cve-2022-28199
Vulnerability from cvelistv5
Published
2022-09-01 16:20
Modified
2024-08-03 05:48
Summary
NVIDIA’s distribution of the Data Plane Development Kit (MLNX_DPDK) contains a vulnerability in the network stack, where error recovery is not handled properly, which can allow a remote attacker to cause denial of service and some impact to data integrity and confidentiality.
Impacted products
NVIDIANVIDIA FLARE
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:48:37.435Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5389"
          },
          {
            "name": "[oss-security] 20220906 Re: CVE-2022-28199: DPDK mlx5 driver error recovery handling vulnerability",
            "tags": [
              "mailing-list",
              "x_refsource_MLIST",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2022/09/06/2"
          },
          {
            "name": "20220907 Vulnerability in NVIDIA Data Plane Development Kit Affecting Cisco Products: August 2022",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-mlx5-jbPCrqD8"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NVIDIA FLARE",
          "vendor": "NVIDIA",
          "versions": [
            {
              "status": "affected",
              "version": "mlnx_dpdk_19.11_1.*.* through mlnx_dpdk_20.11_1.0.0-4.*.*"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "NVIDIA\u2019s distribution of the Data Plane Development Kit (MLNX_DPDK) contains a vulnerability in the network stack, where error recovery is not handled properly, which can allow a remote attacker to cause denial of service and some impact to data integrity and confidentiality."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-07T17:06:13",
        "orgId": "9576f279-3576-44b5-a4af-b9a8644b2de6",
        "shortName": "nvidia"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5389"
        },
        {
          "name": "[oss-security] 20220906 Re: CVE-2022-28199: DPDK mlx5 driver error recovery handling vulnerability",
          "tags": [
            "mailing-list",
            "x_refsource_MLIST"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2022/09/06/2"
        },
        {
          "name": "20220907 Vulnerability in NVIDIA Data Plane Development Kit Affecting Cisco Products: August 2022",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-mlx5-jbPCrqD8"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@nvidia.com",
          "ID": "CVE-2022-28199",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NVIDIA FLARE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "mlnx_dpdk_19.11_1.*.* through mlnx_dpdk_20.11_1.0.0-4.*.*"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NVIDIA"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NVIDIA\u2019s distribution of the Data Plane Development Kit (MLNX_DPDK) contains a vulnerability in the network stack, where error recovery is not handled properly, which can allow a remote attacker to cause denial of service and some impact to data integrity and confidentiality."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-1284: Improper Validation of Specified Quantity in Input"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5389",
              "refsource": "MISC",
              "url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5389"
            },
            {
              "name": "[oss-security] 20220906 Re: CVE-2022-28199: DPDK mlx5 driver error recovery handling vulnerability",
              "refsource": "MLIST",
              "url": "http://www.openwall.com/lists/oss-security/2022/09/06/2"
            },
            {
              "name": "20220907 Vulnerability in NVIDIA Data Plane Development Kit Affecting Cisco Products: August 2022",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-mlx5-jbPCrqD8"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9576f279-3576-44b5-a4af-b9a8644b2de6",
    "assignerShortName": "nvidia",
    "cveId": "CVE-2022-28199",
    "datePublished": "2022-09-01T16:20:10",
    "dateReserved": "2022-03-30T00:00:00",
    "dateUpdated": "2024-08-03T05:48:37.435Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-28199\",\"sourceIdentifier\":\"psirt@nvidia.com\",\"published\":\"2022-09-01T17:15:08.077\",\"lastModified\":\"2022-09-07T18:15:08.713\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"NVIDIA\u2019s distribution of the Data Plane Development Kit (MLNX_DPDK) contains a vulnerability in the network stack, where error recovery is not handled properly, which can allow a remote attacker to cause denial of service and some impact to data integrity and confidentiality.\"},{\"lang\":\"es\",\"value\":\"La distribuci\u00f3n de NVIDIA del kit de desarrollo del plano de datos (MLNX_DPDK) contiene una vulnerabilidad en la pila de red, donde la recuperaci\u00f3n de errores no es manejada apropiadamente, lo que puede permitir a un atacante remoto causar una denegaci\u00f3n de servicio y alg\u00fan impacto en la integridad y confidencialidad de los datos\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@nvidia.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":4.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"psirt@nvidia.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1284\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:nvidia:data_plane_development_kit:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"19.11_1.0.0\",\"versionEndExcluding\":\"20.11_5.0.0\",\"matchCriteriaId\":\"63EFD6FD-3196-4F3E-8386-D4074923350E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:linux:linux_kernel:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"703AF700-7A70-47E2-BC3A-7FD03B3CA9C1\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A2572D17-1DE6-457B-99CC-64AFD54487EA\"}]}]}],\"references\":[{\"url\":\"http://www.openwall.com/lists/oss-security/2022/09/06/2\",\"source\":\"psirt@nvidia.com\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://nvidia.custhelp.com/app/answers/detail/a_id/5389\",\"source\":\"psirt@nvidia.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-mlx5-jbPCrqD8\",\"source\":\"psirt@nvidia.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.