CVE-2022-20729 (GCVE-0-2022-20729)
Vulnerability from cvelistv5 – Published: 2022-05-03 03:16 – Updated: 2024-11-06 16:18
VLAI?
Summary
A vulnerability in CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to inject XML into the command parser. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by including crafted input in commands. A successful exploit could allow the attacker to inject XML into the command parser, which could result in unexpected processing of the command and unexpected command output.
Severity ?
4.4 (Medium)
CWE
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cisco | Cisco Firepower Threat Defense Software |
Affected:
n/a
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:24:49.226Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20220427 Cisco Firepower Threat Defense Software XML Injection Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-xmlinj-8GWjGzKe"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-20729",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-06T15:58:37.745503Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-06T16:18:45.044Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco Firepower Threat Defense Software",
"vendor": "Cisco",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2022-04-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to inject XML into the command parser. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by including crafted input in commands. A successful exploit could allow the attacker to inject XML into the command parser, which could result in unexpected processing of the command and unexpected command output."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-91",
"description": "CWE-91",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-03T03:16:23",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20220427 Cisco Firepower Threat Defense Software XML Injection Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-xmlinj-8GWjGzKe"
}
],
"source": {
"advisory": "cisco-sa-ftd-xmlinj-8GWjGzKe",
"defect": [
[
"CSCvy41763"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco Firepower Threat Defense Software XML Injection Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2022-04-27T16:00:00",
"ID": "CVE-2022-20729",
"STATE": "PUBLIC",
"TITLE": "Cisco Firepower Threat Defense Software XML Injection Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco Firepower Threat Defense Software",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to inject XML into the command parser. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by including crafted input in commands. A successful exploit could allow the attacker to inject XML into the command parser, which could result in unexpected processing of the command and unexpected command output."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "4.4",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-91"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20220427 Cisco Firepower Threat Defense Software XML Injection Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-xmlinj-8GWjGzKe"
}
]
},
"source": {
"advisory": "cisco-sa-ftd-xmlinj-8GWjGzKe",
"defect": [
[
"CSCvy41763"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2022-20729",
"datePublished": "2022-05-03T03:16:23.220344Z",
"dateReserved": "2021-11-02T00:00:00",
"dateUpdated": "2024-11-06T16:18:45.044Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:cisco:firepower_threat_defense:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.4.0.15\", \"matchCriteriaId\": \"35AD28D3-1C08-44EF-9148-371C9E7912E5\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:cisco:firepower_threat_defense:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"6.5.0\", \"versionEndExcluding\": \"6.6.5.2\", \"matchCriteriaId\": \"CD7675E1-AE0A-4C69-915D-144597F1250E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:cisco:firepower_threat_defense:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"6.7.0\", \"versionEndExcluding\": \"7.0.2\", \"matchCriteriaId\": \"22E1337C-A0EE-467D-A06E-FBE1541DDFD2\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to inject XML into the command parser. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by including crafted input in commands. A successful exploit could allow the attacker to inject XML into the command parser, which could result in unexpected processing of the command and unexpected command output.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en la CLI del software Cisco Firepower Threat Defense (FTD) podr\\u00eda permitir a un atacante local autenticado inyectar XML en el analizador de comandos. Esta vulnerabilidad es debido a una comprobaci\\u00f3n de entrada insuficiente. Un atacante podr\\u00eda explotar esta vulnerabilidad al incluir entradas dise\\u00f1adas en los comandos. Una explotaci\\u00f3n con \\u00e9xito podr\\u00eda permitir al atacante inyectar XML en el analizador de comandos, lo que podr\\u00eda resultar en un procesamiento inesperado del comando y a una salida no esperada del mismo\"}]",
"id": "CVE-2022-20729",
"lastModified": "2024-11-21T06:43:25.883",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N\", \"baseScore\": 4.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 2.5}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 4.6, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.9, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-05-03T04:15:09.063",
"references": "[{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-xmlinj-8GWjGzKe\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-xmlinj-8GWjGzKe\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "ykramarz@cisco.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-91\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-91\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-20729\",\"sourceIdentifier\":\"psirt@cisco.com\",\"published\":\"2022-05-03T04:15:09.063\",\"lastModified\":\"2024-11-21T06:43:25.883\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to inject XML into the command parser. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by including crafted input in commands. A successful exploit could allow the attacker to inject XML into the command parser, which could result in unexpected processing of the command and unexpected command output.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la CLI del software Cisco Firepower Threat Defense (FTD) podr\u00eda permitir a un atacante local autenticado inyectar XML en el analizador de comandos. Esta vulnerabilidad es debido a una comprobaci\u00f3n de entrada insuficiente. Un atacante podr\u00eda explotar esta vulnerabilidad al incluir entradas dise\u00f1adas en los comandos. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante inyectar XML en el analizador de comandos, lo que podr\u00eda resultar en un procesamiento inesperado del comando y a una salida no esperada del mismo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":2.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-91\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-91\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_threat_defense:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.4.0.15\",\"matchCriteriaId\":\"35AD28D3-1C08-44EF-9148-371C9E7912E5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_threat_defense:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.5.0\",\"versionEndExcluding\":\"6.6.5.2\",\"matchCriteriaId\":\"CD7675E1-AE0A-4C69-915D-144597F1250E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_threat_defense:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.7.0\",\"versionEndExcluding\":\"7.0.2\",\"matchCriteriaId\":\"22E1337C-A0EE-467D-A06E-FBE1541DDFD2\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-xmlinj-8GWjGzKe\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-xmlinj-8GWjGzKe\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-xmlinj-8GWjGzKe\", \"name\": \"20220427 Cisco Firepower Threat Defense Software XML Injection Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T02:24:49.226Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-20729\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-06T15:58:37.745503Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-06T15:59:00.256Z\"}}], \"cna\": {\"title\": \"Cisco Firepower Threat Defense Software XML Injection Vulnerability\", \"source\": {\"defect\": [[\"CSCvy41763\"]], \"advisory\": \"cisco-sa-ftd-xmlinj-8GWjGzKe\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.4, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco Firepower Threat Defense Software\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2022-04-27T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-xmlinj-8GWjGzKe\", \"name\": \"20220427 Cisco Firepower Threat Defense Software XML Injection Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to inject XML into the command parser. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by including crafted input in commands. A successful exploit could allow the attacker to inject XML into the command parser, which could result in unexpected processing of the command and unexpected command output.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-91\", \"description\": \"CWE-91\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2022-05-03T03:16:23\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"4.4\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N\"}}, \"source\": {\"defect\": [[\"CSCvy41763\"]], \"advisory\": \"cisco-sa-ftd-xmlinj-8GWjGzKe\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"Cisco Firepower Threat Defense Software\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-xmlinj-8GWjGzKe\", \"name\": \"20220427 Cisco Firepower Threat Defense Software XML Injection Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to inject XML into the command parser. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by including crafted input in commands. A successful exploit could allow the attacker to inject XML into the command parser, which could result in unexpected processing of the command and unexpected command output.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-91\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2022-20729\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco Firepower Threat Defense Software XML Injection Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2022-04-27T16:00:00\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-20729\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-06T16:18:45.044Z\", \"dateReserved\": \"2021-11-02T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2022-05-03T03:16:23.220344Z\", \"assignerShortName\": \"cisco\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…