A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
References
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:43:45.997Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Energy Manager Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Update 1"
            }
          ]
        },
        {
          "product": "SIMATIC Energy Manager PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Update 1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427: Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:37",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-23449",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC Energy Manager Basic",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Update 1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Energy Manager PRO",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Update 1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-427: Uncontrolled Search Path Element"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-23449",
    "datePublished": "2022-04-12T09:07:37",
    "dateReserved": "2022-01-19T00:00:00",
    "dateUpdated": "2024-08-03T03:43:45.997Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-23449\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-04-12T09:15:14.297\",\"lastModified\":\"2022-04-19T16:09:44.513\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC Energy Manager Basic (todas las versiones anteriores a V7.3 Update 1), SIMATIC Energy Manager PRO (todas las versiones anteriores a V7.3 Update 1). Una vulnerabilidad de DLL Hijacking podr\u00eda permitir a un atacante local ejecutar c\u00f3digo con altos privilegios al colocar una DLL maliciosa en uno de los directorios de la ruta de b\u00fasqueda de DLL\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.3,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:M/Au:N/C:C/I:C/A:C\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":6.9},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.4,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-427\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-427\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.3\",\"matchCriteriaId\":\"2BDBCB2C-E9EB-4AF6-B47A-22B27AE41178\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"1BB78E93-7C0A-4F59-B6EA-3D5A681BFE8F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.3\",\"matchCriteriaId\":\"4B1E608C-3C6F-45FB-86C9-E99E7F21836D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"34A11AF9-7F0C-4151-8A4D-A8E1BDCBA525\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.