CVE-2023-23588 (GCVE-0-2023-23588)

Vulnerability from cvelistv5 – Published: 2023-04-11 09:03 – Updated: 2024-10-15 17:12
VLAI?
Summary
A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application. A local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit.
CWE
  • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC IPC1047 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC IPC1047E Affected: All versions with maxView Storage Manager < 4.09.00.25611 on Windows
Create a notification for this product.
    Siemens SIMATIC IPC647D Affected: All versions
Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: All versions with maxView Storage Manager < 4.09.00.25611 on Windows
Create a notification for this product.
    Siemens SIMATIC IPC847D Affected: All versions
Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: All versions with maxView Storage Manager < 4.09.00.25611 on Windows
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:35:33.386Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-23588",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T17:09:07.958283Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T17:12:13.841Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC1047",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC1047E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC647D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC647E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC847D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC847E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application.\r\nA local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:03:01.130Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-23588",
    "datePublished": "2023-04-11T09:03:01.130Z",
    "dateReserved": "2023-01-13T14:55:01.563Z",
    "dateUpdated": "2024-10-15T17:12:13.841Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_ipc647d_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"43337EC1-0BF8-40B3-88BC-38F06EF48DC6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_ipc647d:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D0EF28FB-BAB3-4710-9D25-25F67ACADC60\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_ipc847d_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"681C8A24-C3AC-4CF4-8283-DAC337909CC9\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_ipc847d:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D8F37D88-E086-4060-8420-BD0F8D8FF580\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_ipc1047_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E5DA20C3-90EE-4355-99FC-BACE6F77C56C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_ipc1047:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5E959C97-838B-41F6-BD73-AA5073975075\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:microchip:maxview_storage_manager:*:*:*:*:*:windows:*:*\", \"versionEndExcluding\": \"4.09.00.25611\", \"matchCriteriaId\": \"77C02716-54AE-4545-AB8C-4760F92271A2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_ipc1047e:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"85F2895E-AFB0-4516-B549-93CCD5BB5814\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E430C4C5-D887-47C6-B50F-66EEE9519151\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1157418C-14C4-43C4-B63E-7E98D868A94F\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application.\\r\\nA local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit.\"}]",
      "id": "CVE-2023-23588",
      "lastModified": "2024-11-21T07:46:29.217",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 6.2, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.5, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.0, \"impactScore\": 5.2}]}",
      "published": "2023-04-11T10:15:18.097",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-200\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-295\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-23588\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-04-11T10:15:18.097\",\"lastModified\":\"2024-11-21T07:46:29.217\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application.\\r\\nA local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.2,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.5,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.0,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-295\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc647d_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"43337EC1-0BF8-40B3-88BC-38F06EF48DC6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc647d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D0EF28FB-BAB3-4710-9D25-25F67ACADC60\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc847d_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"681C8A24-C3AC-4CF4-8283-DAC337909CC9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc847d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D8F37D88-E086-4060-8420-BD0F8D8FF580\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc1047_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5DA20C3-90EE-4355-99FC-BACE6F77C56C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc1047:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5E959C97-838B-41F6-BD73-AA5073975075\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microchip:maxview_storage_manager:*:*:*:*:*:windows:*:*\",\"versionEndExcluding\":\"4.09.00.25611\",\"matchCriteriaId\":\"77C02716-54AE-4545-AB8C-4760F92271A2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc1047e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85F2895E-AFB0-4516-B549-93CCD5BB5814\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E430C4C5-D887-47C6-B50F-66EEE9519151\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1157418C-14C4-43C4-B63E-7E98D868A94F\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T10:35:33.386Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-23588\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-15T17:09:07.958283Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-15T17:10:42.721Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.2, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC1047\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC1047E\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC647D\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC647E\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC847D\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC IPC847E\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application.\\r\\nA local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-200\", \"description\": \"CWE-200: Exposure of Sensitive Information to an Unauthorized Actor\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2023-04-11T09:03:01.130Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-23588\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-15T17:12:13.841Z\", \"dateReserved\": \"2023-01-13T14:55:01.563Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2023-04-11T09:03:01.130Z\", \"assignerShortName\": \"siemens\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…