cve-2022-3738
Vulnerability from cvelistv5
Published
2023-01-19 11:27
Modified
2024-08-03 01:20
Summary
WAGO: Missing authentication for config export functionality in multiple products
References
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:20:57.784Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-054/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Series WAGO PFC100",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Series WAGO PFC200",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Series WAGO Touch Panel 600 Advanced Line",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Series WAGO Touch Panel 600 Marine Line",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Series WAGO Touch Panel 600 Standard Line",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WAGO Compact Controller CC100",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WAGO Edge Controller",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2023-01-12T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vulnerability allows a remote unauthenticated attacker to download a backup file, if one exists. That backup file might contain sensitive information like credentials and cryptographic material. A valid user has to create a backup after the last reboot for this attack to be successfull.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "The vulnerability allows a remote unauthenticated attacker to download a backup file, if one exists. That backup file might contain sensitive information like credentials and cryptographic material. A valid user has to create a backup after the last reboot for this attack to be successfull.\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-1",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-07T09:43:18.629Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2022-054/"
        }
      ],
      "source": {
        "advisory": "VDE-2022-054",
        "defect": [
          "CERT@VDE#64273"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "WAGO: Missing authentication for config export functionality in multiple products",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-3738",
    "datePublished": "2023-01-19T11:27:51.814Z",
    "dateReserved": "2022-10-28T07:18:40.653Z",
    "dateUpdated": "2024-08-03T01:20:57.784Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-3738\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2023-01-19T12:15:11.213\",\"lastModified\":\"2023-11-07T10:15:07.787\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"The vulnerability allows a remote unauthenticated attacker to download a backup file, if one exists. That backup file might contain sensitive information like credentials and cryptographic material. A valid user has to create a backup after the last reboot for this attack to be successfull.\\n\"},{\"lang\":\"es\",\"value\":\"La vulnerabilidad permite a un atacante remoto no autenticado descargar un archivo de copia de seguridad, si existe. Ese archivo de copia de seguridad puede contener informaci\u00f3n confidencial, como credenciales y material criptogr\u00e1fico. Un usuario v\u00e1lido debe crear una copia de seguridad despu\u00e9s del \u00faltimo reinicio para que este ataque tenga \u00e9xito.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6},{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc100_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"22\",\"matchCriteriaId\":\"15CC83F6-9816-482C-A026-7654BCC95D40\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:pfc100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F636354-95A2-4B36-9666-1FA57F185432\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc200_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"22\",\"matchCriteriaId\":\"6A4AEA6B-206A-4CEA-ACCE-145B139DF58B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"688A3248-7EAA-499D-A47C-A4D4900CDBD1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_advanced_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"22\",\"matchCriteriaId\":\"35EF27EB-EE11-47B6-8382-47910AA3966B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:touch_panel_600_advanced:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A8221861-7455-41D5-B310-6AEA822B46CF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_standard_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"22\",\"matchCriteriaId\":\"A470D085-96C4-4DFE-A4E2-1407D49A4D9A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:touch_panel_600_standard:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6D7A44C-2D95-4F69-A7DB-435B0A6F9F03\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_marine_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"22\",\"matchCriteriaId\":\"79C7DB93-4282-49DB-B81E-44BBD826BFF8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:touch_panel_600_marine:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83DEFFBC-934D-43BE-92AE-25F8EE8C1E0A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:cc100_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"22\",\"matchCriteriaId\":\"8A3E10E2-A0AA-47E2-B314-51A86BEB2208\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:cc100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"632388B3-E59E-480E-9F0F-08A9F4E87159\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:edge_controller_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"22\",\"matchCriteriaId\":\"F31F6E66-78B4-4F7B-BAE6-0C38D1307A4B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:edge_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2DFC57C8-6AF4-4771-B0A0-744137FBFECF\"}]}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2022-054/\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.