cve-2022-41661
Vulnerability from cvelistv5
Published
2022-11-08 00:00
Modified
2024-08-03 12:49
Summary
A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:49:43.627Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V14.1.0.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.0.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.0.0.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter Visualization V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1.0.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c  V14.1.0.4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-13T08:16:51.110Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-41661",
    "datePublished": "2022-11-08T00:00:00",
    "dateReserved": "2022-09-27T00:00:00",
    "dateUpdated": "2024-08-03T12:49:43.627Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-41661\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-11-08T11:15:11.623\",\"lastModified\":\"2023-06-13T09:15:15.097\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions \u003c  V14.1.0.4), Teamcenter Visualization V13.2 (All versions \u003c V13.2.0.12), Teamcenter Visualization V13.3 (All versions \u003c V13.3.0.7), Teamcenter Visualization V14.0 (All versions \u003c V14.0.0.3), Teamcenter Visualization V14.1 (All versions \u003c V14.1.0.4). The affected products contain an out of bounds read vulnerability when parsing a CGM file. An attacker can leverage this vulnerability to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones \u0026lt; V14.1.0.4), Teamcenter Visualization V13.2 (Todas las versiones \u0026lt; V13.2.0.12), Teamcenter Visualization V13.3 (Todas las versiones \u0026lt; V13.3.0. 7), Teamcenter Visualization V14.0 (todas las versiones \u0026lt; V14.0.0.3), Teamcenter Visualization V14.1 (todas las versiones \u0026lt; V14.1.0.4). Los productos afectados contienen una vulnerabilidad de lectura fuera de l\u00edmites al analizar un archivo CGM. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"14.1.0.4\",\"matchCriteriaId\":\"FD5EAF75-B0F4-4792-9833-085B9D830FCE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.3.0\",\"versionEndExcluding\":\"13.3.0.7\",\"matchCriteriaId\":\"FB99D790-4F55-48F2-902B-8739CAEC78EE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.0\",\"versionEndExcluding\":\"14.0.0.3\",\"matchCriteriaId\":\"0F811DB6-3650-4BCB-A538-AAECF63EA085\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.1\",\"versionEndExcluding\":\"14.1.0.4\",\"matchCriteriaId\":\"175648D0-81ED-4AC9-AF2D-4C9E93814C36\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...