cve-2023-2266
Vulnerability from cvelistv5
Published
2023-11-30 16:57
Modified
2024-08-02 06:19
Summary
Improper neutralization of input during web page generation could lead to cross-site scripting based attacks
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:19:14.119Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-411L",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R118-V4",
              "status": "affected",
              "version": "R118-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R119-V5",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R120-V6",
              "status": "affected",
              "version": "R120-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R121-V3",
              "status": "affected",
              "version": "R121-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R122-V3",
              "status": "affected",
              "version": "R122-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R123-V3",
              "status": "affected",
              "version": "R123-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R124-V3",
              "status": "affected",
              "version": "R124-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R125-V3",
              "status": "affected",
              "version": "R125-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R126-V4",
              "status": "affected",
              "version": "R126-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R127-V2",
              "status": "affected",
              "version": "R127-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R128-V1",
              "status": "affected",
              "version": "R128-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R129-V1",
              "status": "affected",
              "version": "R129-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Sushant Mane, Parul Sindhwad, Imran Jamadar \u0026 Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai, India."
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An\u0026nbsp;Improper neutralization of input during web page generation in the Schweitzer Engineering Laboratories SEL-411L\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ecould allow an attacker to generate cross-site scripting based attacks against an authorized and authenticated user.\u003cbr\u003e\u003cbr\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "An\u00a0Improper neutralization of input during web page generation in the Schweitzer Engineering Laboratories SEL-411L\u00a0could allow an attacker to generate cross-site scripting based attacks against an authorized and authenticated user.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-63",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-63 Cross-Site Scripting (XSS)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:58:00.174Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper neutralization of input during web page generation could lead to cross-site scripting based attacks",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-2266",
    "datePublished": "2023-11-30T16:57:34.955Z",
    "dateReserved": "2023-04-24T23:21:09.897Z",
    "dateUpdated": "2024-08-02T06:19:14.119Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-2266\",\"sourceIdentifier\":\"security@selinc.com\",\"published\":\"2023-11-30T17:15:08.170\",\"lastModified\":\"2023-12-06T00:35:24.197\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"An\u00a0Improper neutralization of input during web page generation in the Schweitzer Engineering Laboratories SEL-411L\u00a0could allow an attacker to generate cross-site scripting based attacks against an authorized and authenticated user.\\n\\n\\n\\nSee product Instruction Manual Appendix A dated 20230830 for more details.\\n\\n\\n\"},{\"lang\":\"es\",\"value\":\"Una neutralizaci\u00f3n inadecuada de la entrada durante la generaci\u00f3n de una p\u00e1gina web en Schweitzer Engineering Laboratories SEL-411L podr\u00eda permitir a un atacante generar ataques basados en cross site scripting contra un usuario autorizado y autenticado. Consulte el Ap\u00e9ndice A del Manual de instrucciones del producto con fecha 20230830 para obtener m\u00e1s detalles.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"security@selinc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"security@selinc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:selinc:sel-411l:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"775B0B13-EF38-4AAE-892D-975374673480\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r118-v0\",\"versionEndExcluding\":\"r118-v4\",\"matchCriteriaId\":\"49894C1C-F351-48C1-9B0C-ADEF9F15967F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r119-v0\",\"versionEndExcluding\":\"r119-v5\",\"matchCriteriaId\":\"D50FA357-FD76-4D6E-BE33-F023EF8EA6D4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r120-v0\",\"versionEndExcluding\":\"r120-v6\",\"matchCriteriaId\":\"F2C5D52B-BE58-41ED-9660-88FCD87EBBBF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r121-v0\",\"versionEndExcluding\":\"r121-v3\",\"matchCriteriaId\":\"97CF37D0-9DF4-4277-A948-57D0677361DE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r122-v0\",\"versionEndExcluding\":\"r122-v3\",\"matchCriteriaId\":\"5E81C049-DCDA-46D7-A3FD-337663171A4B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r123-v0\",\"versionEndExcluding\":\"r123-v3\",\"matchCriteriaId\":\"6B30BA03-4595-4537-B88A-7DB8D4E565F0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r124-v0\",\"versionEndExcluding\":\"r124-v3\",\"matchCriteriaId\":\"4A5DE8B0-BB5F-49E5-8039-6A7466E3265C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r125-v0\",\"versionEndExcluding\":\"r125-v3\",\"matchCriteriaId\":\"622B4133-6FDE-49D6-A768-ADFB0AB829A6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r126-v0\",\"versionEndExcluding\":\"r126-v4\",\"matchCriteriaId\":\"B913BE75-D4F1-40C9-9450-C195C84E7EAE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"r127-v0\",\"versionEndExcluding\":\"r127-v2\",\"matchCriteriaId\":\"90C6D8F0-54F0-46CD-994C-524E9593EEE3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:r128-v0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80116398-08C8-4571-B90D-E96530E0A17D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:selinc:sel-411l_firmware:r129-v0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"59DB9510-A827-4E5C-B41F-CCB38837BCFB\"}]}]}],\"references\":[{\"url\":\"https://selinc.com/support/security-notifications/external-reports/\",\"source\":\"security@selinc.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.