CVE-2022-20744 (GCVE-0-2022-20744)
Vulnerability from cvelistv5 – Published: 2022-05-03 03:20 – Updated: 2024-11-06 16:17
VLAI?
Summary
A vulnerability in the input protection mechanisms of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to view data without proper authorization. This vulnerability exists because of a protection mechanism that relies on the existence or values of a specific input. An attacker could exploit this vulnerability by modifying this input to bypass the protection mechanism and sending a crafted request to an affected device. A successful exploit could allow the attacker to view data beyond the scope of their authorization.
Severity ?
4.3 (Medium)
CWE
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Cisco | Cisco Firepower Management Center |
Affected:
n/a
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:24:49.811Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20220427 Cisco Firepower Management Center Software Information Disclosure Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-20744",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-06T15:58:32.959124Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-06T16:17:47.846Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco Firepower Management Center",
"vendor": "Cisco",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2022-04-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the input protection mechanisms of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to view data without proper authorization. This vulnerability exists because of a protection mechanism that relies on the existence or values of a specific input. An attacker could exploit this vulnerability by modifying this input to bypass the protection mechanism and sending a crafted request to an affected device. A successful exploit could allow the attacker to view data beyond the scope of their authorization."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-807",
"description": "CWE-807",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-03T03:20:10",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20220427 Cisco Firepower Management Center Software Information Disclosure Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu"
}
],
"source": {
"advisory": "cisco-sa-fmc-infdisc-guJWRwQu",
"defect": [
[
"CSCvt35116"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco Firepower Management Center Software Information Disclosure Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2022-04-27T16:00:00",
"ID": "CVE-2022-20744",
"STATE": "PUBLIC",
"TITLE": "Cisco Firepower Management Center Software Information Disclosure Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco Firepower Management Center",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the input protection mechanisms of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to view data without proper authorization. This vulnerability exists because of a protection mechanism that relies on the existence or values of a specific input. An attacker could exploit this vulnerability by modifying this input to bypass the protection mechanism and sending a crafted request to an affected device. A successful exploit could allow the attacker to view data beyond the scope of their authorization."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "4.3",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-807"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20220427 Cisco Firepower Management Center Software Information Disclosure Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu"
}
]
},
"source": {
"advisory": "cisco-sa-fmc-infdisc-guJWRwQu",
"defect": [
[
"CSCvt35116"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2022-20744",
"datePublished": "2022-05-03T03:20:10.556439Z",
"dateReserved": "2021-11-02T00:00:00",
"dateUpdated": "2024-11-06T16:17:47.846Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:cisco:secure_firewall_management_center:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"7.1.0\", \"matchCriteriaId\": \"F62A86D8-58DA-487A-BB48-30F4879AE9A3\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in the input protection mechanisms of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to view data without proper authorization. This vulnerability exists because of a protection mechanism that relies on the existence or values of a specific input. An attacker could exploit this vulnerability by modifying this input to bypass the protection mechanism and sending a crafted request to an affected device. A successful exploit could allow the attacker to view data beyond the scope of their authorization.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en los mecanismos de protecci\\u00f3n de entrada del software Cisco Firepower Management Center (FMC) podr\\u00eda permitir a un atacante remoto autenticado visualizar datos sin autorizaci\\u00f3n apropiada. Esta vulnerabilidad se presenta debido a un mecanismo de protecci\\u00f3n que es basado en la existencia o los valores de una entrada espec\\u00edfica. Un atacante podr\\u00eda explotar esta vulnerabilidad al modificar esta entrada para omitir el mecanismo de protecci\\u00f3n y vulnerabilidad mediante el env\\u00edo de una petici\\u00f3n dise\\u00f1ada a un dispositivo afectado. Una explotaci\\u00f3n con \\u00e9xito podr\\u00eda permitir al atacante visualizar datos m\\u00e1s all\\u00e1 del alcance de su autorizaci\\u00f3n\"}]",
"id": "CVE-2022-20744",
"lastModified": "2024-11-26T16:09:02.407",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}], \"cvssMetricV30\": [{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\", \"baseScore\": 4.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 1.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:N/A:N\", \"baseScore\": 4.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-05-03T04:15:09.437",
"references": "[{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "ykramarz@cisco.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-807\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-20744\",\"sourceIdentifier\":\"psirt@cisco.com\",\"published\":\"2022-05-03T04:15:09.437\",\"lastModified\":\"2024-11-26T16:09:02.407\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the input protection mechanisms of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to view data without proper authorization. This vulnerability exists because of a protection mechanism that relies on the existence or values of a specific input. An attacker could exploit this vulnerability by modifying this input to bypass the protection mechanism and sending a crafted request to an affected device. A successful exploit could allow the attacker to view data beyond the scope of their authorization.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en los mecanismos de protecci\u00f3n de entrada del software Cisco Firepower Management Center (FMC) podr\u00eda permitir a un atacante remoto autenticado visualizar datos sin autorizaci\u00f3n apropiada. Esta vulnerabilidad se presenta debido a un mecanismo de protecci\u00f3n que es basado en la existencia o los valores de una entrada espec\u00edfica. Un atacante podr\u00eda explotar esta vulnerabilidad al modificar esta entrada para omitir el mecanismo de protecci\u00f3n y vulnerabilidad mediante el env\u00edo de una petici\u00f3n dise\u00f1ada a un dispositivo afectado. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante visualizar datos m\u00e1s all\u00e1 del alcance de su autorizaci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV30\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-807\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.1.0\",\"matchCriteriaId\":\"F62A86D8-58DA-487A-BB48-30F4879AE9A3\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu\", \"name\": \"20220427 Cisco Firepower Management Center Software Information Disclosure Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T02:24:49.811Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-20744\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-06T15:58:32.959124Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-06T15:58:55.522Z\"}}], \"cna\": {\"title\": \"Cisco Firepower Management Center Software Information Disclosure Vulnerability\", \"source\": {\"defect\": [[\"CSCvt35116\"]], \"advisory\": \"cisco-sa-fmc-infdisc-guJWRwQu\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_0\": {\"scope\": \"UNCHANGED\", \"version\": \"3.0\", \"baseScore\": 4.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco Firepower Management Center\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2022-04-27T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu\", \"name\": \"20220427 Cisco Firepower Management Center Software Information Disclosure Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the input protection mechanisms of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to view data without proper authorization. This vulnerability exists because of a protection mechanism that relies on the existence or values of a specific input. An attacker could exploit this vulnerability by modifying this input to bypass the protection mechanism and sending a crafted request to an affected device. A successful exploit could allow the attacker to view data beyond the scope of their authorization.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-807\", \"description\": \"CWE-807\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2022-05-03T03:20:10\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"4.3\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\"}}, \"source\": {\"defect\": [[\"CSCvt35116\"]], \"advisory\": \"cisco-sa-fmc-infdisc-guJWRwQu\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"Cisco Firepower Management Center\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-infdisc-guJWRwQu\", \"name\": \"20220427 Cisco Firepower Management Center Software Information Disclosure Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in the input protection mechanisms of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to view data without proper authorization. This vulnerability exists because of a protection mechanism that relies on the existence or values of a specific input. An attacker could exploit this vulnerability by modifying this input to bypass the protection mechanism and sending a crafted request to an affected device. A successful exploit could allow the attacker to view data beyond the scope of their authorization.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-807\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2022-20744\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco Firepower Management Center Software Information Disclosure Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2022-04-27T16:00:00\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-20744\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-06T16:17:47.846Z\", \"dateReserved\": \"2021-11-02T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2022-05-03T03:20:10.556439Z\", \"assignerShortName\": \"cisco\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…