url": "https://security.gentoo.org/glsa/202407-17" } ], "source_lang": "en-US", "title": "BusyBox: Mehrere Schwachstellen", "tracking": { "current_release_date": "2024-07-04T22:00:00.000+00:00", "generator": { "date": "2024-07-05T11:33:01.730+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2022-2028", "initial_release_date": "2021-11-09T23:00:00.000+00:00", "revision_history": [ { "date": "2021-11-09T23:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" }, { "date": "2021-11-16T23:00:00.000+00:00", "number": "2", "summary": "Referenz(en) aufgenommen: FEDORA-2021-5A95823596" }, { "date": "2021-12-07T23:00:00.000+00:00", "number": "3", "summary": "Neue Updates von Ubuntu aufgenommen" }, { "date": "2022-01-19T23:00:00.000+00:00", "number": "4", "summary": "Neue Updates von Amazon aufgenommen" }, { "date": "2022-01-20T23:00:00.000+00:00", "number": "5", "summary": "Neue Updates von SUSE aufgenommen" }, { "date": "2022-02-14T23:00:00.000+00:00", "number": "6", "summary": "Neue Updates von SUSE aufgenommen" }, { "date": "2022-11-13T23:00:00.000+00:00", "number": "7", "summary": "Neue Updates von SUSE aufgenommen" }, { "date": "2022-11-28T23:00:00.000+00:00", "number": "8", "summary": "Neue Updates von SUSE aufgenommen" }, { "date": "2024-07-04T22:00:00.000+00:00", "number": "9", "summary": "Neue Updates von Gentoo aufgenommen" } ], "status": "final", "version": "9" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "Amazon Linux 2", "product": { "name": "Amazon Linux 2", "product_id": "398363", "product_identification_helper": { "cpe": "cpe:/o:amazon:linux_2:-" } } } ], "category": "vendor", "name": "Amazon" }, { "branches": [ { "category": "product_name", "name": "Gentoo Linux", "product": { "name": "Gentoo Linux", "product_id": "T012167", "product_identification_helper": { "cpe": "cpe:/o:gentoo:linux:-" } } } ], "category": "vendor", "name": "Gentoo" }, { "branches": [ { "category": "product_name", "name": "Open Source BusyBox", "product": { "name": "Open Source BusyBox", "product_id": "T013362", "product_identification_helper": { "cpe": "cpe:/a:busybox:busybox:-" } } } ], "category": "vendor", "name": "Open Source" }, { "branches": [ { "category": "product_name", "name": "SUSE Linux", "product": { "name": "SUSE Linux", "product_id": "T002207", "product_identification_helper": { "cpe": "cpe:/o:suse:suse_linux:-" } } } ], "category": "vendor", "name": "SUSE" }, { "branches": [ { "category": "product_name", "name": "Ubuntu Linux", "product": { "name": "Ubuntu Linux", "product_id": "T000126", "product_identification_helper": { "cpe": "cpe:/o:canonical:ubuntu_linux:-" } } } ], "category": "vendor", "name": "Ubuntu" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-42373", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein entfernter anonymer oder authentisierter Angreifer kann diese Schwachstellen ausnutzen, um Informationen offenzulegen und einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42373" }, { "cve": "CVE-2021-42374", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein entfernter anonymer oder authentisierter Angreifer kann diese Schwachstellen ausnutzen, um Informationen offenzulegen und einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42375", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein entfernter anonymer oder authentisierter Angreifer kann diese Schwachstellen ausnutzen, um Informationen offenzulegen und einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42376", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein entfernter anonymer oder authentisierter Angreifer kann diese Schwachstellen ausnutzen, um Informationen offenzulegen und einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42377", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42378", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42386" } ] }
WID-SEC-W-2023-1432
Vulnerability from csaf_certbund
Published
2023-06-12 22:00
Modified
2023-06-22 22:00
Summary
Siemens SIMATIC S7: Mehrere Schwachstellen
Notes
Das BSI ist als Anbieter für die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch dafür verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgfältig im Einzelfall zu prüfen.
Produktbeschreibung
Die SIMATIC S7 ist eine Serie von SPS (Speicherprogrammierbare Steuerungen) für Automatisierungsanwendungen.
Angriff
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien zu erweitern und Daten zu manipulieren.
Betroffene Betriebssysteme
- BIOS/Firmware
{ "document": { "aggregate_severity": { "text": "kritisch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "Die SIMATIC S7 ist eine Serie von SPS (Speicherprogrammierbare Steuerungen) f\u00fcr Automatisierungsanwendungen.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren.", "title": "Angriff" }, { "category": "general", "text": "- BIOS/Firmware", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-1432 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-1432.json" }, { "category": "self", "summary": "WID-SEC-2023-1432 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-1432" }, { "category": "external", "summary": "Ubuntu Security Notice USN-6187-1 vom 2023-06-22", "url": "https://ubuntu.com/security/notices/USN-6187-1" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-06-12", "url": "https://cert-portal.siemens.com/productcert/html/ssa-831302.html" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-06-12", "url": "https://cert-portal.siemens.com/productcert/html/ssa-794697.html" } ], "source_lang": "en-US", "title": "Siemens SIMATIC S7: Mehrere Schwachstellen", "tracking": { "current_release_date": "2023-06-22T22:00:00.000+00:00", "generator": { "date": "2024-02-15T17:30:48.504+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2023-1432", "initial_release_date": "2023-06-12T22:00:00.000+00:00", "revision_history": [ { "date": "2023-06-12T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" }, { "date": "2023-06-22T22:00:00.000+00:00", "number": "2", "summary": "Neue Updates von Ubuntu aufgenommen" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "Siemens SIMATIC S7 1500 TM MFP", "product": { "name": "Siemens SIMATIC S7 1500 TM MFP", "product_id": "T028071", "product_identification_helper": { "cpe": "cpe:/h:siemens:simatic_s7:1500_tm_mfp" } } } ], "category": "vendor", "name": "Siemens" }, { "branches": [ { "category": "product_name", "name": "Ubuntu Linux", "product": { "name": "Ubuntu Linux", "product_id": "T000126", "product_identification_helper": { "cpe": "cpe:/o:canonical:ubuntu_linux:-" } } } ], "category": "vendor", "name": "Ubuntu" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-26607", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-26607" }, { "cve": "CVE-2023-23559", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-23559" }, { "cve": "CVE-2023-23455", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-23455" }, { "cve": "CVE-2023-23454", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-23454" }, { "cve": "CVE-2023-1095", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-1095" }, { "cve": "CVE-2023-1077", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-1077" }, { "cve": "CVE-2023-1073", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-1073" }, { "cve": "CVE-2023-0590", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0590" }, { "cve": "CVE-2023-0466", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0466" }, { "cve": "CVE-2023-0465", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0465" }, { "cve": "CVE-2023-0464", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0464" }, { "cve": "CVE-2023-0394", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0394" }, { "cve": "CVE-2023-0286", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0286" }, { "cve": "CVE-2023-0215", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0215" }, { "cve": "CVE-2023-0179", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0179" }, { "cve": "CVE-2022-47946", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-47946" }, { "cve": "CVE-2022-47929", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-47929" }, { "cve": "CVE-2022-47520", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-47520" }, { "cve": "CVE-2022-47518", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-47518" }, { "cve": "CVE-2022-4662", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4662" }, { "cve": "CVE-2022-4450", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4450" }, { "cve": "CVE-2022-4378", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4378" }, { "cve": "CVE-2022-43750", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-43750" }, { "cve": "CVE-2022-4304", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4304" }, { "cve": "CVE-2022-42896", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42896" }, { "cve": "CVE-2022-42895", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42895" }, { "cve": "CVE-2022-42722", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42722" }, { "cve": "CVE-2022-42721", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42721" }, { "cve": "CVE-2022-42720", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42720" }, { "cve": "CVE-2022-42719", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42719" }, { "cve": "CVE-2022-42703", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42703" }, { "cve": "CVE-2022-42432", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42432" }, { "cve": "CVE-2022-42329", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42329" }, { "cve": "CVE-2022-42328", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42328" }, { "cve": "CVE-2022-41850", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-41850" }, { "cve": "CVE-2022-41849", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-41849" }, { "cve": "CVE-2022-41674", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-41674" }, { "cve": "CVE-2022-4139", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4139" }, { "cve": "CVE-2022-4129", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4129" }, { "cve": "CVE-2022-41222", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-41222" }, { "cve": "CVE-2022-41218", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-41218" }, { "cve": "CVE-2022-4095", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4095" }, { "cve": "CVE-2022-40768", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-40768" }, { "cve": "CVE-2022-40307", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-40307" }, { "cve": "CVE-2022-39190", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-39190" }, { "cve": "CVE-2022-39188", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-39188" }, { "cve": "CVE-2022-36946", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-36946" }, { "cve": "CVE-2022-36879", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-36879" }, { "cve": "CVE-2022-3649", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3649" }, { "cve": "CVE-2022-3646", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3646" }, { "cve": "CVE-2022-3635", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3635" }, { "cve": "CVE-2022-3633", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3633" }, { "cve": "CVE-2022-3629", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3629" }, { "cve": "CVE-2022-36280", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-36280" }, { "cve": "CVE-2022-3628", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3628" }, { "cve": "CVE-2022-3625", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3625" }, { "cve": "CVE-2022-3621", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3621" }, { "cve": "CVE-2022-36123", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-36123" }, { "cve": "CVE-2022-3606", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3606" }, { "cve": "CVE-2022-3594", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3594" }, { "cve": "CVE-2022-3586", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3586" }, { "cve": "CVE-2022-3565", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3565" }, { "cve": "CVE-2022-3564", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3564" }, { "cve": "CVE-2022-3545", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3545" }, { "cve": "CVE-2022-3534", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3534" }, { "cve": "CVE-2022-3524", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3524" }, { "cve": "CVE-2022-3521", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3521" }, { "cve": "CVE-2022-34918", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-34918" }, { "cve": "CVE-2022-3435", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3435" }, { "cve": "CVE-2022-3303", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3303" }, { "cve": "CVE-2022-32296", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-32296" }, { "cve": "CVE-2022-32250", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-32250" }, { "cve": "CVE-2022-3169", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3169" }, { "cve": "CVE-2022-3115", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3115" }, { "cve": "CVE-2022-3104", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3104" }, { "cve": "CVE-2022-3028", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3028" }, { "cve": "CVE-2022-30065", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-30065" }, { "cve": "CVE-2022-2978", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2978" }, { "cve": "CVE-2022-2959", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2959" }, { "cve": "CVE-2022-2905", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2905" }, { "cve": "CVE-2022-28391", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-28391" }, { "cve": "CVE-2022-2663", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2663" }, { "cve": "CVE-2022-26373", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-26373" }, { "cve": "CVE-2022-2602", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2602" }, { "cve": "CVE-2022-2588", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2588" }, { "cve": "CVE-2022-2586", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2586" }, { "cve": "CVE-2022-2585", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2585" }, { "cve": "CVE-2022-2503", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2503" }, { "cve": "CVE-2022-2327", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2327" }, { "cve": "CVE-2022-23219", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-23219" }, { "cve": "CVE-2022-23218", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-23218" }, { "cve": "CVE-2022-2274", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2274" }, { "cve": "CVE-2022-2153", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2153" }, { "cve": "CVE-2022-21505", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-21505" }, { "cve": "CVE-2022-21233", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-21233" }, { "cve": "CVE-2022-21166", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-21166" }, { "cve": "CVE-2022-21125", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-21125" }, { "cve": "CVE-2022-21123", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-21123" }, { "cve": "CVE-2022-2097", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2097" }, { "cve": "CVE-2022-2078", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2078" }, { "cve": "CVE-2022-2068", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2068" }, { "cve": "CVE-2022-20572", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-20572" }, { "cve": "CVE-2022-20566", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-20566" }, { "cve": "CVE-2022-20422", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-20422" }, { "cve": "CVE-2022-20421", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-20421" }, { "cve": "CVE-2022-1882", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1882" }, { "cve": "CVE-2022-1852", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1852" }, { "cve": "CVE-2022-1679", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1679" }, { "cve": "CVE-2022-1473", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1473" }, { "cve": "CVE-2022-1462", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1462" }, { "cve": "CVE-2022-1434", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1434" }, { "cve": "CVE-2022-1343", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1343" }, { "cve": "CVE-2022-1292", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1292" }, { "cve": "CVE-2022-1184", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1184" }, { "cve": "CVE-2022-1012", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1012" }, { "cve": "CVE-2022-0171", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-0171" }, { "cve": "CVE-2021-42386", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42386" }, { "cve": "CVE-2021-42385", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42384", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42383", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42382", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42381", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42380", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42379", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42378", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42377", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42376", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42375", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42374", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42373", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42373" }, { "cve": "CVE-2021-4037", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-4037" }, { "cve": "CVE-2021-3999", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-3999" }, { "cve": "CVE-2021-3998", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-3998" }, { "cve": "CVE-2021-38604", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-38604" }, { "cve": "CVE-2021-3759", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-3759" }, { "cve": "CVE-2021-35942", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-35942" }, { "cve": "CVE-2021-33655", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-33655" }, { "cve": "CVE-2021-33574", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-33574" }, { "cve": "CVE-2021-3326", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-3326" }, { "cve": "CVE-2021-28831", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-28831" }, { "cve": "CVE-2021-27645", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-27645" }, { "cve": "CVE-2021-20269", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-20269" }, { "cve": "CVE-2020-29562", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2020-29562" }, { "cve": "CVE-2020-27618", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2020-27618" }, { "cve": "CVE-2020-1752", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2020-1752" }, { "cve": "CVE-2020-10029", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2020-10029" }, { "cve": "CVE-2019-25013", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2019-25013" }, { "cve": "CVE-2018-13405", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2018-13405" }, { "cve": "CVE-2016-10228", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2016-10228" } ] }
wid-sec-w-2022-2028
Vulnerability from csaf_certbund
Published
2021-11-09 23:00
Modified
2024-07-04 22:00
Summary
BusyBox: Mehrere Schwachstellen
Notes
Das BSI ist als Anbieter für die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch dafür verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgfältig im Einzelfall zu prüfen.
Produktbeschreibung
BusyBox ist ein Computerprogramm, das verschiedene Standard-Unix-Dienstprogramme in einem einzelnen Programm vereint.
Angriff
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in BusyBox ausnutzen, um einen Denial of Service Angriff durchzuführen, Informationen offenzulegen oder beliebigen Code auszuführen.
Betroffene Betriebssysteme
- Linux
- Sonstiges
- UNIX
{ "document": { "aggregate_severity": { "text": "hoch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "BusyBox ist ein Computerprogramm, das verschiedene Standard-Unix-Dienstprogramme in einem einzelnen Programm vereint.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in BusyBox ausnutzen, um einen Denial of Service Angriff durchzuf\u00fchren, Informationen offenzulegen oder beliebigen Code auszuf\u00fchren.", "title": "Angriff" }, { "category": "general", "text": "- Linux\n- Sonstiges\n- UNIX", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2022-2028 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2021/wid-sec-w-2022-2028.json" }, { "category": "self", "summary": "WID-SEC-2022-2028 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2022-2028" }, { "category": "external", "summary": "JFrog Blog vom 2021-11-09", "url": "https://jfrog.com/blog/unboxing-busybox-14-new-vulnerabilities-uncovered-by-claroty-and-jfrog/" }, { "category": "external", "summary": "Ubuntu Security Notice USN-5179-1 vom 2021-12-07", "url": "https://ubuntu.com/security/notices/USN-5179-1" }, { "category": "external", "summary": "Amazon Linux Security Advisory ALAS-2022-1558 vom 2022-01-20", "url": "https://alas.aws.amazon.com/ALAS-2022-1558.html" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2022:0135-1 vom 2022-01-20", "url": "https://lists.suse.com/pipermail/sle-security-updates/2022-January/010031.html" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2022:0135-2 vom 2022-02-14", "url": "https://lists.suse.com/pipermail/sle-security-updates/2022-February/010220.html" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2022:3959-1 vom 2022-11-11", "url": "https://lists.suse.com/pipermail/sle-security-updates/2022-November/012904.html" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2022:4253-1 vom 2022-11-28", "url": "https://lists.suse.com/pipermail/sle-security-updates/2022-November/013126.html" }, { "category": "external", "summary": "Gentoo Linux Security Advisory GLSA-202407-17 vom 2024-07-05", "url": "https://security.gentoo.org/glsa/202407-17" } ], "source_lang": "en-US", "title": "BusyBox: Mehrere Schwachstellen", "tracking": { "current_release_date": "2024-07-04T22:00:00.000+00:00", "generator": { "date": "2024-07-05T11:33:01.730+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2022-2028", "initial_release_date": "2021-11-09T23:00:00.000+00:00", "revision_history": [ { "date": "2021-11-09T23:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" }, { "date": "2021-11-16T23:00:00.000+00:00", "number": "2", "summary": "Referenz(en) aufgenommen: FEDORA-2021-5A95823596" }, { "date": "2021-12-07T23:00:00.000+00:00", "number": "3", "summary": "Neue Updates von Ubuntu aufgenommen" }, { "date": "2022-01-19T23:00:00.000+00:00", "number": "4", "summary": "Neue Updates von Amazon aufgenommen" }, { "date": "2022-01-20T23:00:00.000+00:00", "number": "5", "summary": "Neue Updates von SUSE aufgenommen" }, { "date": "2022-02-14T23:00:00.000+00:00", "number": "6", "summary": "Neue Updates von SUSE aufgenommen" }, { "date": "2022-11-13T23:00:00.000+00:00", "number": "7", "summary": "Neue Updates von SUSE aufgenommen" }, { "date": "2022-11-28T23:00:00.000+00:00", "number": "8", "summary": "Neue Updates von SUSE aufgenommen" }, { "date": "2024-07-04T22:00:00.000+00:00", "number": "9", "summary": "Neue Updates von Gentoo aufgenommen" } ], "status": "final", "version": "9" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "Amazon Linux 2", "product": { "name": "Amazon Linux 2", "product_id": "398363", "product_identification_helper": { "cpe": "cpe:/o:amazon:linux_2:-" } } } ], "category": "vendor", "name": "Amazon" }, { "branches": [ { "category": "product_name", "name": "Gentoo Linux", "product": { "name": "Gentoo Linux", "product_id": "T012167", "product_identification_helper": { "cpe": "cpe:/o:gentoo:linux:-" } } } ], "category": "vendor", "name": "Gentoo" }, { "branches": [ { "category": "product_name", "name": "Open Source BusyBox", "product": { "name": "Open Source BusyBox", "product_id": "T013362", "product_identification_helper": { "cpe": "cpe:/a:busybox:busybox:-" } } } ], "category": "vendor", "name": "Open Source" }, { "branches": [ { "category": "product_name", "name": "SUSE Linux", "product": { "name": "SUSE Linux", "product_id": "T002207", "product_identification_helper": { "cpe": "cpe:/o:suse:suse_linux:-" } } } ], "category": "vendor", "name": "SUSE" }, { "branches": [ { "category": "product_name", "name": "Ubuntu Linux", "product": { "name": "Ubuntu Linux", "product_id": "T000126", "product_identification_helper": { "cpe": "cpe:/o:canonical:ubuntu_linux:-" } } } ], "category": "vendor", "name": "Ubuntu" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-42373", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein entfernter anonymer oder authentisierter Angreifer kann diese Schwachstellen ausnutzen, um Informationen offenzulegen und einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42373" }, { "cve": "CVE-2021-42374", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein entfernter anonymer oder authentisierter Angreifer kann diese Schwachstellen ausnutzen, um Informationen offenzulegen und einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42375", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein entfernter anonymer oder authentisierter Angreifer kann diese Schwachstellen ausnutzen, um Informationen offenzulegen und einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42376", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein entfernter anonymer oder authentisierter Angreifer kann diese Schwachstellen ausnutzen, um Informationen offenzulegen und einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42377", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42378", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "notes": [ { "category": "description", "text": "In BusyBox existieren mehrere Schwachstellen. Ein authentisierter Angreifer kann diese Schwachstellen ausnutzen, um einen Denial of Service Zustand zu verursachen oder beliebigen Code zur Ausf\u00fchrung zu bringen." } ], "product_status": { "known_affected": [ "T002207", "T000126", "398363", "T012167", "T013362" ] }, "release_date": "2021-11-09T23:00:00Z", "title": "CVE-2021-42386" } ] }
wid-sec-w-2023-1432
Vulnerability from csaf_certbund
Published
2023-06-12 22:00
Modified
2023-06-22 22:00
Summary
Siemens SIMATIC S7: Mehrere Schwachstellen
Notes
Das BSI ist als Anbieter für die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch dafür verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgfältig im Einzelfall zu prüfen.
Produktbeschreibung
Die SIMATIC S7 ist eine Serie von SPS (Speicherprogrammierbare Steuerungen) für Automatisierungsanwendungen.
Angriff
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien zu erweitern und Daten zu manipulieren.
Betroffene Betriebssysteme
- BIOS/Firmware
{ "document": { "aggregate_severity": { "text": "kritisch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "Die SIMATIC S7 ist eine Serie von SPS (Speicherprogrammierbare Steuerungen) f\u00fcr Automatisierungsanwendungen.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren.", "title": "Angriff" }, { "category": "general", "text": "- BIOS/Firmware", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-1432 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-1432.json" }, { "category": "self", "summary": "WID-SEC-2023-1432 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-1432" }, { "category": "external", "summary": "Ubuntu Security Notice USN-6187-1 vom 2023-06-22", "url": "https://ubuntu.com/security/notices/USN-6187-1" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-06-12", "url": "https://cert-portal.siemens.com/productcert/html/ssa-831302.html" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-06-12", "url": "https://cert-portal.siemens.com/productcert/html/ssa-794697.html" } ], "source_lang": "en-US", "title": "Siemens SIMATIC S7: Mehrere Schwachstellen", "tracking": { "current_release_date": "2023-06-22T22:00:00.000+00:00", "generator": { "date": "2024-02-15T17:30:48.504+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2023-1432", "initial_release_date": "2023-06-12T22:00:00.000+00:00", "revision_history": [ { "date": "2023-06-12T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" }, { "date": "2023-06-22T22:00:00.000+00:00", "number": "2", "summary": "Neue Updates von Ubuntu aufgenommen" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "Siemens SIMATIC S7 1500 TM MFP", "product": { "name": "Siemens SIMATIC S7 1500 TM MFP", "product_id": "T028071", "product_identification_helper": { "cpe": "cpe:/h:siemens:simatic_s7:1500_tm_mfp" } } } ], "category": "vendor", "name": "Siemens" }, { "branches": [ { "category": "product_name", "name": "Ubuntu Linux", "product": { "name": "Ubuntu Linux", "product_id": "T000126", "product_identification_helper": { "cpe": "cpe:/o:canonical:ubuntu_linux:-" } } } ], "category": "vendor", "name": "Ubuntu" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-26607", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-26607" }, { "cve": "CVE-2023-23559", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-23559" }, { "cve": "CVE-2023-23455", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-23455" }, { "cve": "CVE-2023-23454", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-23454" }, { "cve": "CVE-2023-1095", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-1095" }, { "cve": "CVE-2023-1077", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-1077" }, { "cve": "CVE-2023-1073", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-1073" }, { "cve": "CVE-2023-0590", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0590" }, { "cve": "CVE-2023-0466", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0466" }, { "cve": "CVE-2023-0465", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0465" }, { "cve": "CVE-2023-0464", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0464" }, { "cve": "CVE-2023-0394", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0394" }, { "cve": "CVE-2023-0286", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0286" }, { "cve": "CVE-2023-0215", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0215" }, { "cve": "CVE-2023-0179", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2023-0179" }, { "cve": "CVE-2022-47946", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-47946" }, { "cve": "CVE-2022-47929", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-47929" }, { "cve": "CVE-2022-47520", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-47520" }, { "cve": "CVE-2022-47518", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-47518" }, { "cve": "CVE-2022-4662", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4662" }, { "cve": "CVE-2022-4450", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4450" }, { "cve": "CVE-2022-4378", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4378" }, { "cve": "CVE-2022-43750", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-43750" }, { "cve": "CVE-2022-4304", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4304" }, { "cve": "CVE-2022-42896", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42896" }, { "cve": "CVE-2022-42895", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42895" }, { "cve": "CVE-2022-42722", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42722" }, { "cve": "CVE-2022-42721", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42721" }, { "cve": "CVE-2022-42720", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42720" }, { "cve": "CVE-2022-42719", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42719" }, { "cve": "CVE-2022-42703", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42703" }, { "cve": "CVE-2022-42432", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42432" }, { "cve": "CVE-2022-42329", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42329" }, { "cve": "CVE-2022-42328", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-42328" }, { "cve": "CVE-2022-41850", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-41850" }, { "cve": "CVE-2022-41849", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-41849" }, { "cve": "CVE-2022-41674", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-41674" }, { "cve": "CVE-2022-4139", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4139" }, { "cve": "CVE-2022-4129", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4129" }, { "cve": "CVE-2022-41222", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-41222" }, { "cve": "CVE-2022-41218", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-41218" }, { "cve": "CVE-2022-4095", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-4095" }, { "cve": "CVE-2022-40768", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-40768" }, { "cve": "CVE-2022-40307", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-40307" }, { "cve": "CVE-2022-39190", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-39190" }, { "cve": "CVE-2022-39188", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-39188" }, { "cve": "CVE-2022-36946", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-36946" }, { "cve": "CVE-2022-36879", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-36879" }, { "cve": "CVE-2022-3649", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3649" }, { "cve": "CVE-2022-3646", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3646" }, { "cve": "CVE-2022-3635", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3635" }, { "cve": "CVE-2022-3633", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3633" }, { "cve": "CVE-2022-3629", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3629" }, { "cve": "CVE-2022-36280", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-36280" }, { "cve": "CVE-2022-3628", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3628" }, { "cve": "CVE-2022-3625", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3625" }, { "cve": "CVE-2022-3621", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3621" }, { "cve": "CVE-2022-36123", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-36123" }, { "cve": "CVE-2022-3606", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3606" }, { "cve": "CVE-2022-3594", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3594" }, { "cve": "CVE-2022-3586", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3586" }, { "cve": "CVE-2022-3565", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3565" }, { "cve": "CVE-2022-3564", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3564" }, { "cve": "CVE-2022-3545", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3545" }, { "cve": "CVE-2022-3534", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3534" }, { "cve": "CVE-2022-3524", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3524" }, { "cve": "CVE-2022-3521", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3521" }, { "cve": "CVE-2022-34918", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-34918" }, { "cve": "CVE-2022-3435", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3435" }, { "cve": "CVE-2022-3303", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3303" }, { "cve": "CVE-2022-32296", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-32296" }, { "cve": "CVE-2022-32250", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-32250" }, { "cve": "CVE-2022-3169", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3169" }, { "cve": "CVE-2022-3115", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3115" }, { "cve": "CVE-2022-3104", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3104" }, { "cve": "CVE-2022-3028", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-3028" }, { "cve": "CVE-2022-30065", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-30065" }, { "cve": "CVE-2022-2978", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2978" }, { "cve": "CVE-2022-2959", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2959" }, { "cve": "CVE-2022-2905", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2905" }, { "cve": "CVE-2022-28391", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-28391" }, { "cve": "CVE-2022-2663", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2663" }, { "cve": "CVE-2022-26373", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-26373" }, { "cve": "CVE-2022-2602", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2602" }, { "cve": "CVE-2022-2588", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2588" }, { "cve": "CVE-2022-2586", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2586" }, { "cve": "CVE-2022-2585", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2585" }, { "cve": "CVE-2022-2503", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2503" }, { "cve": "CVE-2022-2327", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2327" }, { "cve": "CVE-2022-23219", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-23219" }, { "cve": "CVE-2022-23218", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-23218" }, { "cve": "CVE-2022-2274", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2274" }, { "cve": "CVE-2022-2153", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2153" }, { "cve": "CVE-2022-21505", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-21505" }, { "cve": "CVE-2022-21233", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-21233" }, { "cve": "CVE-2022-21166", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-21166" }, { "cve": "CVE-2022-21125", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-21125" }, { "cve": "CVE-2022-21123", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-21123" }, { "cve": "CVE-2022-2097", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2097" }, { "cve": "CVE-2022-2078", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2078" }, { "cve": "CVE-2022-2068", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-2068" }, { "cve": "CVE-2022-20572", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-20572" }, { "cve": "CVE-2022-20566", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-20566" }, { "cve": "CVE-2022-20422", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-20422" }, { "cve": "CVE-2022-20421", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-20421" }, { "cve": "CVE-2022-1882", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1882" }, { "cve": "CVE-2022-1852", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1852" }, { "cve": "CVE-2022-1679", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1679" }, { "cve": "CVE-2022-1473", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1473" }, { "cve": "CVE-2022-1462", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1462" }, { "cve": "CVE-2022-1434", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1434" }, { "cve": "CVE-2022-1343", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1343" }, { "cve": "CVE-2022-1292", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1292" }, { "cve": "CVE-2022-1184", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1184" }, { "cve": "CVE-2022-1012", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-1012" }, { "cve": "CVE-2022-0171", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2022-0171" }, { "cve": "CVE-2021-42386", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42386" }, { "cve": "CVE-2021-42385", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42384", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42383", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42382", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42381", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42380", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42379", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42378", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42377", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42376", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42375", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42374", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42373", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-42373" }, { "cve": "CVE-2021-4037", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-4037" }, { "cve": "CVE-2021-3999", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-3999" }, { "cve": "CVE-2021-3998", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-3998" }, { "cve": "CVE-2021-38604", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-38604" }, { "cve": "CVE-2021-3759", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-3759" }, { "cve": "CVE-2021-35942", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-35942" }, { "cve": "CVE-2021-33655", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-33655" }, { "cve": "CVE-2021-33574", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-33574" }, { "cve": "CVE-2021-3326", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-3326" }, { "cve": "CVE-2021-28831", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-28831" }, { "cve": "CVE-2021-27645", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-27645" }, { "cve": "CVE-2021-20269", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2021-20269" }, { "cve": "CVE-2020-29562", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2020-29562" }, { "cve": "CVE-2020-27618", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2020-27618" }, { "cve": "CVE-2020-1752", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2020-1752" }, { "cve": "CVE-2020-10029", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2020-10029" }, { "cve": "CVE-2019-25013", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2019-25013" }, { "cve": "CVE-2018-13405", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2018-13405" }, { "cve": "CVE-2016-10228", "notes": [ { "category": "description", "text": "In Siemens SIMATIC S7 existieren mehrere Schwachstellen. Die Fehler bestehen unter anderem aufgrund von unzul\u00e4ssigen Einschr\u00e4nkungen, Puffer\u00fcberl\u00e4ufen, fehlenden Freigaben und use-after-free-Problemen. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuf\u00fchren, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T000126", "T028071" ] }, "release_date": "2023-06-12T22:00:00Z", "title": "CVE-2016-10228" } ] }
SSA-831302
Vulnerability from csaf_siemens
Published
2023-06-13 00:00
Modified
2024-04-09 00:00
Summary
SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0
Notes
Summary
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0.
Siemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0.\n\nSiemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-831302.html" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-831302.json" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-831302.pdf" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-831302.txt" } ], "title": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0", "tracking": { "current_release_date": "2024-04-09T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-831302", "initial_release_date": "2023-06-13T00:00:00Z", "revision_history": [ { "date": "2023-06-13T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2023-09-12T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added CVE-2022-1015, CVE-2023-2898, CVE-2023-31248, CVE-2023-3390, CVE-2023-35001, CVE-2023-3610, CVE-2023-3611, CVE-2023-3776, CVE-2023-4004, CVE-2023-4015, CVE-2023-4128, CVE-2023-4147, CVE-2023-4273" }, { "date": "2023-11-14T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added CVE-2023-4527, CVE-2023-4806, CVE-2023-4911, CVE-2023-5156" }, { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.3", "number": "4", "summary": "Added CVE-2021-44879, CVE-2023-45863" }, { "date": "2024-04-09T00:00:00Z", "legacy_version": "1.4", "number": "5", "summary": "Added fix for SIMATIC S7-1500 TM MFP - BIOS" } ], "status": "interim", "version": "5" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1.3.0", "product": { "name": "SIMATIC S7-1500 TM MFP - BIOS", "product_id": "1" } } ], "category": "product_name", "name": "SIMATIC S7-1500 TM MFP - BIOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-10228", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The iconv program in the GNU C Library (aka glibc or libc6) 2.31 and earlier, when invoked with multiple suffixes in the destination encoding (TRANSLATE or IGNORE) along with the -c option, enters an infinite loop when processing invalid multi-byte input sequences, leading to a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2016-10228" }, { "cve": "CVE-2019-25013", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The iconv feature in the GNU C Library (aka glibc or libc6) through 2.32, when processing invalid multi-byte input sequences in the EUC-KR encoding, may have a buffer over-read.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2019-25013" }, { "cve": "CVE-2020-1752", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability introduced in glibc upstream version 2.14 was found in the way the tilde expansion was carried out. Directory paths containing an initial tilde followed by a valid username were affected by this issue. A local attacker could exploit this flaw by creating a specially crafted path that, when processed by the glob function, would potentially lead to arbitrary code execution. This was fixed in version 2.32.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-1752" }, { "cve": "CVE-2020-10029", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The GNU C Library (aka glibc or libc6) before 2.32 could overflow an on-stack buffer during range reduction if an input to an 80-bit long double function contains a non-canonical bit pattern, a seen when passing a 0x5d414141414141410000 value to sinl on x86 targets. This is related to sysdeps/ieee754/ldbl-96/e_rem_pio2l.c.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-10029" }, { "cve": "CVE-2020-27618", "cwe": { "id": "CWE-835", "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.32 and earlier, when processing invalid multi-byte input sequences in IBM1364, IBM1371, IBM1388, IBM1390, and IBM1399 encodings, fails to advance the input state, which could lead to an infinite loop in applications, resulting in a denial of service, a different vulnerability from CVE-2016-10228.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-27618" }, { "cve": "CVE-2020-29562", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.30 to 2.32, when converting UCS4 text containing an irreversible character, fails an assertion in the code path and aborts the program, potentially resulting in a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-29562" }, { "cve": "CVE-2021-3326", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.32 and earlier, when processing invalid input sequences in the ISO-2022-JP-3 encoding, fails an assertion in the code path and aborts the program, potentially resulting in a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3326" }, { "cve": "CVE-2021-3998", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. The realpath() function can mistakenly return an unexpected value, potentially leading to information leakage and disclosure of sensitive data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3998" }, { "cve": "CVE-2021-3999", "cwe": { "id": "CWE-193", "name": "Off-by-one Error" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. An off-by-one buffer overflow and underflow in getcwd() may lead to memory corruption when the size of the buffer is exactly 1. A local attacker who can control the input buffer and size passed to getcwd() in a setuid program could use this flaw to potentially execute arbitrary code and escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3999" }, { "cve": "CVE-2021-20269", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "A flaw was found in the permissions of a log file created by kexec-tools. This flaw allows a local unprivileged user to read this file and leak kernel internal information from a previous panic. The highest threat from this vulnerability is to confidentiality. This flaw affects kexec-tools shipped by Fedora versions prior to 2.0.21-8 and RHEL versions prior to 2.0.20-47.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-20269" }, { "cve": "CVE-2021-27645", "cwe": { "id": "CWE-415", "name": "Double Free" }, "notes": [ { "category": "summary", "text": "The nameserver caching daemon (nscd) in the GNU C Library (aka glibc or libc6) 2.29 through 2.33, when processing a request for netgroup lookup, may crash due to a double-free, potentially resulting in degraded service or Denial of Service on the local system. This is related to netgroupcache.c.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.5, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-27645" }, { "cve": "CVE-2021-28831", "cwe": { "id": "CWE-755", "name": "Improper Handling of Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "decompress_gunzip.c in BusyBox through 1.32.1 mishandles the error bit on the huft_build result pointer, with a resultant invalid free or segmentation fault, via malformed gzip data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-28831" }, { "cve": "CVE-2021-33574", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The mq_notify function in the GNU C Library (aka glibc) versions 2.32 and 2.33 has a use-after-free. It may use the notification thread attributes object (passed through its struct sigevent parameter) after it has been freed by the caller, leading to a denial of service (application crash) or possibly unspecified other impact.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-33574" }, { "cve": "CVE-2021-35942", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "The wordexp function in the GNU C Library (aka glibc) through 2.33 may crash or read arbitrary memory in parse_param (in posix/wordexp.c) when called with an untrusted, crafted pattern, potentially resulting in a denial of service or disclosure of information. This occurs because atoi was used but strtoul should have been used to ensure correct calculations.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-35942" }, { "cve": "CVE-2021-38604", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "In librt in the GNU C Library (aka glibc) through 2.34, sysdeps/unix/sysv/linux/mq_notify.c mishandles certain NOTIFY_REMOVED data, leading to a NULL pointer dereference. NOTE: this vulnerability was introduced as a side effect of the CVE-2021-33574 fix.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-38604" }, { "cve": "CVE-2021-42373", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s man applet leads to denial of service when a section name is supplied but no page argument is given.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42373" }, { "cve": "CVE-2021-42374", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42375", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An incorrect handling of a special element in Busybox\u0027s ash applet leads to denial of service when processing a crafted shell command, due to the shell mistaking specific characters for reserved characters. This may be used for DoS under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42376", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s hush applet leads to denial of service when processing a crafted shell command, due to missing validation after a \\x03 delimiter character. This may be used for DoS under very rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42377", "cwe": { "id": "CWE-763", "name": "Release of Invalid Pointer or Reference" }, "notes": [ { "category": "summary", "text": "An attacker-controlled pointer free in Busybox\u0027s hush applet leads to denial of service and possible code execution when processing a crafted shell command, due to the shell mishandling the \u0026\u0026\u0026 string. This may be used for remote code execution under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42378", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42386" }, { "cve": "CVE-2021-44879", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "In gc_data_segment in fs/f2fs/gc.c in the Linux kernel before 5.16.3, special files are not considered, leading to a move_data_page NULL pointer dereference.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-44879" }, { "cve": "CVE-2022-1015", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel in linux/net/netfilter/nf_tables_api.c of the netfilter subsystem. This flaw allows a local user to cause an out-of-bounds write issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-1015" }, { "cve": "CVE-2022-1882", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u2019s pipes functionality in how a user performs manipulations with the pipe post_one_notification() after free_pipe_info() that is already called. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-1882" }, { "cve": "CVE-2022-2585", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u2019s POSIX CPU timers functionality in the way a user creates and then deletes the timer in the non-leader thread of the program. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2585" }, { "cve": "CVE-2022-2588", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Zhenpeng Lin discovered that the network packet scheduler implementation in the Linux kernel did not properly remove all references to a route filter before freeing it in some situations. A local attacker could use this to cause a denial of service (system crash) or execute arbitrary code.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2588" }, { "cve": "CVE-2022-2905", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds memory read flaw was found in the Linux kernel\u0027s BPF subsystem in how a user calls the bpf_tail_call function with a key larger than the max_entries of the map. This flaw allows a local user to gain unauthorized access to data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2905" }, { "cve": "CVE-2022-3028", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "A race condition was found in the Linux kernel\u0027s IP framework for transforming packets (XFRM subsystem) when multiple calls to xfrm_probe_algs occurred simultaneously. This flaw could allow a local attacker to potentially trigger an out-of-bounds write or leak kernel heap memory by performing an out-of-bounds read and copying it into a socket.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3028" }, { "cve": "CVE-2022-3435", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "A vulnerability classified as problematic has been found in Linux Kernel. This affects the function fib_nh_match of the file net/ipv4/fib_semantics.c of the component IPv4 Handler. The manipulation leads to out-of-bounds read. It is possible to initiate the attack remotely. It is recommended to apply a patch to fix this issue. The identifier VDB-210357 was assigned to this vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3435" }, { "cve": "CVE-2022-3586", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel\u2019s networking code. A use-after-free was found in the way the sch_sfb enqueue function used the socket buffer (SKB) cb field after the same SKB had been enqueued (and freed) into a child qdisc. This flaw allows a local, unprivileged user to crash the system, causing a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3586" }, { "cve": "CVE-2022-4378", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A stack overflow flaw was found in the Linux kernel\u0027s SYSCTL subsystem in how a user changes certain kernel parameters and variables. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-4378" }, { "cve": "CVE-2022-4662", "cwe": { "id": "CWE-455", "name": "Non-exit on Failed Initialization" }, "notes": [ { "category": "summary", "text": "A flaw incorrect access control in the Linux kernel USB core subsystem was found in the way user attaches usb device. A local user could use this flaw to crash the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-4662" }, { "cve": "CVE-2022-20421", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "In binder_inc_ref_for_node of binder.c, there is a possible way to corrupt memory due to a use after free. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-239630375References: Upstream kernel", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-20421" }, { "cve": "CVE-2022-20422", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "In emulation_proc_handler of armv8_deprecated.c, there is a possible way to corrupt memory due to a race condition. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-237540956References: Upstream kernel", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-20422" }, { "cve": "CVE-2022-21233", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "Improper isolation of shared resources in some Intel(R) Processors may allow a privileged user to potentially enable information disclosure via local access.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-21233" }, { "cve": "CVE-2022-23218", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The deprecated compatibility function svcunix_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its path argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-23218" }, { "cve": "CVE-2022-23219", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The deprecated compatibility function clnt_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its hostname argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-23219" }, { "cve": "CVE-2022-28391", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "BusyBox through 1.35.0 allows remote attackers to execute arbitrary code if netstat is used to print a DNS PTR record\u0027s value to a VT compatible terminal. Alternatively, the attacker could choose to change the terminal\u0027s colors.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-28391" }, { "cve": "CVE-2022-30065", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox 1.35-x\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-30065" }, { "cve": "CVE-2022-39188", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "An issue was discovered in include/asm-generic/tlb.h in the Linux kernel before 5.19. Because of a race condition (unmap_mapping_range versus munmap), a device driver can free a page while it still has stale TLB entries. This only occurs in situations with VM_PFNMAP VMAs.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-39188" }, { "cve": "CVE-2022-39190", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "An issue was discovered in net/netfilter/nf_tables_api.c in the Linux kernel before 5.19.6. A denial of service can occur upon binding to an already bound chain.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-39190" }, { "cve": "CVE-2022-40307", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "An issue was discovered in the Linux kernel through 5.19.8. drivers/firmware/efi/capsule-loader.c has a race condition with a resultant use-after-free.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-40307" }, { "cve": "CVE-2022-41222", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "mm/mremap.c in the Linux kernel before 5.13.3 has a use-after-free via a stale TLB because an rmap lock is not held during a PUD move.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-41222" }, { "cve": "CVE-2022-42703", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "mm/rmap.c in the Linux kernel before 5.19.7 has a use-after-free related to leaf anon_vma double reuse.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-42703" }, { "cve": "CVE-2023-0179", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability was found in the Netfilter subsystem in the Linux Kernel. This issue could allow the leakage of both stack and heap addresses, and potentially allow Local Privilege Escalation to the root user via arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0179" }, { "cve": "CVE-2023-0394", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference flaw was found in rawv6_push_pending_frames in net/ipv6/raw.c in the network subcomponent in the Linux kernel. This flaw causes the system to crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0394" }, { "cve": "CVE-2023-1073", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A memory corruption flaw was found in the Linux kernel\u2019s human interface device (HID) subsystem in how a user inserts a malicious USB device. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-1073" }, { "cve": "CVE-2023-2898", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "There is a null-pointer-dereference flaw found in f2fs_write_end_io in fs/f2fs/data.c in the Linux kernel. This flaw allows a local privileged user to cause a denial of service problem.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-2898" }, { "cve": "CVE-2023-3390", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability was found in the Linux kernel\u0027s netfilter subsystem in net/netfilter/nf_tables_api.c.\n\nMishandled error handling with NFT_MSG_NEWRULE makes it possible to use a dangling pointer in the same transaction causing a use-after-free vulnerability. This flaw allows a local attacker with user access to cause a privilege escalation issue.\n\nWe recommend upgrading past commit\u00a01240eb93f0616b21c675416516ff3d74798fdc97.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-3390" }, { "cve": "CVE-2023-3610", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability in the Linux kernel\u0027s netfilter: nf_tables component can be exploited to achieve local privilege escalation.\r\n\r\nFlaw in the error handling of bound chains causes a use-after-free in the abort path of NFT_MSG_NEWRULE. The vulnerability requires CAP_NET_ADMIN to be triggered.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-3610" }, { "cve": "CVE-2023-3611", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write vulnerability in the Linux kernel\u0027s net/sched: sch_qfq component can be exploited to achieve local privilege escalation.\r\n\r\nThe qfq_change_agg() function in net/sched/sch_qfq.c allows an out-of-bounds write because lmax is updated according to packet sizes without bounds checks.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-3611" }, { "cve": "CVE-2023-3776", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\r\n\r\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-3776" }, { "cve": "CVE-2023-4004", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u0027s netfilter in the way a user triggers the nft_pipapo_remove function with the element, without a NFT_SET_EXT_KEY_END. This issue could allow a local user to crash the system or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4004" }, { "cve": "CVE-2023-4015", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The netfilter subsystem in the Linux kernel did not properly handle bound chain deactivation in certain circumstances. A local attacker could possibly use this to cause a denial of service (system crash) or execute arbitrary code.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4015" }, { "cve": "CVE-2023-4128", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability in net/sched/cls_fw.c in classifiers (cls_fw, cls_u32, and cls_route) in the Linux Kernel allows a local attacker to perform a local privilege escalation due to incorrect handling of the existing filter, leading to a kernel information leak.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4128" }, { "cve": "CVE-2023-4147", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability in the Linux kernel\u2019s Netfilter functionality when adding a rule with NFTA_RULE_CHAIN_ID allows a local user to crash or escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4147" }, { "cve": "CVE-2023-4273", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "This vulnerability exists in the implementation of the file name reconstruction function, which is responsible for reading file name entries from a directory index and merging file name parts belonging to one file into a single long file name. Since the file name characters are copied into a stack variable, a local privileged attacker could use this vulnerability to overflow the kernel stack.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4273" }, { "cve": "CVE-2023-4527", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. When the getaddrinfo function is called with the AF_UNSPEC address family and the system is configured with no-aaaa mode via /etc/resolv.conf, a DNS response via TCP larger than 2048 bytes can potentially disclose stack contents through the function returned address data, and may cause a crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4527" }, { "cve": "CVE-2023-4806", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. In an extremely rare situation, the getaddrinfo function may access memory that has been freed, resulting in an application crash. This issue is only exploitable when a NSS module implements only the _nss_*_gethostbyname2_r and _nss_*_getcanonname_r hooks without implementing the _nss_*_gethostbyname3_r hook. The resolved name should return a large number of IPv6 and IPv4, and the call to the getaddrinfo function should have the AF_INET6 address family with AI_CANONNAME, AI_ALL and AI_V4MAPPED as flags.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4806" }, { "cve": "CVE-2023-4911", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A buffer overflow was discovered in the GNU C Library\u0027s dynamic loader ld.so while processing the GLIBC_TUNABLES environment variable. This issue could allow a local attacker to use maliciously crafted GLIBC_TUNABLES environment variables when launching binaries with SUID permission to execute code with elevated privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4911" }, { "cve": "CVE-2023-5156", "cwe": { "id": "CWE-401", "name": "Missing Release of Memory after Effective Lifetime" }, "notes": [ { "category": "summary", "text": "A flaw was found in the GNU C Library. A recent fix for CVE-2023-4806 introduced the potential for a memory leak, which may result in an application crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-5156" }, { "cve": "CVE-2023-31248", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Linux Kernel nftables Use-After-Free Local Privilege Escalation Vulnerability; `nft_chain_lookup_byid()` failed to check whether a chain was active and CAP_NET_ADMIN is in any user or network namespace", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-31248" }, { "cve": "CVE-2023-35001", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Linux Kernel nftables Out-Of-Bounds Read/Write Vulnerability; nft_byteorder poorly handled vm register contents when CAP_NET_ADMIN is in any user or network namespace", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-35001" }, { "cve": "CVE-2023-45863", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An issue was discovered in lib/kobject.c in the Linux kernel before 6.2.3. With root access, an attacker can trigger a race condition that results in a fill_kobj_path out-of-bounds write.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-45863" } ] }
ssa-831302
Vulnerability from csaf_siemens
Published
2023-06-13 00:00
Modified
2024-04-09 00:00
Summary
SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0
Notes
Summary
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0.
Siemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0.\n\nSiemens has released a new version for SIMATIC S7-1500 TM MFP - BIOS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-831302.html" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-831302.json" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-831302.pdf" }, { "category": "self", "summary": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-831302.txt" } ], "title": "SSA-831302: Vulnerabilities in the BIOS of the SIMATIC S7-1500 TM MFP before V1.3.0", "tracking": { "current_release_date": "2024-04-09T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-831302", "initial_release_date": "2023-06-13T00:00:00Z", "revision_history": [ { "date": "2023-06-13T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2023-09-12T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added CVE-2022-1015, CVE-2023-2898, CVE-2023-31248, CVE-2023-3390, CVE-2023-35001, CVE-2023-3610, CVE-2023-3611, CVE-2023-3776, CVE-2023-4004, CVE-2023-4015, CVE-2023-4128, CVE-2023-4147, CVE-2023-4273" }, { "date": "2023-11-14T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added CVE-2023-4527, CVE-2023-4806, CVE-2023-4911, CVE-2023-5156" }, { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.3", "number": "4", "summary": "Added CVE-2021-44879, CVE-2023-45863" }, { "date": "2024-04-09T00:00:00Z", "legacy_version": "1.4", "number": "5", "summary": "Added fix for SIMATIC S7-1500 TM MFP - BIOS" } ], "status": "interim", "version": "5" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1.3.0", "product": { "name": "SIMATIC S7-1500 TM MFP - BIOS", "product_id": "1" } } ], "category": "product_name", "name": "SIMATIC S7-1500 TM MFP - BIOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-10228", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The iconv program in the GNU C Library (aka glibc or libc6) 2.31 and earlier, when invoked with multiple suffixes in the destination encoding (TRANSLATE or IGNORE) along with the -c option, enters an infinite loop when processing invalid multi-byte input sequences, leading to a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2016-10228" }, { "cve": "CVE-2019-25013", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The iconv feature in the GNU C Library (aka glibc or libc6) through 2.32, when processing invalid multi-byte input sequences in the EUC-KR encoding, may have a buffer over-read.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2019-25013" }, { "cve": "CVE-2020-1752", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability introduced in glibc upstream version 2.14 was found in the way the tilde expansion was carried out. Directory paths containing an initial tilde followed by a valid username were affected by this issue. A local attacker could exploit this flaw by creating a specially crafted path that, when processed by the glob function, would potentially lead to arbitrary code execution. This was fixed in version 2.32.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-1752" }, { "cve": "CVE-2020-10029", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The GNU C Library (aka glibc or libc6) before 2.32 could overflow an on-stack buffer during range reduction if an input to an 80-bit long double function contains a non-canonical bit pattern, a seen when passing a 0x5d414141414141410000 value to sinl on x86 targets. This is related to sysdeps/ieee754/ldbl-96/e_rem_pio2l.c.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-10029" }, { "cve": "CVE-2020-27618", "cwe": { "id": "CWE-835", "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.32 and earlier, when processing invalid multi-byte input sequences in IBM1364, IBM1371, IBM1388, IBM1390, and IBM1399 encodings, fails to advance the input state, which could lead to an infinite loop in applications, resulting in a denial of service, a different vulnerability from CVE-2016-10228.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-27618" }, { "cve": "CVE-2020-29562", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.30 to 2.32, when converting UCS4 text containing an irreversible character, fails an assertion in the code path and aborts the program, potentially resulting in a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2020-29562" }, { "cve": "CVE-2021-3326", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "The iconv function in the GNU C Library (aka glibc or libc6) 2.32 and earlier, when processing invalid input sequences in the ISO-2022-JP-3 encoding, fails an assertion in the code path and aborts the program, potentially resulting in a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3326" }, { "cve": "CVE-2021-3998", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. The realpath() function can mistakenly return an unexpected value, potentially leading to information leakage and disclosure of sensitive data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3998" }, { "cve": "CVE-2021-3999", "cwe": { "id": "CWE-193", "name": "Off-by-one Error" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. An off-by-one buffer overflow and underflow in getcwd() may lead to memory corruption when the size of the buffer is exactly 1. A local attacker who can control the input buffer and size passed to getcwd() in a setuid program could use this flaw to potentially execute arbitrary code and escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-3999" }, { "cve": "CVE-2021-20269", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "A flaw was found in the permissions of a log file created by kexec-tools. This flaw allows a local unprivileged user to read this file and leak kernel internal information from a previous panic. The highest threat from this vulnerability is to confidentiality. This flaw affects kexec-tools shipped by Fedora versions prior to 2.0.21-8 and RHEL versions prior to 2.0.20-47.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-20269" }, { "cve": "CVE-2021-27645", "cwe": { "id": "CWE-415", "name": "Double Free" }, "notes": [ { "category": "summary", "text": "The nameserver caching daemon (nscd) in the GNU C Library (aka glibc or libc6) 2.29 through 2.33, when processing a request for netgroup lookup, may crash due to a double-free, potentially resulting in degraded service or Denial of Service on the local system. This is related to netgroupcache.c.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.5, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-27645" }, { "cve": "CVE-2021-28831", "cwe": { "id": "CWE-755", "name": "Improper Handling of Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "decompress_gunzip.c in BusyBox through 1.32.1 mishandles the error bit on the huft_build result pointer, with a resultant invalid free or segmentation fault, via malformed gzip data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-28831" }, { "cve": "CVE-2021-33574", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The mq_notify function in the GNU C Library (aka glibc) versions 2.32 and 2.33 has a use-after-free. It may use the notification thread attributes object (passed through its struct sigevent parameter) after it has been freed by the caller, leading to a denial of service (application crash) or possibly unspecified other impact.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-33574" }, { "cve": "CVE-2021-35942", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "The wordexp function in the GNU C Library (aka glibc) through 2.33 may crash or read arbitrary memory in parse_param (in posix/wordexp.c) when called with an untrusted, crafted pattern, potentially resulting in a denial of service or disclosure of information. This occurs because atoi was used but strtoul should have been used to ensure correct calculations.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-35942" }, { "cve": "CVE-2021-38604", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "In librt in the GNU C Library (aka glibc) through 2.34, sysdeps/unix/sysv/linux/mq_notify.c mishandles certain NOTIFY_REMOVED data, leading to a NULL pointer dereference. NOTE: this vulnerability was introduced as a side effect of the CVE-2021-33574 fix.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-38604" }, { "cve": "CVE-2021-42373", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s man applet leads to denial of service when a section name is supplied but no page argument is given.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42373" }, { "cve": "CVE-2021-42374", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds heap read in Busybox\u0027s unlzma applet leads to information leak and denial of service when crafted LZMA-compressed input is decompressed. This can be triggered by any applet/format that internally supports LZMA compression.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42374" }, { "cve": "CVE-2021-42375", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An incorrect handling of a special element in Busybox\u0027s ash applet leads to denial of service when processing a crafted shell command, due to the shell mistaking specific characters for reserved characters. This may be used for DoS under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42375" }, { "cve": "CVE-2021-42376", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference in Busybox\u0027s hush applet leads to denial of service when processing a crafted shell command, due to missing validation after a \\x03 delimiter character. This may be used for DoS under very rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42376" }, { "cve": "CVE-2021-42377", "cwe": { "id": "CWE-763", "name": "Release of Invalid Pointer or Reference" }, "notes": [ { "category": "summary", "text": "An attacker-controlled pointer free in Busybox\u0027s hush applet leads to denial of service and possible code execution when processing a crafted shell command, due to the shell mishandling the \u0026\u0026\u0026 string. This may be used for remote code execution under rare conditions of filtered command input.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42377" }, { "cve": "CVE-2021-42378", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_i function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42378" }, { "cve": "CVE-2021-42379", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the next_input_file function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42379" }, { "cve": "CVE-2021-42380", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the clrvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42380" }, { "cve": "CVE-2021-42381", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the hash_init function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42381" }, { "cve": "CVE-2021-42382", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the getvar_s function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42382" }, { "cve": "CVE-2021-42383", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42383" }, { "cve": "CVE-2021-42384", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the handle_special function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42384" }, { "cve": "CVE-2021-42385", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42385" }, { "cve": "CVE-2021-42386", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in awk leads to denial of service and possibly code execution when processing a crafted awk pattern in the nvalloc function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-42386" }, { "cve": "CVE-2021-44879", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "In gc_data_segment in fs/f2fs/gc.c in the Linux kernel before 5.16.3, special files are not considered, leading to a move_data_page NULL pointer dereference.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2021-44879" }, { "cve": "CVE-2022-1015", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel in linux/net/netfilter/nf_tables_api.c of the netfilter subsystem. This flaw allows a local user to cause an out-of-bounds write issue.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-1015" }, { "cve": "CVE-2022-1882", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u2019s pipes functionality in how a user performs manipulations with the pipe post_one_notification() after free_pipe_info() that is already called. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-1882" }, { "cve": "CVE-2022-2585", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u2019s POSIX CPU timers functionality in the way a user creates and then deletes the timer in the non-leader thread of the program. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2585" }, { "cve": "CVE-2022-2588", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Zhenpeng Lin discovered that the network packet scheduler implementation in the Linux kernel did not properly remove all references to a route filter before freeing it in some situations. A local attacker could use this to cause a denial of service (system crash) or execute arbitrary code.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2588" }, { "cve": "CVE-2022-2905", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds memory read flaw was found in the Linux kernel\u0027s BPF subsystem in how a user calls the bpf_tail_call function with a key larger than the max_entries of the map. This flaw allows a local user to gain unauthorized access to data.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-2905" }, { "cve": "CVE-2022-3028", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "A race condition was found in the Linux kernel\u0027s IP framework for transforming packets (XFRM subsystem) when multiple calls to xfrm_probe_algs occurred simultaneously. This flaw could allow a local attacker to potentially trigger an out-of-bounds write or leak kernel heap memory by performing an out-of-bounds read and copying it into a socket.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3028" }, { "cve": "CVE-2022-3435", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "A vulnerability classified as problematic has been found in Linux Kernel. This affects the function fib_nh_match of the file net/ipv4/fib_semantics.c of the component IPv4 Handler. The manipulation leads to out-of-bounds read. It is possible to initiate the attack remotely. It is recommended to apply a patch to fix this issue. The identifier VDB-210357 was assigned to this vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3435" }, { "cve": "CVE-2022-3586", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in the Linux kernel\u2019s networking code. A use-after-free was found in the way the sch_sfb enqueue function used the socket buffer (SKB) cb field after the same SKB had been enqueued (and freed) into a child qdisc. This flaw allows a local, unprivileged user to crash the system, causing a denial of service.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-3586" }, { "cve": "CVE-2022-4378", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A stack overflow flaw was found in the Linux kernel\u0027s SYSCTL subsystem in how a user changes certain kernel parameters and variables. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-4378" }, { "cve": "CVE-2022-4662", "cwe": { "id": "CWE-455", "name": "Non-exit on Failed Initialization" }, "notes": [ { "category": "summary", "text": "A flaw incorrect access control in the Linux kernel USB core subsystem was found in the way user attaches usb device. A local user could use this flaw to crash the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-4662" }, { "cve": "CVE-2022-20421", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "In binder_inc_ref_for_node of binder.c, there is a possible way to corrupt memory due to a use after free. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-239630375References: Upstream kernel", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-20421" }, { "cve": "CVE-2022-20422", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "In emulation_proc_handler of armv8_deprecated.c, there is a possible way to corrupt memory due to a race condition. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android kernelAndroid ID: A-237540956References: Upstream kernel", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-20422" }, { "cve": "CVE-2022-21233", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "Improper isolation of shared resources in some Intel(R) Processors may allow a privileged user to potentially enable information disclosure via local access.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-21233" }, { "cve": "CVE-2022-23218", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The deprecated compatibility function svcunix_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its path argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-23218" }, { "cve": "CVE-2022-23219", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The deprecated compatibility function clnt_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its hostname argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-23219" }, { "cve": "CVE-2022-28391", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "BusyBox through 1.35.0 allows remote attackers to execute arbitrary code if netstat is used to print a DNS PTR record\u0027s value to a VT compatible terminal. Alternatively, the attacker could choose to change the terminal\u0027s colors.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-28391" }, { "cve": "CVE-2022-30065", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free in Busybox 1.35-x\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-30065" }, { "cve": "CVE-2022-39188", "cwe": { "id": "CWE-362", "name": "Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)" }, "notes": [ { "category": "summary", "text": "An issue was discovered in include/asm-generic/tlb.h in the Linux kernel before 5.19. Because of a race condition (unmap_mapping_range versus munmap), a device driver can free a page while it still has stale TLB entries. This only occurs in situations with VM_PFNMAP VMAs.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-39188" }, { "cve": "CVE-2022-39190", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "An issue was discovered in net/netfilter/nf_tables_api.c in the Linux kernel before 5.19.6. A denial of service can occur upon binding to an already bound chain.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-39190" }, { "cve": "CVE-2022-40307", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "An issue was discovered in the Linux kernel through 5.19.8. drivers/firmware/efi/capsule-loader.c has a race condition with a resultant use-after-free.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-40307" }, { "cve": "CVE-2022-41222", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "mm/mremap.c in the Linux kernel before 5.13.3 has a use-after-free via a stale TLB because an rmap lock is not held during a PUD move.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-41222" }, { "cve": "CVE-2022-42703", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "mm/rmap.c in the Linux kernel before 5.19.7 has a use-after-free related to leaf anon_vma double reuse.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2022-42703" }, { "cve": "CVE-2023-0179", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability was found in the Netfilter subsystem in the Linux Kernel. This issue could allow the leakage of both stack and heap addresses, and potentially allow Local Privilege Escalation to the root user via arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0179" }, { "cve": "CVE-2023-0394", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "A NULL pointer dereference flaw was found in rawv6_push_pending_frames in net/ipv6/raw.c in the network subcomponent in the Linux kernel. This flaw causes the system to crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-0394" }, { "cve": "CVE-2023-1073", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "A memory corruption flaw was found in the Linux kernel\u2019s human interface device (HID) subsystem in how a user inserts a malicious USB device. This flaw allows a local user to crash or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-1073" }, { "cve": "CVE-2023-2898", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "There is a null-pointer-dereference flaw found in f2fs_write_end_io in fs/f2fs/data.c in the Linux kernel. This flaw allows a local privileged user to cause a denial of service problem.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-2898" }, { "cve": "CVE-2023-3390", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability was found in the Linux kernel\u0027s netfilter subsystem in net/netfilter/nf_tables_api.c.\n\nMishandled error handling with NFT_MSG_NEWRULE makes it possible to use a dangling pointer in the same transaction causing a use-after-free vulnerability. This flaw allows a local attacker with user access to cause a privilege escalation issue.\n\nWe recommend upgrading past commit\u00a01240eb93f0616b21c675416516ff3d74798fdc97.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-3390" }, { "cve": "CVE-2023-3610", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability in the Linux kernel\u0027s netfilter: nf_tables component can be exploited to achieve local privilege escalation.\r\n\r\nFlaw in the error handling of bound chains causes a use-after-free in the abort path of NFT_MSG_NEWRULE. The vulnerability requires CAP_NET_ADMIN to be triggered.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-3610" }, { "cve": "CVE-2023-3611", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write vulnerability in the Linux kernel\u0027s net/sched: sch_qfq component can be exploited to achieve local privilege escalation.\r\n\r\nThe qfq_change_agg() function in net/sched/sch_qfq.c allows an out-of-bounds write because lmax is updated according to packet sizes without bounds checks.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-3611" }, { "cve": "CVE-2023-3776", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability in the Linux kernel\u0027s net/sched: cls_fw component can be exploited to achieve local privilege escalation.\r\n\r\nIf tcf_change_indev() fails, fw_set_parms() will immediately return an error after incrementing or decrementing the reference counter in tcf_bind_filter(). If an attacker can control the reference counter and set it to zero, they can cause the reference to be freed, leading to a use-after-free vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-3776" }, { "cve": "CVE-2023-4004", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A use-after-free flaw was found in the Linux kernel\u0027s netfilter in the way a user triggers the nft_pipapo_remove function with the element, without a NFT_SET_EXT_KEY_END. This issue could allow a local user to crash the system or potentially escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4004" }, { "cve": "CVE-2023-4015", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The netfilter subsystem in the Linux kernel did not properly handle bound chain deactivation in certain circumstances. A local attacker could possibly use this to cause a denial of service (system crash) or execute arbitrary code.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4015" }, { "cve": "CVE-2023-4128", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability in net/sched/cls_fw.c in classifiers (cls_fw, cls_u32, and cls_route) in the Linux Kernel allows a local attacker to perform a local privilege escalation due to incorrect handling of the existing filter, leading to a kernel information leak.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4128" }, { "cve": "CVE-2023-4147", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free vulnerability in the Linux kernel\u2019s Netfilter functionality when adding a rule with NFTA_RULE_CHAIN_ID allows a local user to crash or escalate their privileges on the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4147" }, { "cve": "CVE-2023-4273", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "This vulnerability exists in the implementation of the file name reconstruction function, which is responsible for reading file name entries from a directory index and merging file name parts belonging to one file into a single long file name. Since the file name characters are copied into a stack variable, a local privileged attacker could use this vulnerability to overflow the kernel stack.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4273" }, { "cve": "CVE-2023-4527", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. When the getaddrinfo function is called with the AF_UNSPEC address family and the system is configured with no-aaaa mode via /etc/resolv.conf, a DNS response via TCP larger than 2048 bytes can potentially disclose stack contents through the function returned address data, and may cause a crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4527" }, { "cve": "CVE-2023-4806", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A flaw was found in glibc. In an extremely rare situation, the getaddrinfo function may access memory that has been freed, resulting in an application crash. This issue is only exploitable when a NSS module implements only the _nss_*_gethostbyname2_r and _nss_*_getcanonname_r hooks without implementing the _nss_*_gethostbyname3_r hook. The resolved name should return a large number of IPv6 and IPv4, and the call to the getaddrinfo function should have the AF_INET6 address family with AI_CANONNAME, AI_ALL and AI_V4MAPPED as flags.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4806" }, { "cve": "CVE-2023-4911", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "A buffer overflow was discovered in the GNU C Library\u0027s dynamic loader ld.so while processing the GLIBC_TUNABLES environment variable. This issue could allow a local attacker to use maliciously crafted GLIBC_TUNABLES environment variables when launching binaries with SUID permission to execute code with elevated privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-4911" }, { "cve": "CVE-2023-5156", "cwe": { "id": "CWE-401", "name": "Missing Release of Memory after Effective Lifetime" }, "notes": [ { "category": "summary", "text": "A flaw was found in the GNU C Library. A recent fix for CVE-2023-4806 introduced the potential for a memory leak, which may result in an application crash.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-5156" }, { "cve": "CVE-2023-31248", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Linux Kernel nftables Use-After-Free Local Privilege Escalation Vulnerability; `nft_chain_lookup_byid()` failed to check whether a chain was active and CAP_NET_ADMIN is in any user or network namespace", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-31248" }, { "cve": "CVE-2023-35001", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Linux Kernel nftables Out-Of-Bounds Read/Write Vulnerability; nft_byteorder poorly handled vm register contents when CAP_NET_ADMIN is in any user or network namespace", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-35001" }, { "cve": "CVE-2023-45863", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An issue was discovered in lib/kobject.c in the Linux kernel before 6.2.3. With root access, an attacker can trigger a race condition that results in a fill_kobj_path out-of-bounds write.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V1.3.0 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109945851/" }, { "category": "workaround", "details": "Only build and run applications from trusted sources", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-45863" } ] }
ghsa-xhv3-6p64-vccw
Vulnerability from github
Published
2022-05-24 19:20
Modified
2023-04-26 00:30
Severity ?
Details
A use-after-free in Busybox's awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function
{ "affected": [], "aliases": [ "CVE-2021-42383" ], "database_specific": { "cwe_ids": [ "CWE-416" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-11-15T21:15:00Z", "severity": "HIGH" }, "details": "A use-after-free in Busybox\u0027s awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the evaluate function", "id": "GHSA-xhv3-6p64-vccw", "modified": "2023-04-26T00:30:19Z", "published": "2022-05-24T19:20:50Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-42383" }, { "type": "WEB", "url": "https://claroty.com/team82/research/unboxing-busybox-14-vulnerabilities-uncovered-by-claroty-jfrog" }, { "type": "WEB", "url": "https://jfrog.com/blog/unboxing-busybox-14-new-vulnerabilities-uncovered-by-claroty-and-jfrog" }, { "type": "WEB", "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/6T2TURBYYJGBMQTTN2DSOAIQGP7WCPGV" }, { "type": "WEB", "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/UQXGOGWBIYWOIVXJVRKHZR34UMEHQBXS" }, { "type": "WEB", "url": "https://security.netapp.com/advisory/ntap-20211223-0002" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.