cve-2022-31239
Vulnerability from cvelistv5
Published
2022-10-21 18:05
Modified
2024-09-16 22:45
Severity ?
EPSS score ?
Summary
Dell PowerScale OneFS, versions 9.0.0 up to and including 9.1.0.19, 9.2.1.12, and 9.3.0.6, contain sensitive data in log files vulnerability. A privileged local user may potentially exploit this vulnerability, leading to disclosure of this sensitive data.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Dell | PowerScale OneFS |
Version: unspecified < 9.3.0.x |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:11:39.807Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000201094/dsa-2022-149-dell-emc-powerscale-onefs-security-update?lang=en" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "PowerScale OneFS", "vendor": "Dell", "versions": [ { "lessThan": "9.3.0.x", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2022-06-30T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell PowerScale OneFS, versions 9.0.0 up to and including 9.1.0.19, 9.2.1.12, and 9.3.0.6, contain sensitive data in log files vulnerability. A privileged local user may potentially exploit this vulnerability, leading to disclosure of this sensitive data." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-532", "description": "CWE-532: Information Exposure Through Log Files", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-21T00:00:00", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "url": "https://www.dell.com/support/kbdoc/en-us/000201094/dsa-2022-149-dell-emc-powerscale-onefs-security-update?lang=en" } ] } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2022-31239", "datePublished": "2022-10-21T18:05:26.213505Z", "dateReserved": "2022-05-19T00:00:00", "dateUpdated": "2024-09-16T22:45:35.832Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-31239\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2022-10-21T18:15:09.843\",\"lastModified\":\"2022-10-24T15:40:17.393\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerScale OneFS, versions 9.0.0 up to and including 9.1.0.19, 9.2.1.12, and 9.3.0.6, contain sensitive data in log files vulnerability. A privileged local user may potentially exploit this vulnerability, leading to disclosure of this sensitive data.\"},{\"lang\":\"es\",\"value\":\"Dell PowerScale OneFS, versiones 9.0.0 hasta 9.1.0.19, 9.2.1.12 y 9.3.0.6 incluy\u00e9ndola, contienen una vulnerabilidad de datos confidenciales en archivos de registro. Un usuario local privilegiado podr\u00eda explotar esta vulnerabilidad, conllevando a una divulgaci\u00f3n de estos datos confidenciales\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.1.0.0\",\"versionEndIncluding\":\"9.1.0.19\",\"matchCriteriaId\":\"1C0A982E-C690-4103-B27D-F30C7B913D33\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.2.1.0\",\"versionEndIncluding\":\"9.2.1.12\",\"matchCriteriaId\":\"C8C6C3D7-DEF8-4299-B2D9-CADFE9CF6FE6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.3.0.0\",\"versionEndIncluding\":\"9.3.0.6\",\"matchCriteriaId\":\"59849B62-4A3A-4249-9FCF-8C076F94DA22\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000201094/dsa-2022-149-dell-emc-powerscale-onefs-security-update?lang=en\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.