CVE-2022-3737 (GCVE-0-2022-3737)

Vulnerability from cvelistv5 – Published: 2022-11-15 10:59 – Updated: 2025-04-28 20:18
VLAI?
Summary
In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.
CWE
Assigner
Impacted products
Vendor Product Version
PHOENIX CONTACT Config+ Affected: 0 , ≤ 1.89 (semver)
Create a notification for this product.
Credits
This vulnerability was discovered by Michael Heinzl
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:20:57.710Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-048/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3737",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-28T20:16:23.251507Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-28T20:18:28.564Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Config+",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "1.89",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC Worx",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "1.89",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC Worx Express",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "1.89",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "This vulnerability was discovered by Michael Heinzl"
        }
      ],
      "datePublic": "2022-11-08T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities."
            }
          ],
          "value": "In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-15T10:59:00.713Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2022-048/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to Automation Worx Software Suite \u0026gt; 1.89"
            }
          ],
          "value": "Upgrade to Automation Worx Software Suite \u003e 1.89"
        }
      ],
      "source": {
        "advisory": "VDE-2022-048",
        "defect": [
          "CERT@VDE64164"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Out-of-bounds Read in PHOENIX CONTACT Automationworx Software Suite",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-3737",
    "datePublished": "2022-11-15T10:59:00.713Z",
    "dateReserved": "2022-10-28T07:16:41.383Z",
    "dateUpdated": "2025-04-28T20:18:28.564Z",
    "requesterUserId": "267706bf-c75a-4dca-aafe-11e4a82952d7",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:phoenixcontact:automationworx_software_suite:1.89:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D16C5674-97DC-477C-98D8-A93B47B625BB\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.\"}, {\"lang\": \"es\", \"value\": \"En PHOENIX CONTACT Automationworx Software Suite hasta la versi\\u00f3n 1.89 la memoria puede leerse m\\u00e1s all\\u00e1 de lo previsto debido a una validaci\\u00f3n insuficiente de los datos de entrada. La disponibilidad, la integridad o la confidencialidad de una estaci\\u00f3n de trabajo de programaci\\u00f3n de aplicaciones podr\\u00edan verse comprometidas por ataques que utilicen estas vulnerabilidades.\"}]",
      "id": "CVE-2022-3737",
      "lastModified": "2024-11-21T07:20:08.370",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"info@cert.vde.com\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}]}",
      "published": "2022-11-15T11:15:12.457",
      "references": "[{\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-048/\", \"source\": \"info@cert.vde.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-048/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"info@cert.vde.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-3737\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2022-11-15T11:15:12.457\",\"lastModified\":\"2024-11-21T07:20:08.370\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.\"},{\"lang\":\"es\",\"value\":\"En PHOENIX CONTACT Automationworx Software Suite hasta la versi\u00f3n 1.89 la memoria puede leerse m\u00e1s all\u00e1 de lo previsto debido a una validaci\u00f3n insuficiente de los datos de entrada. La disponibilidad, la integridad o la confidencialidad de una estaci\u00f3n de trabajo de programaci\u00f3n de aplicaciones podr\u00edan verse comprometidas por ataques que utilicen estas vulnerabilidades.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:phoenixcontact:automationworx_software_suite:1.89:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D16C5674-97DC-477C-98D8-A93B47B625BB\"}]}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2022-048/\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert.vde.com/en/advisories/VDE-2022-048/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-048/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T01:20:57.710Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-3737\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-28T20:16:23.251507Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-28T20:18:20.243Z\"}}], \"cna\": {\"title\": \"Out-of-bounds Read in PHOENIX CONTACT Automationworx Software Suite\", \"source\": {\"defect\": [\"CERT@VDE64164\"], \"advisory\": \"VDE-2022-048\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"This vulnerability was discovered by Michael Heinzl\"}], \"impacts\": [{\"capecId\": \"CAPEC-100\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-100 Overflow Buffers\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"PHOENIX CONTACT\", \"product\": \"Config+\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"1.89\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"PHOENIX CONTACT\", \"product\": \"PC Worx\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"1.89\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"PHOENIX CONTACT\", \"product\": \"PC Worx Express\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"1.89\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Upgrade to Automation Worx Software Suite \u003e 1.89\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Upgrade to Automation Worx Software Suite \u0026gt; 1.89\", \"base64\": false}]}], \"datePublic\": \"2022-11-08T08:00:00.000Z\", \"references\": [{\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-048/\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-125\", \"description\": \"CWE-125 Out-of-bounds Read\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2022-11-15T10:59:00.713Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-3737\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-28T20:18:28.564Z\", \"dateReserved\": \"2022-10-28T07:16:41.383Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2022-11-15T10:59:00.713Z\", \"requesterUserId\": \"267706bf-c75a-4dca-aafe-11e4a82952d7\", \"assignerShortName\": \"CERTVDE\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…