Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2022-23129
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://jvn.jp/vu/JVNVU95403720/index.html | Mitigation, Third Party Advisory, VDB Entry | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01 | Mitigation, Third Party Advisory, US Government Resource, VDB Entry | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf | Mitigation, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/vu/JVNVU95403720/index.html | Mitigation, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01 | Mitigation, Third Party Advisory, US Government Resource, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf | Mitigation, Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Mitsubishi Electric MC Works64; ICONICS GENESIS64 |
Version: Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior Version: ICONICS GENESIS64 versions 10.90 to 10.97 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:36:19.744Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mitsubishi Electric MC Works64; ICONICS GENESIS64", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior" }, { "status": "affected", "version": "ICONICS GENESIS64 versions 10.90 to 10.97" } ] } ], "descriptions": [ { "lang": "en", "value": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information." } ], "problemTypes": [ { "descriptions": [ { "description": "Plaintext Storage of a Password", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-21T18:17:31", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "ID": "CVE-2022-23129", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mitsubishi Electric MC Works64; ICONICS GENESIS64", "version": { "version_data": [ { "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior" }, { "version_value": "ICONICS GENESIS64 versions 10.90 to 10.97" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Plaintext Storage of a Password" } ] } ] }, "references": { "reference_data": [ { "name": "https://jvn.jp/vu/JVNVU95403720/index.html", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2022-23129", "datePublished": "2022-01-21T18:17:31", "dateReserved": "2022-01-11T00:00:00", "dateUpdated": "2024-08-03T03:36:19.744Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-23129\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2022-01-21T19:15:10.037\",\"lastModified\":\"2024-11-21T06:48:03.540\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de almacenamiento de texto plano de una contrase\u00f1a en Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores y en ICONICS GENESIS64 versiones 10.90 a 10.97, permite a un atacante local autenticado conseguir informaci\u00f3n de autenticaci\u00f3n y acceder a la base de datos de forma ilegal. Esto es debido a que cuando la informaci\u00f3n de configuraci\u00f3n de GridWorX, una funci\u00f3n de enlace de bases de datos de GENESIS64 y MC Works64, es exportada a un archivo CSV, la informaci\u00f3n de autenticaci\u00f3n es guardada en texto plano, y un atacante que pueda acceder a este archivo CSV puede conseguir la informaci\u00f3n de autenticaci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":2.1,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"10.90\",\"versionEndIncluding\":\"10.97\",\"matchCriteriaId\":\"244286B8-A94E-451A-A79F-895B01BCE0FB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"10.95.210.01\",\"matchCriteriaId\":\"D31E1BFD-8194-4BA1-998B-BC4005454C15\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU95403720/index.html\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\",\"VDB Entry\"]},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/vu/JVNVU95403720/index.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\",\"VDB Entry\"]},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}" } }
icsa-22-020-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "ICONICS", "summary": "reporting these vulnerabilities to CISA" }, { "organization": "Mitsubishi Electric", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could result in unauthorized access to information, unauthorized access to GENESIS64 and MC Works64 functionality, or the disabling of SQL Server.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "ICONICS is headquartered in the United States; Mitsubishi Electric is headquartered in Japan", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Do not click web links or open attachments in unsolicited email messages.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-020-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-020-01.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-22-020-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-020-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ICONICS and Mitsubishi Electric HMI SCADA", "tracking": { "current_release_date": "2022-01-20T07:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-020-01", "initial_release_date": "2022-01-20T07:00:00.000000Z", "revision_history": [ { "date": "2022-01-20T07:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c=10.96.2", "product": { "name": "ICONICS ICONICS Suite GENESIS64: \u003c=10.96.2", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "ICONICS Suite GENESIS64" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.96.2", "product": { "name": "ICONICS ICONICS Suite Hyper Historian: \u003c=10.96.2", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "ICONICS Suite Hyper Historian" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.96.2", "product": { "name": "ICONICS ICONICS Suite AnalytiX: \u003c=10.96.2", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "ICONICS Suite AnalytiX" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.96.2", "product": { "name": "ICONICS ICONICS Suite MobileHMI: \u003c=10.96.2", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "ICONICS Suite MobileHMI" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.95.3|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite GENESIS64: \u003e=10.95.3|\u003c=10.97", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "ICONICS Suite GENESIS64" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.95.3|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite Hyper Historian: \u003e=10.95.3|\u003c=10.97", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "ICONICS Suite Hyper Historian" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.95.3|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite AnalytiX: \u003e=10.95.3|\u003c=10.97", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "ICONICS Suite AnalytiX" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.95.3|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite MobileHMI: \u003e=10.95.3|\u003c=10.97", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "ICONICS Suite MobileHMI" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.90|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite GENESIS64: \u003e=10.90|\u003c=10.97", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "ICONICS Suite GENESIS64" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.90|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite Hyper Historian: \u003e=10.90|\u003c=10.97", "product_id": "CSAFPID-0010" } } ], "category": "product_name", "name": "ICONICS Suite Hyper Historian" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.90|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite AnalytiX: \u003e=10.90|\u003c=10.97", "product_id": "CSAFPID-0011" } } ], "category": "product_name", "name": "ICONICS Suite AnalytiX" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.90|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite MobileHMI: \u003e=10.90|\u003c=10.97", "product_id": "CSAFPID-0012" } } ], "category": "product_name", "name": "ICONICS Suite MobileHMI" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite GENESIS64: \u003c=10.97", "product_id": "CSAFPID-0013" } } ], "category": "product_name", "name": "ICONICS Suite GENESIS64" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite Hyper Historian: \u003c=10.97", "product_id": "CSAFPID-0014" } } ], "category": "product_name", "name": "ICONICS Suite Hyper Historian" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite AnalytiX: \u003c=10.97", "product_id": "CSAFPID-0015" } } ], "category": "product_name", "name": "ICONICS Suite AnalytiX" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite MobileHMI: \u003c=10.97", "product_id": "CSAFPID-0016" } } ], "category": "product_name", "name": "ICONICS Suite MobileHMI" } ], "category": "vendor", "name": "ICONICS" }, { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c4.04E_10.95.210.01", "product": { "name": "Mitsubishi Electric MC Works64: \u003c4.04E_10.95.210.01", "product_id": "CSAFPID-0017" } } ], "category": "product_name", "name": "MC Works64" }, { "branches": [ { "category": "product_version_range", "name": "\u003c4.04E_10.95.210.01", "product": { "name": "Mitsubishi Electric MC Works64: \u003c4.04E_10.95.210.01", "product_id": "CSAFPID-0018" } } ], "category": "product_name", "name": "MC Works64" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=4.00A_v10.95.201.23|\u003c=4.04E_v10.95.210.01", "product": { "name": "Mitsubishi Electric MC Works64: \u003e=4.00A_v10.95.201.23|\u003c=4.04E_v10.95.210.01", "product_id": "CSAFPID-0019" } } ], "category": "product_name", "name": "MC Works64" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=4.00A_v10.95.201.23|\u003c=4.04E_v10.95.210.01", "product": { "name": "Mitsubishi Electric MC Works64: \u003e=4.00A_v10.95.201.23|\u003c=4.04E_v10.95.210.01", "product_id": "CSAFPID-0020" } } ], "category": "product_name", "name": "MC Works64" } ], "category": "vendor", "name": "Mitsubishi Electric" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-23127", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "ICONICS MobileHMI and Mitsubishi Electric MC Mobile products lack proper validation checks on user input and external data when they are used to render a page to the client.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23127" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric are releasing critical fixes rollups or patches for these products. GENESIS64 Version 10.97.1 and later will not be vulnerable to these exploits.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ], "url": "http://www.iconics.com/certs" }, { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric recommend users of these products take the following mitigation steps:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, { "category": "mitigation", "details": "Use a firewall. Place control system networks and devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices. Control system devices should not directly face the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, { "category": "mitigation", "details": "Do not click web links or open unsolicited attachments in e-mail messages.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, { "category": "mitigation", "details": "Install the applicable critical fixes/rollup releases when available.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the GENESIS64 security updates on the ICONICS website.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ], "url": "https://iconics.com/certs" }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the MC Work64 security updates on the Mitsubishi Electric website.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/index.html" } ], "scores": [ { "cvss_v3": { "baseScore": 4.2, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] } ] }, { "cve": "CVE-2022-23128", "cwe": { "id": "CWE-184", "name": "Incomplete List of Disallowed Inputs" }, "notes": [ { "category": "summary", "text": "The FrameWorX Server in all ICONICS Suite and Mitsubishi Electric MC Works64 products can allow an attacker to bypass GENESIS64 /MC Works64 security when opening a communication channel to the WebSocket endpoint (Port 80 or 443) of the FrameWorX Server.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23128" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric are releasing critical fixes rollups or patches for these products. GENESIS64 Version 10.97.1 and later will not be vulnerable to these exploits.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ], "url": "http://www.iconics.com/certs" }, { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric recommend users of these products take the following mitigation steps:", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, { "category": "mitigation", "details": "Use a firewall. Place control system networks and devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices. Control system devices should not directly face the Internet.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, { "category": "mitigation", "details": "Do not click web links or open unsolicited attachments in e-mail messages.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, { "category": "mitigation", "details": "Install the applicable critical fixes/rollup releases when available.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the GENESIS64 security updates on the ICONICS website.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ], "url": "https://iconics.com/certs" }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the MC Work64 security updates on the Mitsubishi Electric website.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/index.html" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] } ] }, { "cve": "CVE-2022-23129", "cwe": { "id": "CWE-256", "name": "Plaintext Storage of a Password" }, "notes": [ { "category": "summary", "text": "The GENESIS64 and MC Works64 Workbench export to CSV function may expose a password in plain text when used to export the GridWorX Server configuration.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23129" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric are releasing critical fixes rollups or patches for these products. GENESIS64 Version 10.97.1 and later will not be vulnerable to these exploits.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ], "url": "http://www.iconics.com/certs" }, { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric recommend users of these products take the following mitigation steps:", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "Use a firewall. Place control system networks and devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices. Control system devices should not directly face the Internet.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "Do not click web links or open unsolicited attachments in e-mail messages.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "Install the applicable critical fixes/rollup releases when available.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the GENESIS64 security updates on the ICONICS website.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ], "url": "https://iconics.com/certs" }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the MC Work64 security updates on the Mitsubishi Electric website.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/index.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.7, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] } ] }, { "cve": "CVE-2022-23130", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "A coding error in the SQL query engine memory allocation code makes it possible to execute a series of SQL commands in a GENESIS64 system or a MC Works64 system, which could cause a crash of the SQL Query Engine and result in the disabling of the SQL Server.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23130" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:H/UI:R/S:C/C:N/I:L/A:H" } ], "remediations": [ { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric are releasing critical fixes rollups or patches for these products. GENESIS64 Version 10.97.1 and later will not be vulnerable to these exploits.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ], "url": "http://www.iconics.com/certs" }, { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric recommend users of these products take the following mitigation steps:", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, { "category": "mitigation", "details": "Use a firewall. Place control system networks and devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices. Control system devices should not directly face the Internet.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, { "category": "mitigation", "details": "Do not click web links or open unsolicited attachments in e-mail messages.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, { "category": "mitigation", "details": "Install the applicable critical fixes/rollup releases when available.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the GENESIS64 security updates on the ICONICS website.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ], "url": "https://iconics.com/certs" }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the MC Work64 security updates on the Mitsubishi Electric website.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/index.html" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:A/AC:H/PR:H/UI:R/S:C/C:N/I:L/A:H", "version": "3.0" }, "products": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] } ] } ] }
ICSA-22-020-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "ICONICS", "summary": "reporting these vulnerabilities to CISA" }, { "organization": "Mitsubishi Electric", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could result in unauthorized access to information, unauthorized access to GENESIS64 and MC Works64 functionality, or the disabling of SQL Server.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "ICONICS is headquartered in the United States; Mitsubishi Electric is headquartered in Japan", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Do not click web links or open attachments in unsolicited email messages.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.", "title": "Recommended Practices" }, { "category": "general", "text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-020-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-020-01.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-22-020-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-020-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ICONICS and Mitsubishi Electric HMI SCADA", "tracking": { "current_release_date": "2022-01-20T07:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-020-01", "initial_release_date": "2022-01-20T07:00:00.000000Z", "revision_history": [ { "date": "2022-01-20T07:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c=10.96.2", "product": { "name": "ICONICS ICONICS Suite GENESIS64: \u003c=10.96.2", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "ICONICS Suite GENESIS64" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.96.2", "product": { "name": "ICONICS ICONICS Suite Hyper Historian: \u003c=10.96.2", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "ICONICS Suite Hyper Historian" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.96.2", "product": { "name": "ICONICS ICONICS Suite AnalytiX: \u003c=10.96.2", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "ICONICS Suite AnalytiX" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.96.2", "product": { "name": "ICONICS ICONICS Suite MobileHMI: \u003c=10.96.2", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "ICONICS Suite MobileHMI" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.95.3|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite GENESIS64: \u003e=10.95.3|\u003c=10.97", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "ICONICS Suite GENESIS64" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.95.3|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite Hyper Historian: \u003e=10.95.3|\u003c=10.97", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "ICONICS Suite Hyper Historian" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.95.3|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite AnalytiX: \u003e=10.95.3|\u003c=10.97", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "ICONICS Suite AnalytiX" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.95.3|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite MobileHMI: \u003e=10.95.3|\u003c=10.97", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "ICONICS Suite MobileHMI" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.90|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite GENESIS64: \u003e=10.90|\u003c=10.97", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "ICONICS Suite GENESIS64" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.90|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite Hyper Historian: \u003e=10.90|\u003c=10.97", "product_id": "CSAFPID-0010" } } ], "category": "product_name", "name": "ICONICS Suite Hyper Historian" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.90|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite AnalytiX: \u003e=10.90|\u003c=10.97", "product_id": "CSAFPID-0011" } } ], "category": "product_name", "name": "ICONICS Suite AnalytiX" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=10.90|\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite MobileHMI: \u003e=10.90|\u003c=10.97", "product_id": "CSAFPID-0012" } } ], "category": "product_name", "name": "ICONICS Suite MobileHMI" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite GENESIS64: \u003c=10.97", "product_id": "CSAFPID-0013" } } ], "category": "product_name", "name": "ICONICS Suite GENESIS64" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite Hyper Historian: \u003c=10.97", "product_id": "CSAFPID-0014" } } ], "category": "product_name", "name": "ICONICS Suite Hyper Historian" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite AnalytiX: \u003c=10.97", "product_id": "CSAFPID-0015" } } ], "category": "product_name", "name": "ICONICS Suite AnalytiX" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=10.97", "product": { "name": "ICONICS ICONICS Suite MobileHMI: \u003c=10.97", "product_id": "CSAFPID-0016" } } ], "category": "product_name", "name": "ICONICS Suite MobileHMI" } ], "category": "vendor", "name": "ICONICS" }, { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c4.04E_10.95.210.01", "product": { "name": "Mitsubishi Electric MC Works64: \u003c4.04E_10.95.210.01", "product_id": "CSAFPID-0017" } } ], "category": "product_name", "name": "MC Works64" }, { "branches": [ { "category": "product_version_range", "name": "\u003c4.04E_10.95.210.01", "product": { "name": "Mitsubishi Electric MC Works64: \u003c4.04E_10.95.210.01", "product_id": "CSAFPID-0018" } } ], "category": "product_name", "name": "MC Works64" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=4.00A_v10.95.201.23|\u003c=4.04E_v10.95.210.01", "product": { "name": "Mitsubishi Electric MC Works64: \u003e=4.00A_v10.95.201.23|\u003c=4.04E_v10.95.210.01", "product_id": "CSAFPID-0019" } } ], "category": "product_name", "name": "MC Works64" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=4.00A_v10.95.201.23|\u003c=4.04E_v10.95.210.01", "product": { "name": "Mitsubishi Electric MC Works64: \u003e=4.00A_v10.95.201.23|\u003c=4.04E_v10.95.210.01", "product_id": "CSAFPID-0020" } } ], "category": "product_name", "name": "MC Works64" } ], "category": "vendor", "name": "Mitsubishi Electric" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-23127", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "ICONICS MobileHMI and Mitsubishi Electric MC Mobile products lack proper validation checks on user input and external data when they are used to render a page to the client.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23127" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric are releasing critical fixes rollups or patches for these products. GENESIS64 Version 10.97.1 and later will not be vulnerable to these exploits.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ], "url": "http://www.iconics.com/certs" }, { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric recommend users of these products take the following mitigation steps:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, { "category": "mitigation", "details": "Use a firewall. Place control system networks and devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices. Control system devices should not directly face the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, { "category": "mitigation", "details": "Do not click web links or open unsolicited attachments in e-mail messages.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, { "category": "mitigation", "details": "Install the applicable critical fixes/rollup releases when available.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the GENESIS64 security updates on the ICONICS website.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ], "url": "https://iconics.com/certs" }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the MC Work64 security updates on the Mitsubishi Electric website.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/index.html" } ], "scores": [ { "cvss_v3": { "baseScore": 4.2, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0017" ] } ] }, { "cve": "CVE-2022-23128", "cwe": { "id": "CWE-184", "name": "Incomplete List of Disallowed Inputs" }, "notes": [ { "category": "summary", "text": "The FrameWorX Server in all ICONICS Suite and Mitsubishi Electric MC Works64 products can allow an attacker to bypass GENESIS64 /MC Works64 security when opening a communication channel to the WebSocket endpoint (Port 80 or 443) of the FrameWorX Server.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23128" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric are releasing critical fixes rollups or patches for these products. GENESIS64 Version 10.97.1 and later will not be vulnerable to these exploits.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ], "url": "http://www.iconics.com/certs" }, { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric recommend users of these products take the following mitigation steps:", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, { "category": "mitigation", "details": "Use a firewall. Place control system networks and devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices. Control system devices should not directly face the Internet.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, { "category": "mitigation", "details": "Do not click web links or open unsolicited attachments in e-mail messages.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, { "category": "mitigation", "details": "Install the applicable critical fixes/rollup releases when available.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the GENESIS64 security updates on the ICONICS website.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ], "url": "https://iconics.com/certs" }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the MC Work64 security updates on the Mitsubishi Electric website.", "product_ids": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/index.html" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0020" ] } ] }, { "cve": "CVE-2022-23129", "cwe": { "id": "CWE-256", "name": "Plaintext Storage of a Password" }, "notes": [ { "category": "summary", "text": "The GENESIS64 and MC Works64 Workbench export to CSV function may expose a password in plain text when used to export the GridWorX Server configuration.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23129" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric are releasing critical fixes rollups or patches for these products. GENESIS64 Version 10.97.1 and later will not be vulnerable to these exploits.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ], "url": "http://www.iconics.com/certs" }, { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric recommend users of these products take the following mitigation steps:", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "Use a firewall. Place control system networks and devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices. Control system devices should not directly face the Internet.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "Do not click web links or open unsolicited attachments in e-mail messages.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "Install the applicable critical fixes/rollup releases when available.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the GENESIS64 security updates on the ICONICS website.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ], "url": "https://iconics.com/certs" }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the MC Work64 security updates on the Mitsubishi Electric website.", "product_ids": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/index.html" } ], "scores": [ { "cvss_v3": { "baseScore": 7.7, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0018" ] } ] }, { "cve": "CVE-2022-23130", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "A coding error in the SQL query engine memory allocation code makes it possible to execute a series of SQL commands in a GENESIS64 system or a MC Works64 system, which could cause a crash of the SQL Query Engine and result in the disabling of the SQL Server.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2022-23130" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:H/UI:R/S:C/C:N/I:L/A:H" } ], "remediations": [ { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric are releasing critical fixes rollups or patches for these products. GENESIS64 Version 10.97.1 and later will not be vulnerable to these exploits.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ], "url": "http://www.iconics.com/certs" }, { "category": "mitigation", "details": "ICONICS and Mitsubishi Electric recommend users of these products take the following mitigation steps:", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, { "category": "mitigation", "details": "Use a firewall. Place control system networks and devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices. Control system devices should not directly face the Internet.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, { "category": "mitigation", "details": "Do not click web links or open unsolicited attachments in e-mail messages.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, { "category": "mitigation", "details": "Install the applicable critical fixes/rollup releases when available.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the GENESIS64 security updates on the ICONICS website.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ], "url": "https://iconics.com/certs" }, { "category": "mitigation", "details": "Users can find additional information and useful links related to the MC Work64 security updates on the Mitsubishi Electric website.", "product_ids": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/index.html" } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:A/AC:H/PR:H/UI:R/S:C/C:N/I:L/A:H", "version": "3.0" }, "products": [ "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0019" ] } ] } ] }
var-202201-0606
Vulnerability from variot
Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information. Mitsubishi Electric MC Works64 and ICONICS GENESIS64 There is a vulnerability in plaintext storage of important information.Information may be obtained
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202201-0606", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "genesis64", "scope": "lte", "trust": 1.0, "vendor": "iconics", "version": "10.97" }, { "model": "mc works64", "scope": "lt", "trust": 1.0, "vendor": "mitsubishielectric", "version": "10.95.210.01" }, { "model": "genesis64", "scope": "gte", "trust": 1.0, "vendor": "iconics", "version": "10.90" }, { "model": "genesis 64", "scope": null, "trust": 0.8, "vendor": "iconics", "version": null }, { "model": "mc works64", "scope": "lte", "trust": 0.8, "vendor": "\u4e09\u83f1\u96fb\u6a5f", "version": "4.04e (10.95.210.01) and earlier" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "10.97", "versionStartIncluding": "10.90", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "10.95.210.01", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-23129" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "ICONICS and Mitsubishi Electric reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-1795" } ], "trust": 0.6 }, "cve": "CVE-2022-23129", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CVE-2022-23129", "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.8, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2022-23129", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-23129", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-23129", "trust": 1.8, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202201-1795", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information. Mitsubishi Electric MC Works64 and ICONICS GENESIS64 There is a vulnerability in plaintext storage of important information.Information may be obtained", "sources": [ { "db": "NVD", "id": "CVE-2022-23129" }, { "db": "JVNDB", "id": "JVNDB-2022-003879" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-23129", "trust": 3.2 }, { "db": "JVN", "id": "JVNVU95403720", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-22-020-01", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2022-003879", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2022.0311", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022012109", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202201-1795", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "id": "VAR-202201-0606", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.42615384 }, "last_update_date": "2023-03-11T22:22:54.544000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page Mitsubishi Electric Mitsubishi\u00a0Electric\u00a0Corporation", "trust": 0.8, "url": "https://iconics.com/" }, { "title": "Mitsubishi Electric MC Works64 Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=179834" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "CNNVD", "id": "CNNVD-202201-1795" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-312", "trust": 1.0 }, { "problemtype": "Plaintext storage of important information (CWE-312) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01" }, { "trust": 1.6, "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf" }, { "trust": 1.6, "url": "https://jvn.jp/vu/jvnvu95403720/index.html" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-23129" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu95403720/" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-020-01" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.0311" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/iconics-genesis64-four-vulnerabilities-37339" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022012109" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "db": "NVD", "id": "CVE-2022-23129" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "date": "2022-01-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "date": "2022-01-21T19:15:00", "db": "NVD", "id": "CVE-2022-23129" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-10T03:13:00", "db": "JVNDB", "id": "JVNDB-2022-003879" }, { "date": "2022-02-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202201-1795" }, { "date": "2022-01-27T20:09:00", "db": "NVD", "id": "CVE-2022-23129" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-1795" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mitsubishi\u00a0Electric\u00a0MC\u00a0Works64\u00a0 and \u00a0ICONICS\u00a0GENESIS64\u00a0 Vulnerability in plaintext storage of important information in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003879" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-1795" } ], "trust": 0.6 } }
gsd-2022-23129
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-23129", "description": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.", "id": "GSD-2022-23129" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-23129" ], "details": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.", "id": "GSD-2022-23129", "modified": "2023-12-13T01:19:35.482333Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "ID": "CVE-2022-23129", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mitsubishi Electric MC Works64; ICONICS GENESIS64", "version": { "version_data": [ { "version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior" }, { "version_value": "ICONICS GENESIS64 versions 10.90 to 10.97" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Plaintext Storage of a Password" } ] } ] }, "references": { "reference_data": [ { "name": "https://jvn.jp/vu/JVNVU95403720/index.html", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "10.97", "versionStartIncluding": "10.90", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "10.95.210.01", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "ID": "CVE-2022-23129" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-312" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01", "refsource": "MISC", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource", "VDB Entry" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01" }, { "name": "https://jvn.jp/vu/JVNVU95403720/index.html", "refsource": "MISC", "tags": [ "Mitigation", "Third Party Advisory", "VDB Entry" ], "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf", "refsource": "MISC", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6 } }, "lastModifiedDate": "2022-01-27T20:09Z", "publishedDate": "2022-01-21T19:15Z" } } }
ghsa-v8qm-c69g-x57q
Vulnerability from github
Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.
{ "affected": [], "aliases": [ "CVE-2022-23129" ], "database_specific": { "cwe_ids": [ "CWE-312" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-01-21T19:15:00Z", "severity": "MODERATE" }, "details": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.", "id": "GHSA-v8qm-c69g-x57q", "modified": "2022-01-28T00:03:11Z", "published": "2022-01-22T00:00:21Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-23129" }, { "type": "WEB", "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "type": "WEB", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01" }, { "type": "WEB", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf" } ], "schema_version": "1.4.0", "severity": [] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.