Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2022-25754
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf | Mitigation, Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf | Mitigation, Patch, Vendor Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T04:49:43.242Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-352", "description": "CWE-352: Cross-Site Request Forgery (CSRF)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-12T09:07:49", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-25754", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X302-7 EEC (230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X304-2FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X306-1LD FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-3", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-3", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-3LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-3LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LH", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LH", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LH+", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LH+", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M PoE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M PoE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M TS", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M TS", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X310", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X310", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X310FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X310FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X320-1 FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X320-1-2LD FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X408-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M TS (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M TS (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SIPLUS NET SCALANCE X308-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-352: Cross-Site Request Forgery (CSRF)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-25754", "datePublished": "2022-04-12T09:07:49", "dateReserved": "2022-02-22T00:00:00", "dateUpdated": "2024-08-03T04:49:43.242Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"7FB6F150-2662-44AE-8DC1-0B0A426E8352\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C8E97B3B-1808-45D2-97B7-CF31CA6E7A60\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"E9F4071F-1AE2-4FAD-A8CB-1619552101A3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0087A1C6-AA76-4FD6-BAA1-D3190D2A0116\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"4B78CFDF-1B15-4A4B-99D4-8CC5E1867BD1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"880CF41B-B25D-4744-8E8B-C4B131932B1B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"CCB1094D-3F8A-4331-ABB9-46B73F7E008F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"804EE08B-75A1-4CF6-9C30-8CF0CDC39658\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"EE21803A-A5CA-482A-ABD2-C9A547831BF6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"EEBFBB10-35E0-46BB-A937-E9A933C4D5BC\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7737F0C2-43FC-4330-88F2-9B08BA5B35D7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"4C91F6DD-A74C-4310-88AB-63A39D0208BE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6CCED3E4-38EF-4645-B25C-4F2C3D4E091C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"6B5513D8-59DD-4EE1-B2E8-F800D1DA7BC5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FE1909FA-C8C6-46BE-83C6-2635D36FE69B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"A11DE626-D744-49A7-93C4-FE2C2AF5245F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6DDBD94D-5312-4A54-AF76-D9DF791C0292\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x308-2lh\\\\+_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"DC259CD1-5C79-4491-B375-7A69116F2747\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x308-2lh\\\\+:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"85153EED-C677-495D-A6BB-72365DE1ED3F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"79918934-7B0B-4032-972E-2347CD33029D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AC54911E-C432-48FA-9551-9644422FFE14\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"00FBD442-84AA-48F3-8AD1-5767FFB2FC3F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3E22C57C-2BD6-4C39-93D2-5D81A58EA6F0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"E72D4503-5AAE-4C6F-BAE9-FA51701191B1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DFCCB68C-A58D-4543-A11F-721B01FFBBA4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"CA2333C8-E9C7-43D8-9EAA-A88ECAAB4236\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7FE3716E-1C0A-4B72-809A-8318E5853FB1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"7EECD381-262F-4C47-90E1-7B44092C74BD\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8FB34E83-83A3-45C3-B040-D8910971D439\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"36C40232-5696-44CC-B38F-5331A745C760\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CC54880F-CBF4-4772-A4FB-B07D97287D44\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"2F1969E4-CFD6-4AC7-956E-374967F5C406\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B2D400F5-AD80-4536-A99D-793E1560757B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"3ACB931D-C484-42F4-9912-24B44FE97017\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0C632B90-EB11-4A4C-8128-DABBE044B9AF\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"B1EFA152-D29B-4116-A3D2-ACF7A025E053\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6F952542-6B79-4681-A236-15C188AAEB1E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"935CD21D-0471-4D1F-AF81-B1F996A9EFAB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"664D9C76-BC13-4874-939C-A8211DA33903\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"E2C0F1FB-8B5E-448C-A304-FDDCB3DFCDD4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4834A67B-7B0B-4F88-BBFB-25667FD68EC5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"3E0E1F54-D9EA-4AFB-80EF-0A585EC3C641\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"36C9AE74-4683-4ED0-A605-3A6B065C230E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"DC03DF92-C7A1-4232-AFDF-04B2B50666DB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4356417E-B4CB-45B0-B395-CE9D423FAB44\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1.4\", \"matchCriteriaId\": \"25103533-B9BC-4553-B195-AF5CACAB713B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9C48C944-324B-4390-B9D1-3D0FC3DD5BFD\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, revestido), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, revestido), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, revestido), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, revestido), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, revestido), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, revestido), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, revestido), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, revestido), SCALANCE X307-3 SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, puertos en la parte frontal), SCALANCE XR324-12M (230V, puertos en la parte delantera), SCALANCE XR324-12M (230V, puertos en la parte trasera), SCALANCE XR324-12M (230V, puertos en la parte trasera), SCALANCE XR324-12M (24V, puertos en la parte delantera), SCALANCE XR324-12M (24V, puertos en la parte delantera), SCALANCE XR324-12M (24V, puertos en la parte trasera), SCALANCE XR324-12M (24V, puertos en la parte trasera), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte trasera), SCALANCE XR324-4M PoE (230V, puertos en la parte delantera), SCALANCE XR324-4M PoE (230V, puertos en la parte trasera), SCALANCE XR324-4M PoE (24V, puertos en la parte delantera), SCALANCE XR324-4M PoE (24V, puertos en la parte trasera), SCALANCE XR324-4M PoE TS (24V, puertos en la parte delantera), SIPLUS NET SCALANCE X308-2. El servidor web integrado del dispositivo afectado podr\\u00eda permitir a atacantes remotos llevar a cabo acciones con los permisos de un usuario v\\u00edctima, siempre que \\u00e9ste tenga una sesi\\u00f3n activa y sea inducido a lanzar la petici\\u00f3n maliciosa\"}]", "id": "CVE-2022-25754", "lastModified": "2024-11-21T06:52:56.263", "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}", "published": "2022-04-12T09:15:14.747", "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Mitigation\", \"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Patch\", \"Vendor Advisory\"]}]", "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-352\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-352\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2022-25754\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-04-12T09:15:14.747\",\"lastModified\":\"2024-11-21T06:52:56.263\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, revestido), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, revestido), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, revestido), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, revestido), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, revestido), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, revestido), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, revestido), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, revestido), SCALANCE X307-3 SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, puertos en la parte frontal), SCALANCE XR324-12M (230V, puertos en la parte delantera), SCALANCE XR324-12M (230V, puertos en la parte trasera), SCALANCE XR324-12M (230V, puertos en la parte trasera), SCALANCE XR324-12M (24V, puertos en la parte delantera), SCALANCE XR324-12M (24V, puertos en la parte delantera), SCALANCE XR324-12M (24V, puertos en la parte trasera), SCALANCE XR324-12M (24V, puertos en la parte trasera), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte trasera), SCALANCE XR324-4M PoE (230V, puertos en la parte delantera), SCALANCE XR324-4M PoE (230V, puertos en la parte trasera), SCALANCE XR324-4M PoE (24V, puertos en la parte delantera), SCALANCE XR324-4M PoE (24V, puertos en la parte trasera), SCALANCE XR324-4M PoE TS (24V, puertos en la parte delantera), SIPLUS NET SCALANCE X308-2. El servidor web integrado del dispositivo afectado podr\u00eda permitir a atacantes remotos llevar a cabo acciones con los permisos de un usuario v\u00edctima, siempre que \u00e9ste tenga una sesi\u00f3n activa y sea inducido a lanzar la petici\u00f3n maliciosa\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"7FB6F150-2662-44AE-8DC1-0B0A426E8352\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8E97B3B-1808-45D2-97B7-CF31CA6E7A60\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"E9F4071F-1AE2-4FAD-A8CB-1619552101A3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0087A1C6-AA76-4FD6-BAA1-D3190D2A0116\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"4B78CFDF-1B15-4A4B-99D4-8CC5E1867BD1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"880CF41B-B25D-4744-8E8B-C4B131932B1B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"CCB1094D-3F8A-4331-ABB9-46B73F7E008F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"804EE08B-75A1-4CF6-9C30-8CF0CDC39658\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"EE21803A-A5CA-482A-ABD2-C9A547831BF6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"EEBFBB10-35E0-46BB-A937-E9A933C4D5BC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7737F0C2-43FC-4330-88F2-9B08BA5B35D7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"4C91F6DD-A74C-4310-88AB-63A39D0208BE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6CCED3E4-38EF-4645-B25C-4F2C3D4E091C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"6B5513D8-59DD-4EE1-B2E8-F800D1DA7BC5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FE1909FA-C8C6-46BE-83C6-2635D36FE69B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"A11DE626-D744-49A7-93C4-FE2C2AF5245F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6DDBD94D-5312-4A54-AF76-D9DF791C0292\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x308-2lh\\\\+_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"DC259CD1-5C79-4491-B375-7A69116F2747\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x308-2lh\\\\+:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85153EED-C677-495D-A6BB-72365DE1ED3F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"79918934-7B0B-4032-972E-2347CD33029D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AC54911E-C432-48FA-9551-9644422FFE14\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"00FBD442-84AA-48F3-8AD1-5767FFB2FC3F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3E22C57C-2BD6-4C39-93D2-5D81A58EA6F0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"E72D4503-5AAE-4C6F-BAE9-FA51701191B1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DFCCB68C-A58D-4543-A11F-721B01FFBBA4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"CA2333C8-E9C7-43D8-9EAA-A88ECAAB4236\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7FE3716E-1C0A-4B72-809A-8318E5853FB1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"7EECD381-262F-4C47-90E1-7B44092C74BD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8FB34E83-83A3-45C3-B040-D8910971D439\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"36C40232-5696-44CC-B38F-5331A745C760\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC54880F-CBF4-4772-A4FB-B07D97287D44\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"2F1969E4-CFD6-4AC7-956E-374967F5C406\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B2D400F5-AD80-4536-A99D-793E1560757B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"3ACB931D-C484-42F4-9912-24B44FE97017\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0C632B90-EB11-4A4C-8128-DABBE044B9AF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"B1EFA152-D29B-4116-A3D2-ACF7A025E053\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F952542-6B79-4681-A236-15C188AAEB1E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"935CD21D-0471-4D1F-AF81-B1F996A9EFAB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"664D9C76-BC13-4874-939C-A8211DA33903\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"E2C0F1FB-8B5E-448C-A304-FDDCB3DFCDD4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4834A67B-7B0B-4F88-BBFB-25667FD68EC5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"3E0E1F54-D9EA-4AFB-80EF-0A585EC3C641\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"36C9AE74-4683-4ED0-A605-3A6B065C230E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"DC03DF92-C7A1-4232-AFDF-04B2B50666DB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4356417E-B4CB-45B0-B395-CE9D423FAB44\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1.4\",\"matchCriteriaId\":\"25103533-B9BC-4553-B195-AF5CACAB713B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C48C944-324B-4390-B9D1-3D0FC3DD5BFD\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}" } }
ICSA-22-104-09
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael Messner", "Abian Blome" ], "organization": "Siemens Energy", "summary": "coordinating the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to reboot, cause denial-of-service conditions, and impact the system by other means through buffer overflow vulnerabilities.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-836527: Multiple Vulnerabilities in SCALANCE X-300 Switch Family Devices - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-836527.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-104-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-104-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-104-09 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-836527: Multiple Vulnerabilities in SCALANCE X-300 Switch Family Devices - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" }, { "category": "external", "summary": "SSA-836527: Multiple Vulnerabilities in SCALANCE X-300 Switch Family Devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-836527.txt" } ], "title": "Siemens SCALANCE X-300 Switches", "tracking": { "current_release_date": "2022-04-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-104-09", "initial_release_date": "2022-04-14T00:00:00.000000Z", "revision_history": [ { "date": "2022-04-14T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-104-09 Siemens SCALANCE X-300 Switches" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (2x 24V)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-2EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (2x 24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (2x 24V, coated)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-2GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (2x 24V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (2x 230V)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-4EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (2x 230V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (2x 230V, coated)", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-4GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (2x 230V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (24V)", "product_id": "CSAFPID-0005", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-1EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (24V, coated)", "product_id": "CSAFPID-0006", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-1GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (24V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (230V)", "product_id": "CSAFPID-0007", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-3EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (230V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (230V, coated)", "product_id": "CSAFPID-0008", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-3GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (230V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X304-2FE", "product_id": "CSAFPID-0009", "product_identification_helper": { "model_numbers": [ "6GK5304-2BD00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X304-2FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X306-1LD FE", "product_id": "CSAFPID-00010", "product_identification_helper": { "model_numbers": [ "6GK5306-1BF00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X306-1LD FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (2x 24V)", "product_id": "CSAFPID-00011", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-2EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (2x 24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (2x 24V, coated)", "product_id": "CSAFPID-00012", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-2GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (2x 24V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (2x 230V)", "product_id": "CSAFPID-00013", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-4EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (2x 230V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (2x 230V, coated)", "product_id": "CSAFPID-00014", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-4GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (2x 230V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (24V)", "product_id": "CSAFPID-00015", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-1EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (24V, coated)", "product_id": "CSAFPID-00016", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-1GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (24V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (230V)", "product_id": "CSAFPID-00017", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-3EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (230V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (230V, coated)", "product_id": "CSAFPID-00018", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-3GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (230V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-3", "product_id": "CSAFPID-00019", "product_identification_helper": { "model_numbers": [ "6GK5307-3BL00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-3" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-3", "product_id": "CSAFPID-00020", "product_identification_helper": { "model_numbers": [ "6GK5307-3BL10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-3" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-3LD", "product_id": "CSAFPID-00021", "product_identification_helper": { "model_numbers": [ "6GK5307-3BM00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-3LD" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-3LD", "product_id": "CSAFPID-00022", "product_identification_helper": { "model_numbers": [ "6GK5307-3BM10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-3LD" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2", "product_id": "CSAFPID-00023", "product_identification_helper": { "model_numbers": [ "6GK5308-2FL00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2", "product_id": "CSAFPID-00024", "product_identification_helper": { "model_numbers": [ "6GK5308-2FL10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LD", "product_id": "CSAFPID-00025", "product_identification_helper": { "model_numbers": [ "6GK5308-2FM00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LD" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LD", "product_id": "CSAFPID-00026", "product_identification_helper": { "model_numbers": [ "6GK5308-2FM10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LD" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LH", "product_id": "CSAFPID-00027", "product_identification_helper": { "model_numbers": [ "6GK5308-2FN00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LH" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LH", "product_id": "CSAFPID-00028", "product_identification_helper": { "model_numbers": [ "6GK5308-2FN10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LH" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LH+", "product_id": "CSAFPID-00029", "product_identification_helper": { "model_numbers": [ "6GK5308-2FP00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LH+" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LH+", "product_id": "CSAFPID-00030", "product_identification_helper": { "model_numbers": [ "6GK5308-2FP10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LH+" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M", "product_id": "CSAFPID-00031", "product_identification_helper": { "model_numbers": [ "6GK5308-2GG00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M", "product_id": "CSAFPID-00032", "product_identification_helper": { "model_numbers": [ "6GK5308-2GG10-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M PoE", "product_id": "CSAFPID-00033", "product_identification_helper": { "model_numbers": [ "6GK5308-2QG00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M PoE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M PoE", "product_id": "CSAFPID-00034", "product_identification_helper": { "model_numbers": [ "6GK5308-2QG10-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M PoE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M TS", "product_id": "CSAFPID-00035", "product_identification_helper": { "model_numbers": [ "6GK5308-2GG00-2CA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M TS" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M TS", "product_id": "CSAFPID-00036", "product_identification_helper": { "model_numbers": [ "6GK5308-2GG10-2CA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M TS" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X310", "product_id": "CSAFPID-00037", "product_identification_helper": { "model_numbers": [ "6GK5310-0FA00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X310" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X310", "product_id": "CSAFPID-00038", "product_identification_helper": { "model_numbers": [ "6GK5310-0FA10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X310" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X310FE", "product_id": "CSAFPID-00039", "product_identification_helper": { "model_numbers": [ "6GK5310-0BA00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X310FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X310FE", "product_id": "CSAFPID-00040", "product_identification_helper": { "model_numbers": [ "6GK5310-0BA10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X310FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X320-1 FE", "product_id": "CSAFPID-00041", "product_identification_helper": { "model_numbers": [ "6GK5320-1BD00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X320-1 FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X320-1-2LD FE", "product_id": "CSAFPID-00042", "product_identification_helper": { "model_numbers": [ "6GK5320-3BF00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X320-1-2LD FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X408-2", "product_id": "CSAFPID-00043", "product_identification_helper": { "model_numbers": [ "6GK5408-2FD00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE X408-2" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "product_id": "CSAFPID-00044", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-2ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "product_id": "CSAFPID-00045", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-2ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "product_id": "CSAFPID-00046", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-2JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "product_id": "CSAFPID-00047", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-2JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "product_id": "CSAFPID-00048", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-4ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "product_id": "CSAFPID-00049", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-4ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "product_id": "CSAFPID-00050", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-4JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "product_id": "CSAFPID-00051", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-4JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (24V, ports on front)", "product_id": "CSAFPID-00052", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-1ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (24V, ports on front)", "product_id": "CSAFPID-00053", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-1ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "product_id": "CSAFPID-00054", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-1JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "product_id": "CSAFPID-00055", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-1JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "product_id": "CSAFPID-00056", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-3ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "product_id": "CSAFPID-00057", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-3ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "product_id": "CSAFPID-00058", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-3JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "product_id": "CSAFPID-00059", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-3JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M PoE (24V, ports on front)", "product_id": "CSAFPID-00060", "product_identification_helper": { "model_numbers": [ "6GK5324-4QG00-1AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M PoE (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M PoE (24V, ports on rear)", "product_id": "CSAFPID-00061", "product_identification_helper": { "model_numbers": [ "6GK5324-4QG00-1HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M PoE (24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M PoE (230V, ports on front)", "product_id": "CSAFPID-00062", "product_identification_helper": { "model_numbers": [ "6GK5324-4QG00-3AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M PoE (230V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M PoE (230V, ports on rear)", "product_id": "CSAFPID-00063", "product_identification_helper": { "model_numbers": [ "6GK5324-4QG00-3HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M PoE (230V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "product_id": "CSAFPID-00064", "product_identification_helper": { "model_numbers": [ "6GK5324-4QG00-1CR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M PoE TS (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (24V, ports on front)", "product_id": "CSAFPID-00065", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG00-1AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (24V, ports on front)", "product_id": "CSAFPID-00066", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG10-1AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (24V, ports on rear)", "product_id": "CSAFPID-00067", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG00-1HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (24V, ports on rear)", "product_id": "CSAFPID-00068", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG10-1HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (230V, ports on front)", "product_id": "CSAFPID-00069", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG00-3AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (230V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (230V, ports on front)", "product_id": "CSAFPID-00070", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG10-3AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (230V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (230V, ports on rear)", "product_id": "CSAFPID-00071", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG00-3HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (230V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (230V, ports on rear)", "product_id": "CSAFPID-00072", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG10-3HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (230V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M TS (24V)", "product_id": "CSAFPID-00073", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG00-1CR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M TS (24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M TS (24V)", "product_id": "CSAFPID-00074", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG10-1CR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M TS (24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SIPLUS NET SCALANCE X308-2", "product_id": "CSAFPID-00075", "product_identification_helper": { "model_numbers": [ "6AG1308-2FL10-4AA3" ] } } } ], "category": "product_name", "name": "SIPLUS NET SCALANCE X308-2" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-25751", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25751.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25751" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25751" }, { "cve": "CVE-2022-25752", "cwe": { "id": "CWE-330", "name": "Use of Insufficiently Random Values" }, "notes": [ { "category": "summary", "text": "The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25752.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25752" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25752" }, { "cve": "CVE-2022-25753", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25753.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25753" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25753" }, { "cve": "CVE-2022-25754", "cwe": { "id": "CWE-352", "name": "Cross-Site Request Forgery (CSRF)" }, "notes": [ { "category": "summary", "text": "The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25754.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25754" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25754" }, { "cve": "CVE-2022-25755", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25755.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25755" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.6, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25755" }, { "cve": "CVE-2022-25756", "cwe": { "id": "CWE-80", "name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)" }, "notes": [ { "category": "summary", "text": "The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25756.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25756" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.9, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25756" }, { "cve": "CVE-2022-26334", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-26334.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-26334" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-26334" }, { "cve": "CVE-2022-26335", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-26335.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-26335" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-26335" }, { "cve": "CVE-2022-26380", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-26380.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-26380" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-26380" } ] }
icsa-22-104-09
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael Messner", "Abian Blome" ], "organization": "Siemens Energy", "summary": "coordinating the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to reboot, cause denial-of-service conditions, and impact the system by other means through buffer overflow vulnerabilities.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-836527: Multiple Vulnerabilities in SCALANCE X-300 Switch Family Devices - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-836527.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-104-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-104-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-104-09 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-836527: Multiple Vulnerabilities in SCALANCE X-300 Switch Family Devices - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" }, { "category": "external", "summary": "SSA-836527: Multiple Vulnerabilities in SCALANCE X-300 Switch Family Devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-836527.txt" } ], "title": "Siemens SCALANCE X-300 Switches", "tracking": { "current_release_date": "2022-04-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-104-09", "initial_release_date": "2022-04-14T00:00:00.000000Z", "revision_history": [ { "date": "2022-04-14T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-104-09 Siemens SCALANCE X-300 Switches" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (2x 24V)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-2EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (2x 24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (2x 24V, coated)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-2GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (2x 24V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (2x 230V)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-4EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (2x 230V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (2x 230V, coated)", "product_id": "CSAFPID-0004", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-4GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (2x 230V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (24V)", "product_id": "CSAFPID-0005", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-1EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (24V, coated)", "product_id": "CSAFPID-0006", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-1GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (24V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (230V)", "product_id": "CSAFPID-0007", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-3EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (230V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X302-7 EEC (230V, coated)", "product_id": "CSAFPID-0008", "product_identification_helper": { "model_numbers": [ "6GK5302-7GD00-3GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X302-7 EEC (230V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X304-2FE", "product_id": "CSAFPID-0009", "product_identification_helper": { "model_numbers": [ "6GK5304-2BD00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X304-2FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X306-1LD FE", "product_id": "CSAFPID-00010", "product_identification_helper": { "model_numbers": [ "6GK5306-1BF00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X306-1LD FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (2x 24V)", "product_id": "CSAFPID-00011", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-2EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (2x 24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (2x 24V, coated)", "product_id": "CSAFPID-00012", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-2GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (2x 24V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (2x 230V)", "product_id": "CSAFPID-00013", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-4EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (2x 230V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (2x 230V, coated)", "product_id": "CSAFPID-00014", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-4GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (2x 230V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (24V)", "product_id": "CSAFPID-00015", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-1EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (24V, coated)", "product_id": "CSAFPID-00016", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-1GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (24V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (230V)", "product_id": "CSAFPID-00017", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-3EA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (230V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-2 EEC (230V, coated)", "product_id": "CSAFPID-00018", "product_identification_helper": { "model_numbers": [ "6GK5307-2FD00-3GA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-2 EEC (230V, coated)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-3", "product_id": "CSAFPID-00019", "product_identification_helper": { "model_numbers": [ "6GK5307-3BL00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-3" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-3", "product_id": "CSAFPID-00020", "product_identification_helper": { "model_numbers": [ "6GK5307-3BL10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-3" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-3LD", "product_id": "CSAFPID-00021", "product_identification_helper": { "model_numbers": [ "6GK5307-3BM00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-3LD" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X307-3LD", "product_id": "CSAFPID-00022", "product_identification_helper": { "model_numbers": [ "6GK5307-3BM10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X307-3LD" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2", "product_id": "CSAFPID-00023", "product_identification_helper": { "model_numbers": [ "6GK5308-2FL00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2", "product_id": "CSAFPID-00024", "product_identification_helper": { "model_numbers": [ "6GK5308-2FL10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LD", "product_id": "CSAFPID-00025", "product_identification_helper": { "model_numbers": [ "6GK5308-2FM00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LD" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LD", "product_id": "CSAFPID-00026", "product_identification_helper": { "model_numbers": [ "6GK5308-2FM10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LD" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LH", "product_id": "CSAFPID-00027", "product_identification_helper": { "model_numbers": [ "6GK5308-2FN00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LH" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LH", "product_id": "CSAFPID-00028", "product_identification_helper": { "model_numbers": [ "6GK5308-2FN10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LH" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LH+", "product_id": "CSAFPID-00029", "product_identification_helper": { "model_numbers": [ "6GK5308-2FP00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LH+" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2LH+", "product_id": "CSAFPID-00030", "product_identification_helper": { "model_numbers": [ "6GK5308-2FP10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2LH+" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M", "product_id": "CSAFPID-00031", "product_identification_helper": { "model_numbers": [ "6GK5308-2GG00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M", "product_id": "CSAFPID-00032", "product_identification_helper": { "model_numbers": [ "6GK5308-2GG10-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M PoE", "product_id": "CSAFPID-00033", "product_identification_helper": { "model_numbers": [ "6GK5308-2QG00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M PoE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M PoE", "product_id": "CSAFPID-00034", "product_identification_helper": { "model_numbers": [ "6GK5308-2QG10-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M PoE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M TS", "product_id": "CSAFPID-00035", "product_identification_helper": { "model_numbers": [ "6GK5308-2GG00-2CA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M TS" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X308-2M TS", "product_id": "CSAFPID-00036", "product_identification_helper": { "model_numbers": [ "6GK5308-2GG10-2CA2" ] } } } ], "category": "product_name", "name": "SCALANCE X308-2M TS" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X310", "product_id": "CSAFPID-00037", "product_identification_helper": { "model_numbers": [ "6GK5310-0FA00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X310" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X310", "product_id": "CSAFPID-00038", "product_identification_helper": { "model_numbers": [ "6GK5310-0FA10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X310" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X310FE", "product_id": "CSAFPID-00039", "product_identification_helper": { "model_numbers": [ "6GK5310-0BA00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X310FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X310FE", "product_id": "CSAFPID-00040", "product_identification_helper": { "model_numbers": [ "6GK5310-0BA10-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X310FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X320-1 FE", "product_id": "CSAFPID-00041", "product_identification_helper": { "model_numbers": [ "6GK5320-1BD00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X320-1 FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X320-1-2LD FE", "product_id": "CSAFPID-00042", "product_identification_helper": { "model_numbers": [ "6GK5320-3BF00-2AA3" ] } } } ], "category": "product_name", "name": "SCALANCE X320-1-2LD FE" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE X408-2", "product_id": "CSAFPID-00043", "product_identification_helper": { "model_numbers": [ "6GK5408-2FD00-2AA2" ] } } } ], "category": "product_name", "name": "SCALANCE X408-2" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "product_id": "CSAFPID-00044", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-2ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "product_id": "CSAFPID-00045", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-2ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "product_id": "CSAFPID-00046", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-2JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "product_id": "CSAFPID-00047", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-2JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "product_id": "CSAFPID-00048", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-4ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "product_id": "CSAFPID-00049", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-4ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "product_id": "CSAFPID-00050", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-4JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "product_id": "CSAFPID-00051", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-4JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (24V, ports on front)", "product_id": "CSAFPID-00052", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-1ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (24V, ports on front)", "product_id": "CSAFPID-00053", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-1ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "product_id": "CSAFPID-00054", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-1JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "product_id": "CSAFPID-00055", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-1JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "product_id": "CSAFPID-00056", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-3ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "product_id": "CSAFPID-00057", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-3ER2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "product_id": "CSAFPID-00058", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG00-3JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "product_id": "CSAFPID-00059", "product_identification_helper": { "model_numbers": [ "6GK5324-4GG10-3JR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M PoE (24V, ports on front)", "product_id": "CSAFPID-00060", "product_identification_helper": { "model_numbers": [ "6GK5324-4QG00-1AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M PoE (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M PoE (24V, ports on rear)", "product_id": "CSAFPID-00061", "product_identification_helper": { "model_numbers": [ "6GK5324-4QG00-1HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M PoE (24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M PoE (230V, ports on front)", "product_id": "CSAFPID-00062", "product_identification_helper": { "model_numbers": [ "6GK5324-4QG00-3AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M PoE (230V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M PoE (230V, ports on rear)", "product_id": "CSAFPID-00063", "product_identification_helper": { "model_numbers": [ "6GK5324-4QG00-3HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M PoE (230V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "product_id": "CSAFPID-00064", "product_identification_helper": { "model_numbers": [ "6GK5324-4QG00-1CR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-4M PoE TS (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (24V, ports on front)", "product_id": "CSAFPID-00065", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG00-1AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (24V, ports on front)", "product_id": "CSAFPID-00066", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG10-1AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (24V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (24V, ports on rear)", "product_id": "CSAFPID-00067", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG00-1HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (24V, ports on rear)", "product_id": "CSAFPID-00068", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG10-1HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (24V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (230V, ports on front)", "product_id": "CSAFPID-00069", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG00-3AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (230V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (230V, ports on front)", "product_id": "CSAFPID-00070", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG10-3AR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (230V, ports on front)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (230V, ports on rear)", "product_id": "CSAFPID-00071", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG00-3HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (230V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M (230V, ports on rear)", "product_id": "CSAFPID-00072", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG10-3HR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M (230V, ports on rear)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M TS (24V)", "product_id": "CSAFPID-00073", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG00-1CR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M TS (24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SCALANCE XR324-12M TS (24V)", "product_id": "CSAFPID-00074", "product_identification_helper": { "model_numbers": [ "6GK5324-0GG10-1CR2" ] } } } ], "category": "product_name", "name": "SCALANCE XR324-12M TS (24V)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V4.1.4", "product": { "name": "SIPLUS NET SCALANCE X308-2", "product_id": "CSAFPID-00075", "product_identification_helper": { "model_numbers": [ "6AG1308-2FL10-4AA3" ] } } } ], "category": "product_name", "name": "SIPLUS NET SCALANCE X308-2" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-25751", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25751 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25751.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25751" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25751" }, { "cve": "CVE-2022-25752", "cwe": { "id": "CWE-330", "name": "Use of Insufficiently Random Values" }, "notes": [ { "category": "summary", "text": "The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25752 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25752.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25752" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25752" }, { "cve": "CVE-2022-25753", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25753 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25753.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25753" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25753" }, { "cve": "CVE-2022-25754", "cwe": { "id": "CWE-352", "name": "Cross-Site Request Forgery (CSRF)" }, "notes": [ { "category": "summary", "text": "The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25754 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25754.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25754" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25754" }, { "cve": "CVE-2022-25755", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25755 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25755.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25755" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 2.6, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25755" }, { "cve": "CVE-2022-25756", "cwe": { "id": "CWE-80", "name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)" }, "notes": [ { "category": "summary", "text": "The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-25756 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-25756.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-25756" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.9, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-25756" }, { "cve": "CVE-2022-26334", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26334 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-26334.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-26334" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-26334" }, { "cve": "CVE-2022-26335", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26335 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-26335.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-26335" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-26335" }, { "cve": "CVE-2022-26380", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, "references": [ { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X302-7 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X304-2FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X306-1LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (2x 24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (2x 24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (2x 230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (2x 230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (24V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (230V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-2 EEC (230V, coated)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-3", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X307-3LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LD", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LH", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2LH+", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M PoE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X308-2M TS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X310", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X310FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X320-1 FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X320-1-2LD FE", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE X408-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M PoE (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M PoE (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M PoE (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M PoE (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-4M PoE TS (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (24V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (24V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (230V, ports on front)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M (230V, ports on rear)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SCALANCE XR324-12M TS (24V)", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 - SIPLUS NET SCALANCE X308-2", "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "summary": "CVE-2022-26380 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-26380.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-26380" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V4.1.4 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109808359/" }, { "category": "workaround", "details": "Restrict access to the affected systems, especially to ports 22/tcp, 161/udp, and 443/tcp to trusted IP addresses only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Disable SNMP service, if possible", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "workaround", "details": "Deactivate the webserver if not required, and if deactivation is supported by the product", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019", "CSAFPID-00020", "CSAFPID-00021", "CSAFPID-00022", "CSAFPID-00023", "CSAFPID-00024", "CSAFPID-00025", "CSAFPID-00026", "CSAFPID-00027", "CSAFPID-00028", "CSAFPID-00029", "CSAFPID-00030", "CSAFPID-00031", "CSAFPID-00032", "CSAFPID-00033", "CSAFPID-00034", "CSAFPID-00035", "CSAFPID-00036", "CSAFPID-00037", "CSAFPID-00038", "CSAFPID-00039", "CSAFPID-00040", "CSAFPID-00041", "CSAFPID-00042", "CSAFPID-00043", "CSAFPID-00044", "CSAFPID-00045", "CSAFPID-00046", "CSAFPID-00047", "CSAFPID-00048", "CSAFPID-00049", "CSAFPID-00050", "CSAFPID-00051", "CSAFPID-00052", "CSAFPID-00053", "CSAFPID-00054", "CSAFPID-00055", "CSAFPID-00056", "CSAFPID-00057", "CSAFPID-00058", "CSAFPID-00059", "CSAFPID-00060", "CSAFPID-00061", "CSAFPID-00062", "CSAFPID-00063", "CSAFPID-00064", "CSAFPID-00065", "CSAFPID-00066", "CSAFPID-00067", "CSAFPID-00068", "CSAFPID-00069", "CSAFPID-00070", "CSAFPID-00071", "CSAFPID-00072", "CSAFPID-00073", "CSAFPID-00074", "CSAFPID-00075" ] } ], "title": "CVE-2022-26380" } ] }
cve-2022-25754
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf | Mitigation, Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf | Mitigation, Patch, Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
siemens | scalance_x302-7eec_firmware | * | |
siemens | scalance_x302-7eec | - | |
siemens | scalance_x304-2fe_firmware | * | |
siemens | scalance_x304-2fe | - | |
siemens | scalance_x306-1ldfe_firmware | * | |
siemens | scalance_x306-1ldfe | - | |
siemens | scalance_x307-2eec_firmware | * | |
siemens | scalance_x307-2eec | - | |
siemens | scalance_x307-3_firmware | * | |
siemens | scalance_x307-3 | - | |
siemens | scalance_x307-3ld_firmware | * | |
siemens | scalance_x307-3ld | - | |
siemens | scalance_x308-2_firmware | * | |
siemens | scalance_x308-2 | - | |
siemens | scalance_x308-2ld_firmware | * | |
siemens | scalance_x308-2ld | - | |
siemens | scalance_x308-2lh_firmware | * | |
siemens | scalance_x308-2lh | - | |
siemens | scalance_x308-2lh\+_firmware | * | |
siemens | scalance_x308-2lh\+ | - | |
siemens | scalance_x308-2m_firmware | * | |
siemens | scalance_x308-2m | - | |
siemens | scalance_x308-2m_poe_firmware | - | |
siemens | scalance_x308-2m_poe | - | |
siemens | scalance_x308-2m_ts_firmware | * | |
siemens | scalance_x308-2m_ts | - | |
siemens | scalance_x310_firmware | * | |
siemens | scalance_x310 | - | |
siemens | scalance_x310fe_firmware | * | |
siemens | scalance_x310fe | - | |
siemens | scalance_x320-1fe_firmware | * | |
siemens | scalance_x320-1fe | - | |
siemens | scalance_x320-1-2ldfe_firmware | * | |
siemens | scalance_x320-1-2ldfe | - | |
siemens | scalance_x408-2_firmware | * | |
siemens | scalance_x408-2 | - | |
siemens | scalance_xr324-4m_eec_firmware | * | |
siemens | scalance_xr324-4m_eec | - | |
siemens | scalance_xr324-4m_poe_firmware | * | |
siemens | scalance_xr324-4m_poe | - | |
siemens | scalance_xr324-4m_poe_ts_firmware | * | |
siemens | scalance_xr324-4m_poe_ts | - | |
siemens | scalance_xr324-12m_firmware | * | |
siemens | scalance_xr324-12m | - | |
siemens | scalance_xr324-12m_ts_firmware | * | |
siemens | scalance_xr324-12m_ts | - | |
siemens | siplus_net_scalance_x308-2_firmware | * | |
siemens | siplus_net_scalance_x308-2 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FB6F150-2662-44AE-8DC1-0B0A426E8352", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*", "matchCriteriaId": "C8E97B3B-1808-45D2-97B7-CF31CA6E7A60", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9F4071F-1AE2-4FAD-A8CB-1619552101A3", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*", "matchCriteriaId": "0087A1C6-AA76-4FD6-BAA1-D3190D2A0116", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B78CFDF-1B15-4A4B-99D4-8CC5E1867BD1", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*", "matchCriteriaId": "880CF41B-B25D-4744-8E8B-C4B131932B1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CCB1094D-3F8A-4331-ABB9-46B73F7E008F", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*", "matchCriteriaId": "804EE08B-75A1-4CF6-9C30-8CF0CDC39658", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE21803A-A5CA-482A-ABD2-C9A547831BF6", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*", "matchCriteriaId": "55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEBFBB10-35E0-46BB-A937-E9A933C4D5BC", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "7737F0C2-43FC-4330-88F2-9B08BA5B35D7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C91F6DD-A74C-4310-88AB-63A39D0208BE", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CCED3E4-38EF-4645-B25C-4F2C3D4E091C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B5513D8-59DD-4EE1-B2E8-F800D1DA7BC5", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE1909FA-C8C6-46BE-83C6-2635D36FE69B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A11DE626-D744-49A7-93C4-FE2C2AF5245F", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DDBD94D-5312-4A54-AF76-D9DF791C0292", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DC259CD1-5C79-4491-B375-7A69116F2747", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*", "matchCriteriaId": "85153EED-C677-495D-A6BB-72365DE1ED3F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79918934-7B0B-4032-972E-2347CD33029D", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*", "matchCriteriaId": "AC54911E-C432-48FA-9551-9644422FFE14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "00FBD442-84AA-48F3-8AD1-5767FFB2FC3F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E22C57C-2BD6-4C39-93D2-5D81A58EA6F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E72D4503-5AAE-4C6F-BAE9-FA51701191B1", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFCCB68C-A58D-4543-A11F-721B01FFBBA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA2333C8-E9C7-43D8-9EAA-A88ECAAB4236", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*", "matchCriteriaId": "7FE3716E-1C0A-4B72-809A-8318E5853FB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7EECD381-262F-4C47-90E1-7B44092C74BD", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*", "matchCriteriaId": "8FB34E83-83A3-45C3-B040-D8910971D439", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "36C40232-5696-44CC-B38F-5331A745C760", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC54880F-CBF4-4772-A4FB-B07D97287D44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2F1969E4-CFD6-4AC7-956E-374967F5C406", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2D400F5-AD80-4536-A99D-793E1560757B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3ACB931D-C484-42F4-9912-24B44FE97017", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "0C632B90-EB11-4A4C-8128-DABBE044B9AF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1EFA152-D29B-4116-A3D2-ACF7A025E053", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F952542-6B79-4681-A236-15C188AAEB1E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "935CD21D-0471-4D1F-AF81-B1F996A9EFAB", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*", "matchCriteriaId": "664D9C76-BC13-4874-939C-A8211DA33903", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2C0F1FB-8B5E-448C-A304-FDDCB3DFCDD4", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "4834A67B-7B0B-4F88-BBFB-25667FD68EC5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E0E1F54-D9EA-4AFB-80EF-0A585EC3C641", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*", "matchCriteriaId": "36C9AE74-4683-4ED0-A605-3A6B065C230E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DC03DF92-C7A1-4232-AFDF-04B2B50666DB", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "4356417E-B4CB-45B0-B395-CE9D423FAB44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "25103533-B9BC-4553-B195-AF5CACAB713B", "versionEndExcluding": "4.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "9C48C944-324B-4390-B9D1-3D0FC3DD5BFD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, revestido), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, revestido), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, revestido), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, revestido), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, revestido), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, revestido), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, revestido), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, revestido), SCALANCE X307-3 SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, puertos en la parte frontal), SCALANCE XR324-12M (230V, puertos en la parte delantera), SCALANCE XR324-12M (230V, puertos en la parte trasera), SCALANCE XR324-12M (230V, puertos en la parte trasera), SCALANCE XR324-12M (24V, puertos en la parte delantera), SCALANCE XR324-12M (24V, puertos en la parte delantera), SCALANCE XR324-12M (24V, puertos en la parte trasera), SCALANCE XR324-12M (24V, puertos en la parte trasera), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte trasera), SCALANCE XR324-4M PoE (230V, puertos en la parte delantera), SCALANCE XR324-4M PoE (230V, puertos en la parte trasera), SCALANCE XR324-4M PoE (24V, puertos en la parte delantera), SCALANCE XR324-4M PoE (24V, puertos en la parte trasera), SCALANCE XR324-4M PoE TS (24V, puertos en la parte delantera), SIPLUS NET SCALANCE X308-2. El servidor web integrado del dispositivo afectado podr\u00eda permitir a atacantes remotos llevar a cabo acciones con los permisos de un usuario v\u00edctima, siempre que \u00e9ste tenga una sesi\u00f3n activa y sea inducido a lanzar la petici\u00f3n maliciosa" } ], "id": "CVE-2022-25754", "lastModified": "2024-11-21T06:52:56.263", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-12T09:15:14.747", "references": [ { "source": "productcert@siemens.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
ghsa-pm3p-vw5f-jpj5
Vulnerability from github
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.
{ "affected": [], "aliases": [ "CVE-2022-25754" ], "database_specific": { "cwe_ids": [ "CWE-352" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-04-12T09:15:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.", "id": "GHSA-pm3p-vw5f-jpj5", "modified": "2022-04-20T00:00:52Z", "published": "2022-04-13T00:00:32Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-25754" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
var-202204-0495
Vulnerability from variot
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request. plural SCALANCE The product contains a cross-site request forgery vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0495", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance xr324-4m eec", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance xr324-4m poe", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance xr324-4m poe ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance xr324-12m", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance xr324-12m ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x308-2m", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x307-3ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x304-2fe", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x310fe", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x308-2m ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x308-2ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x308-2lh", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x320-1fe", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x307-3", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x302-7eec", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x320-1-2ldfe", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "siplus net scalance x308-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x408-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x308-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x306-1ldfe", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x308-2m poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance x308-2lh\\+", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x310", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x307-2eec", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance x304-2fe", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x307-3ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x307-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x308-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x307-2eec", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x308-2ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x308-2lh+", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x308-2lh", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x306-1ldfe", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x302-7eec", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance fe", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x320-1\u003c4.1.4" }, { "model": "scalance x320-1-2ld fe", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x408-2\u003c4.1.4" }, { "model": "siplus net scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x308-2\u003c4.1.4" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x307-3\u003c4.1.4" }, { "model": "scalance eec", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x307-2\u003c4.1.4" }, { "model": "scalance x306-1ld fe", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance eec", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x302-7\u003c4.1.4" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x310\u003c4.1.4" }, { "model": "scalance x308-2m poe", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "4.1.4" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x308-2\u003c4.1.4" }, { "model": "scalance x308-2lh+", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "4.1.4" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-28483" }, { "db": "JVNDB", "id": "JVNDB-2022-001595" }, { "db": "NVD", "id": "CVE-2022-25754" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-25754" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Michael Messner and Abian Blome of Siemens Energy coordinated the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-3139" } ], "trust": 0.6 }, "cve": "CVE-2022-25754", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2022-25754", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "CNVD-2022-28483", "impactScore": 9.2, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:N/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-25754", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-25754", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2022-28483", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202204-3139", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2022-25754", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-28483" }, { "db": "VULMON", "id": "CVE-2022-25754" }, { "db": "JVNDB", "id": "JVNDB-2022-001595" }, { "db": "NVD", "id": "CVE-2022-25754" }, { "db": "CNNVD", "id": "CNNVD-202204-3139" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request. plural SCALANCE The product contains a cross-site request forgery vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions", "sources": [ { "db": "NVD", "id": "CVE-2022-25754" }, { "db": "JVNDB", "id": "JVNDB-2022-001595" }, { "db": "CNVD", "id": "CNVD-2022-28483" }, { "db": "VULMON", "id": "CVE-2022-25754" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-25754", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-836527", "trust": 2.3 }, { "db": "ICS CERT", "id": "ICSA-22-104-09", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU91165555", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-001595", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-28483", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202204-3139", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-25754", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-28483" }, { "db": "VULMON", "id": "CVE-2022-25754" }, { "db": "JVNDB", "id": "JVNDB-2022-001595" }, { "db": "NVD", "id": "CVE-2022-25754" }, { "db": "CNNVD", "id": "CNNVD-202204-3139" } ] }, "id": "VAR-202204-0495", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-28483" } ], "trust": 1.2919426426666667 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-28483" } ] }, "last_update_date": "2023-12-18T11:56:14.715000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-836527", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" }, { "title": "Patch for Siemens SCALANCE X-300 Switch Family Devices Cross-Site Request Forgery Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/329316" }, { "title": "Multiple Siemens Repair measures for product cross-site request forgery vulnerability", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=190129" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-28483" }, { "db": "JVNDB", "id": "JVNDB-2022-001595" }, { "db": "CNNVD", "id": "CNNVD-202204-3139" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-352", "trust": 1.0 }, { "problemtype": "Cross-site request forgery (CWE-352) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-001595" }, { "db": "NVD", "id": "CVE-2022-25754" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" }, { "trust": 0.9, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-09" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91165555/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25754" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-25754/" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-09" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/352.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-28483" }, { "db": "VULMON", "id": "CVE-2022-25754" }, { "db": "JVNDB", "id": "JVNDB-2022-001595" }, { "db": "NVD", "id": "CVE-2022-25754" }, { "db": "CNNVD", "id": "CNNVD-202204-3139" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-28483" }, { "db": "VULMON", "id": "CVE-2022-25754" }, { "db": "JVNDB", "id": "JVNDB-2022-001595" }, { "db": "NVD", "id": "CVE-2022-25754" }, { "db": "CNNVD", "id": "CNNVD-202204-3139" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-13T00:00:00", "db": "CNVD", "id": "CNVD-2022-28483" }, { "date": "2022-04-12T00:00:00", "db": "VULMON", "id": "CVE-2022-25754" }, { "date": "2022-04-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-001595" }, { "date": "2022-04-12T09:15:14.747000", "db": "NVD", "id": "CVE-2022-25754" }, { "date": "2022-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202204-3139" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-13T00:00:00", "db": "CNVD", "id": "CNVD-2022-28483" }, { "date": "2022-04-19T00:00:00", "db": "VULMON", "id": "CVE-2022-25754" }, { "date": "2022-04-26T09:00:00", "db": "JVNDB", "id": "JVNDB-2022-001595" }, { "date": "2022-04-19T18:09:34.047000", "db": "NVD", "id": "CVE-2022-25754" }, { "date": "2022-04-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202204-3139" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-3139" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0SCALANCE\u00a0 Cross-site request forgery vulnerability in product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-001595" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "cross-site request forgery", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-3139" } ], "trust": 0.6 } }
gsd-2022-25754
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-25754", "description": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.", "id": "GSD-2022-25754" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-25754" ], "details": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.", "id": "GSD-2022-25754", "modified": "2023-12-13T01:19:27.464665Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-25754", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X302-7 EEC (230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X304-2FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X306-1LD FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-3", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-3", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-3LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-3LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LH", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LH", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LH+", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LH+", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M PoE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M PoE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M TS", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M TS", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X310", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X310", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X310FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X310FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X320-1 FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X320-1-2LD FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X408-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M TS (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M TS (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SIPLUS NET SCALANCE X308-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-352: Cross-Site Request Forgery (CSRF)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-25754" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-352" } ] } ] }, "references": { "reference_data": [ { "name": "N/A", "refsource": "CONFIRM", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } }, "lastModifiedDate": "2022-04-19T18:09Z", "publishedDate": "2022-04-12T09:15Z" } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.