CVE-2022-23822 (GCVE-0-2022-23822)

Vulnerability from cvelistv5 – Published: 2022-04-27 16:06 – Updated: 2024-09-16 22:25
VLAI?
Summary
In this physical attack, an attacker may potentially exploit the Zynq-7000 SoC First Stage Boot Loader (FSBL) by bypassing authentication and loading a malicious image onto the device. This in turn may further allow the attacker to perform additional attacks such as such as using the device as a decryption oracle. An anticipated mitigation via a 2022.1 patch will resolve the issue.
Severity ?
No CVSS data available.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
AMD
Impacted products
Vendor Product Version
AMD-Xilinx Zynq-7000 SoC FSBL Affected: 2021.2 , ≤ 2022.1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:51:46.057Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.xilinx.com/s/article/76974"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Xilinx/embeddedsw/tree/master/lib/sw_apps/zynq_fsbl"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "Zynq-7000 SoC FSBL"
          ],
          "product": "Zynq-7000 SoC FSBL",
          "vendor": "AMD-Xilinx",
          "versions": [
            {
              "lessThanOrEqual": "2022.1",
              "status": "affected",
              "version": "2021.2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In this physical attack, an attacker may potentially exploit the Zynq-7000 SoC First Stage Boot Loader (FSBL) by bypassing authentication and loading a malicious image onto the device. This in turn may further allow the attacker to perform additional attacks such as such as using the device as a decryption oracle. An anticipated mitigation via a 2022.1 patch will resolve the issue."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863 Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-27T16:06:05",
        "orgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
        "shortName": "AMD"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.xilinx.com/s/article/76974"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Xilinx/embeddedsw/tree/master/lib/sw_apps/zynq_fsbl"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@amd.com",
          "DATE_PUBLIC": "2022-04-26T15:00:00.000Z",
          "ID": "CVE-2022-23822",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Zynq-7000 SoC FSBL",
                      "version": {
                        "version_data": [
                          {
                            "platform": "Zynq-7000 SoC FSBL",
                            "version_affected": "\u003c=",
                            "version_name": "2021.2",
                            "version_value": "2022.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "AMD-Xilinx"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In this physical attack, an attacker may potentially exploit the Zynq-7000 SoC First Stage Boot Loader (FSBL) by bypassing authentication and loading a malicious image onto the device. This in turn may further allow the attacker to perform additional attacks such as such as using the device as a decryption oracle. An anticipated mitigation via a 2022.1 patch will resolve the issue."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-863 Incorrect Authorization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.xilinx.com/s/article/76974",
              "refsource": "MISC",
              "url": "https://support.xilinx.com/s/article/76974"
            },
            {
              "name": "https://github.com/Xilinx/embeddedsw/tree/master/lib/sw_apps/zynq_fsbl",
              "refsource": "MISC",
              "url": "https://github.com/Xilinx/embeddedsw/tree/master/lib/sw_apps/zynq_fsbl"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
    "assignerShortName": "AMD",
    "cveId": "CVE-2022-23822",
    "datePublished": "2022-04-27T16:06:05.276121Z",
    "dateReserved": "2022-01-21T00:00:00",
    "dateUpdated": "2024-09-16T22:25:01.331Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:xilinx:zynq-7000s_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2022.1\", \"matchCriteriaId\": \"D610CBD4-00AC-4470-8E66-5B73AC4D3E3A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:xilinx:zynq-7000s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5B820E50-D48F-47C1-BC7F-2823E4948674\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:xilinx:zynq-7000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2022.1\", \"matchCriteriaId\": \"7A7A35D1-17A0-49DD-9D7F-E4ACA5C57BAE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:xilinx:zynq-7000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A733B279-FD2C-4F20-B220-4D42CD82AB35\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"In this physical attack, an attacker may potentially exploit the Zynq-7000 SoC First Stage Boot Loader (FSBL) by bypassing authentication and loading a malicious image onto the device. This in turn may further allow the attacker to perform additional attacks such as such as using the device as a decryption oracle. An anticipated mitigation via a 2022.1 patch will resolve the issue.\"}, {\"lang\": \"es\", \"value\": \"En este ataque f\\u00edsico, un atacante puede explotar el cargador de arranque de primera etapa (FSBL) del SoC Zynq-7000 evitando la autenticaci\\u00f3n y cargando una imagen maliciosa en el dispositivo. Esto, a su vez, puede permitir al atacante llevar a cabo otros ataques, como por ejemplo usar el dispositivo como or\\u00e1culo de descifrado. Una mitigaci\\u00f3n anticipada por medio de un parche 2022.1 resolver\\u00e1 el problema\"}]",
      "id": "CVE-2022-23822",
      "lastModified": "2024-11-21T06:49:19.200",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"PHYSICAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 4.4, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.4, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2022-04-27T17:15:07.517",
      "references": "[{\"url\": \"https://github.com/Xilinx/embeddedsw/tree/master/lib/sw_apps/zynq_fsbl\", \"source\": \"psirt@amd.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://support.xilinx.com/s/article/76974\", \"source\": \"psirt@amd.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://github.com/Xilinx/embeddedsw/tree/master/lib/sw_apps/zynq_fsbl\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://support.xilinx.com/s/article/76974\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "psirt@amd.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"psirt@amd.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-863\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-863\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-23822\",\"sourceIdentifier\":\"psirt@amd.com\",\"published\":\"2022-04-27T17:15:07.517\",\"lastModified\":\"2024-11-21T06:49:19.200\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In this physical attack, an attacker may potentially exploit the Zynq-7000 SoC First Stage Boot Loader (FSBL) by bypassing authentication and loading a malicious image onto the device. This in turn may further allow the attacker to perform additional attacks such as such as using the device as a decryption oracle. An anticipated mitigation via a 2022.1 patch will resolve the issue.\"},{\"lang\":\"es\",\"value\":\"En este ataque f\u00edsico, un atacante puede explotar el cargador de arranque de primera etapa (FSBL) del SoC Zynq-7000 evitando la autenticaci\u00f3n y cargando una imagen maliciosa en el dispositivo. Esto, a su vez, puede permitir al atacante llevar a cabo otros ataques, como por ejemplo usar el dispositivo como or\u00e1culo de descifrado. Una mitigaci\u00f3n anticipada por medio de un parche 2022.1 resolver\u00e1 el problema\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":4.4,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.4,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@amd.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:xilinx:zynq-7000s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1\",\"matchCriteriaId\":\"D610CBD4-00AC-4470-8E66-5B73AC4D3E3A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:xilinx:zynq-7000s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5B820E50-D48F-47C1-BC7F-2823E4948674\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:xilinx:zynq-7000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.1\",\"matchCriteriaId\":\"7A7A35D1-17A0-49DD-9D7F-E4ACA5C57BAE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:xilinx:zynq-7000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A733B279-FD2C-4F20-B220-4D42CD82AB35\"}]}]}],\"references\":[{\"url\":\"https://github.com/Xilinx/embeddedsw/tree/master/lib/sw_apps/zynq_fsbl\",\"source\":\"psirt@amd.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://support.xilinx.com/s/article/76974\",\"source\":\"psirt@amd.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://github.com/Xilinx/embeddedsw/tree/master/lib/sw_apps/zynq_fsbl\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://support.xilinx.com/s/article/76974\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…