cve-2022-31229
Vulnerability from cvelistv5
Published
2022-06-28 18:40
Modified
2024-09-17 04:13
Severity ?
EPSS score ?
Summary
Dell PowerScale OneFS, 8.2.x through 9.3.0.x, contain an error message with sensitive information. An administrator could potentially exploit this vulnerability, leading to disclosure of sensitive information. This sensitive information can be used to access sensitive resources.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Dell | PowerScale OneFS |
Version: unspecified < 8.2.x, 9.0.0.x, 9.1.0.x, 9.1.1.x, 9.2.0.x, 9.2.1.x, 9.3.0.x |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:11:39.900Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000200681/dsa-2022-118-dell-emc-powerscale-onefs-security-update?lang=en" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "PowerScale OneFS", "vendor": "Dell", "versions": [ { "lessThan": "8.2.x, 9.0.0.x, 9.1.0.x, 9.1.1.x, 9.2.0.x, 9.2.1.x, 9.3.0.x", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2022-06-16T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell PowerScale OneFS, 8.2.x through 9.3.0.x, contain an error message with sensitive information. An administrator could potentially exploit this vulnerability, leading to disclosure of sensitive information. This sensitive information can be used to access sensitive resources." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-209", "description": "CWE-209: Information Exposure Through an Error Message", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-06-28T18:40:11", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/kbdoc/en-us/000200681/dsa-2022-118-dell-emc-powerscale-onefs-security-update?lang=en" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2022-06-16", "ID": "CVE-2022-31229", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "PowerScale OneFS", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.2.x, 9.0.0.x, 9.1.0.x, 9.1.1.x, 9.2.0.x, 9.2.1.x, 9.3.0.x" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell PowerScale OneFS, 8.2.x through 9.3.0.x, contain an error message with sensitive information. An administrator could potentially exploit this vulnerability, leading to disclosure of sensitive information. This sensitive information can be used to access sensitive resources." } ] }, "impact": { "cvss": { "baseScore": 9.6, "baseSeverity": "Critical", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-209: Information Exposure Through an Error Message" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/kbdoc/en-us/000200681/dsa-2022-118-dell-emc-powerscale-onefs-security-update?lang=en", "refsource": "MISC", "url": "https://www.dell.com/support/kbdoc/en-us/000200681/dsa-2022-118-dell-emc-powerscale-onefs-security-update?lang=en" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2022-31229", "datePublished": "2022-06-28T18:40:11.660865Z", "dateReserved": "2022-05-19T00:00:00", "dateUpdated": "2024-09-17T04:13:42.167Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-31229\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2022-06-28T19:15:09.487\",\"lastModified\":\"2022-07-09T00:18:04.637\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerScale OneFS, 8.2.x through 9.3.0.x, contain an error message with sensitive information. An administrator could potentially exploit this vulnerability, leading to disclosure of sensitive information. This sensitive information can be used to access sensitive resources.\"},{\"lang\":\"es\",\"value\":\"Dell PowerScale OneFS, versiones 8.2.x hasta 9.3.0.x, contienen un mensaje de error con informaci\u00f3n confidencial. Un administrador podr\u00eda explotar esta vulnerabilidad, conllevando a una divulgaci\u00f3n de informaci\u00f3n confidencial. Esta informaci\u00f3n confidencial puede ser usada para acceder a recursos confidenciales\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":9.6,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.1,\"impactScore\":5.8}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-209\"}]},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-209\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.2.0\",\"versionEndIncluding\":\"9.3.0.0\",\"matchCriteriaId\":\"5DB58188-89E9-4829-B2B0-F53E803AB108\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000200681/dsa-2022-118-dell-emc-powerscale-onefs-security-update?lang=en\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.