CVE-2022-34465 (GCVE-0-2022-34465)

Vulnerability from cvelistv5 – Published: 2022-07-12 10:07 – Updated: 2024-08-03 09:15
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Affected: All versions < V33.1.264
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:15:15.156Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.264"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.250"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.233"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.250), Parasolid V34.1 (All versions \u003c V34.1.233), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:40:48",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-34465",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.264"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.250"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.233"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.250), Parasolid V34.1 (All versions \u003c V34.1.233), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34465",
    "datePublished": "2022-07-12T10:07:20",
    "dateReserved": "2022-06-24T00:00:00",
    "dateUpdated": "2024-08-03T09:15:15.156Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"33.1\", \"versionEndExcluding\": \"33.1.264\", \"matchCriteriaId\": \"F1405366-A402-4908-858D-E844853BE1DA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\", \"versionStartExcluding\": \"34.0\", \"versionEndExcluding\": \"34.0.250\", \"matchCriteriaId\": \"0ED9DD21-32B1-40AA-AFB6-A9B91B474BED\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\", \"versionStartExcluding\": \"34.1\", \"versionEndExcluding\": \"34.1.233\", \"matchCriteriaId\": \"EBCC315B-2A8F-4E7A-8129-E3C26887B828\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022.1.0\", \"versionEndExcluding\": \"2022.1.3\", \"matchCriteriaId\": \"5CC6B707-5527-4A4F-BA46-C2EE6CCF8E56\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022.2.0\", \"versionEndExcluding\": \"2022.2.2\", \"matchCriteriaId\": \"98BF38F3-E62A-4913-A300-EF7F3001BC64\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.250), Parasolid V34.1 (All versions \u003c V34.1.233), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en Parasolid V33.1 (Todas las versiones anteriores a V33.1.264), Parasolid V34.0 (Todas las versiones anteriores a V34.0.250), Parasolid V34.1 (Todas las versiones anteriores a V34.1.233), Simcenter Femap V2022.1 (Todas las versiones anteriores a V2022.1.3), Simcenter Femap V2022.2 (Todas las versiones anteriores a V2022.2.2). La aplicaci\\u00f3n afectada contiene una lectura fuera de l\\u00edmites m\\u00e1s all\\u00e1 del final de una estructura asignada mientras analiza archivos NEU especialmente dise\\u00f1ados. Esto podr\\u00eda permitir a un atacante ejecutar c\\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15420)\"}]",
      "id": "CVE-2022-34465",
      "lastModified": "2024-11-21T07:09:37.473",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2022-07-12T10:15:12.037",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-34465\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-07-12T10:15:12.037\",\"lastModified\":\"2024-11-21T07:09:37.473\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.250), Parasolid V34.1 (All versions \u003c V34.1.233), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Parasolid V33.1 (Todas las versiones anteriores a V33.1.264), Parasolid V34.0 (Todas las versiones anteriores a V34.0.250), Parasolid V34.1 (Todas las versiones anteriores a V34.1.233), Simcenter Femap V2022.1 (Todas las versiones anteriores a V2022.1.3), Simcenter Femap V2022.2 (Todas las versiones anteriores a V2022.2.2). La aplicaci\u00f3n afectada contiene una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analiza archivos NEU especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15420)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"33.1\",\"versionEndExcluding\":\"33.1.264\",\"matchCriteriaId\":\"F1405366-A402-4908-858D-E844853BE1DA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartExcluding\":\"34.0\",\"versionEndExcluding\":\"34.0.250\",\"matchCriteriaId\":\"0ED9DD21-32B1-40AA-AFB6-A9B91B474BED\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartExcluding\":\"34.1\",\"versionEndExcluding\":\"34.1.233\",\"matchCriteriaId\":\"EBCC315B-2A8F-4E7A-8129-E3C26887B828\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022.1.0\",\"versionEndExcluding\":\"2022.1.3\",\"matchCriteriaId\":\"5CC6B707-5527-4A4F-BA46-C2EE6CCF8E56\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022.2.0\",\"versionEndExcluding\":\"2022.2.2\",\"matchCriteriaId\":\"98BF38F3-E62A-4913-A300-EF7F3001BC64\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…