CVE-2021-47816 (GCVE-0-2021-47816)

Vulnerability from cvelistv5 – Published: 2026-01-16 19:09 – Updated: 2026-01-16 20:43
VLAI?
Title
Thecus N4800Eco Nas Server Control Panel - Command Injection
Summary
Thecus N4800Eco NAS Server Control Panel contains a command injection vulnerability that allows authenticated attackers to execute arbitrary system commands through user management endpoints. Attackers can inject commands via username and batch user creation parameters to execute shell commands with administrative privileges.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Credits
Metin Yunus Kandemir
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-47816",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-16T20:42:10.325101Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-16T20:43:27.338Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Thecus N4800Eco Nas Server Control Panel",
          "vendor": "Thecus",
          "versions": [
            {
              "status": "affected",
              "version": "N4800Eco"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Metin Yunus Kandemir"
        }
      ],
      "datePublic": "2021-01-06T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Thecus N4800Eco NAS Server Control Panel contains a command injection vulnerability that allows authenticated attackers to execute arbitrary system commands through user management endpoints. Attackers can inject commands via username and batch user creation parameters to execute shell commands with administrative privileges."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS"
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-16T19:09:26.929Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "name": "ExploitDB-49926",
          "tags": [
            "exploit"
          ],
          "url": "https://www.exploit-db.com/exploits/49926"
        },
        {
          "name": "Thecus Official Vendor Homepage",
          "tags": [
            "product"
          ],
          "url": "http://www.thecus.com/"
        },
        {
          "name": "Thecus N4800Eco Product Page",
          "tags": [
            "product"
          ],
          "url": "http://www.thecus.com/product.php?PROD_ID=83"
        },
        {
          "name": "Researcher Blog",
          "tags": [
            "technical-description",
            "exploit"
          ],
          "url": "https://docs.unsafe-inline.com/0day/thecus-n4800eco-nas-server-control-panel-comand-injection"
        },
        {
          "name": "VulnCheck Advisory: Thecus N4800Eco Nas Server Control Panel - Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.vulncheck.com/advisories/thecus-neco-nas-server-control-panel-command-injection"
        }
      ],
      "title": "Thecus N4800Eco Nas Server Control Panel - Command Injection",
      "x_generator": {
        "engine": "vulncheck"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2021-47816",
    "datePublished": "2026-01-16T19:09:26.929Z",
    "dateReserved": "2026-01-14T17:11:19.895Z",
    "dateUpdated": "2026-01-16T20:43:27.338Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-47816\",\"sourceIdentifier\":\"disclosure@vulncheck.com\",\"published\":\"2026-01-16T19:16:06.197\",\"lastModified\":\"2026-01-16T19:16:06.197\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Thecus N4800Eco NAS Server Control Panel contains a command injection vulnerability that allows authenticated attackers to execute arbitrary system commands through user management endpoints. Attackers can inject commands via username and batch user creation parameters to execute shell commands with administrative privileges.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"LOW\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"http://www.thecus.com/\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"http://www.thecus.com/product.php?PROD_ID=83\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://docs.unsafe-inline.com/0day/thecus-n4800eco-nas-server-control-panel-comand-injection\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://www.exploit-db.com/exploits/49926\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://www.vulncheck.com/advisories/thecus-neco-nas-server-control-panel-command-injection\",\"source\":\"disclosure@vulncheck.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2021-47816\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-01-16T20:42:10.325101Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-01-16T20:42:38.397Z\"}}], \"cna\": {\"title\": \"Thecus N4800Eco Nas Server Control Panel - Command Injection\", \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Metin Yunus Kandemir\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 5.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"LOW\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"LOW\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Thecus\", \"product\": \"Thecus N4800Eco Nas Server Control Panel\", \"versions\": [{\"status\": \"affected\", \"version\": \"N4800Eco\"}]}], \"datePublic\": \"2021-01-06T00:00:00.000Z\", \"references\": [{\"url\": \"https://www.exploit-db.com/exploits/49926\", \"name\": \"ExploitDB-49926\", \"tags\": [\"exploit\"]}, {\"url\": \"http://www.thecus.com/\", \"name\": \"Thecus Official Vendor Homepage\", \"tags\": [\"product\"]}, {\"url\": \"http://www.thecus.com/product.php?PROD_ID=83\", \"name\": \"Thecus N4800Eco Product Page\", \"tags\": [\"product\"]}, {\"url\": \"https://docs.unsafe-inline.com/0day/thecus-n4800eco-nas-server-control-panel-comand-injection\", \"name\": \"Researcher Blog\", \"tags\": [\"technical-description\", \"exploit\"]}, {\"url\": \"https://www.vulncheck.com/advisories/thecus-neco-nas-server-control-panel-command-injection\", \"name\": \"VulnCheck Advisory: Thecus N4800Eco Nas Server Control Panel - Command Injection\", \"tags\": [\"third-party-advisory\"]}], \"x_generator\": {\"engine\": \"vulncheck\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Thecus N4800Eco NAS Server Control Panel contains a command injection vulnerability that allows authenticated attackers to execute arbitrary system commands through user management endpoints. Attackers can inject commands via username and batch user creation parameters to execute shell commands with administrative privileges.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"shortName\": \"VulnCheck\", \"dateUpdated\": \"2026-01-16T19:09:26.929Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2021-47816\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-01-16T20:43:27.338Z\", \"dateReserved\": \"2026-01-14T17:11:19.895Z\", \"assignerOrgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"datePublished\": \"2026-01-16T19:09:26.929Z\", \"assignerShortName\": \"VulnCheck\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…