CVE-2023-2395 (GCVE-0-2023-2395)

Vulnerability from cvelistv5 – Published: 2023-04-28 21:31 – Updated: 2025-02-12 16:42
VLAI?
Title
Netgear SRX5308 Web Management Interface cross site scripting
Summary
A vulnerability classified as problematic has been found in Netgear SRX5308 up to 4.3.5-3. This affects an unknown part of the component Web Management Interface. The manipulation of the argument Login.userAgent leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227673 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-79 - Cross Site Scripting
Assigner
References
https://vuldb.com/?id.227673 vdb-entrytechnical-description
https://vuldb.com/?ctiid.227673 signaturepermissions-required
https://github.com/leetsun/IoT/tree/main/Netgear-… broken-linkexploit
Impacted products
Vendor Product Version
Netgear SRX5308 Affected: 4.3.5-3
Create a notification for this product.
Credits
leetsun (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:19:15.140Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.227673"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.227673"
          },
          {
            "tags": [
              "broken-link",
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/leetsun/IoT/tree/main/Netgear-SRX5308/15"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-2395",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-30T16:58:30.683092Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T16:42:25.895Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Web Management Interface"
          ],
          "product": "SRX5308",
          "vendor": "Netgear",
          "versions": [
            {
              "status": "affected",
              "version": "4.3.5-3"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "leetsun (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as problematic has been found in Netgear SRX5308 up to 4.3.5-3. This affects an unknown part of the component Web Management Interface. The manipulation of the argument Login.userAgent leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227673 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Netgear SRX5308 bis 4.3.5-3 entdeckt. Sie wurde als problematisch eingestuft. Dabei betrifft es einen unbekannter Codeteil der Komponente Web Management Interface. Mittels Manipulieren des Arguments Login.userAgent mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross Site Scripting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-13T07:21:30.643Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.227673"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.227673"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://github.com/leetsun/IoT/tree/main/Netgear-SRX5308/15"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-04-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-04-28T00:00:00.000Z",
          "value": "CVE reserved"
        },
        {
          "lang": "en",
          "time": "2023-04-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-05-21T20:04:53.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Netgear SRX5308 Web Management Interface cross site scripting"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-2395",
    "datePublished": "2023-04-28T21:31:03.804Z",
    "dateReserved": "2023-04-28T11:49:07.265Z",
    "dateUpdated": "2025-02-12T16:42:25.895Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:srx5308_firmware:4.3.5-3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"33645096-A648-4674-8045-6EF6538D7E28\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:srx5308:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5768789E-33BD-4F4C-A8B4-5F8D2FAE6F62\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability classified as problematic has been found in Netgear SRX5308 up to 4.3.5-3. This affects an unknown part of the component Web Management Interface. The manipulation of the argument Login.userAgent leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227673 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}]",
      "id": "CVE-2023-2395",
      "lastModified": "2024-11-21T07:58:31.950",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N\", \"baseScore\": 4.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 1.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:P/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2023-04-28T22:15:09.130",
      "references": "[{\"url\": \"https://github.com/leetsun/IoT/tree/main/Netgear-SRX5308/15\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?ctiid.227673\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Permissions Required\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://vuldb.com/?id.227673\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Permissions Required\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://github.com/leetsun/IoT/tree/main/Netgear-SRX5308/15\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?ctiid.227673\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Permissions Required\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://vuldb.com/?id.227673\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Permissions Required\", \"Third Party Advisory\", \"VDB Entry\"]}]",
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"cna@vuldb.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-2395\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2023-04-28T22:15:09.130\",\"lastModified\":\"2024-11-21T07:58:31.950\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability classified as problematic has been found in Netgear SRX5308 up to 4.3.5-3. This affects an unknown part of the component Web Management Interface. The manipulation of the argument Login.userAgent leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227673 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:P/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:srx5308_firmware:4.3.5-3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33645096-A648-4674-8045-6EF6538D7E28\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:srx5308:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5768789E-33BD-4F4C-A8B4-5F8D2FAE6F62\"}]}]}],\"references\":[{\"url\":\"https://github.com/leetsun/IoT/tree/main/Netgear-SRX5308/15\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.227673\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.227673\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://github.com/leetsun/IoT/tree/main/Netgear-SRX5308/15\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.227673\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.227673\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://vuldb.com/?id.227673\", \"tags\": [\"vdb-entry\", \"technical-description\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?ctiid.227673\", \"tags\": [\"signature\", \"permissions-required\", \"x_transferred\"]}, {\"url\": \"https://github.com/leetsun/IoT/tree/main/Netgear-SRX5308/15\", \"tags\": [\"broken-link\", \"exploit\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T06:19:15.140Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-2395\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-30T16:58:30.683092Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-12T16:42:20.266Z\"}}], \"cna\": {\"title\": \"Netgear SRX5308 Web Management Interface cross site scripting\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"leetsun (VulDB User)\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 4.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 4.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 5, \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:P/A:N\"}}], \"affected\": [{\"vendor\": \"Netgear\", \"modules\": [\"Web Management Interface\"], \"product\": \"SRX5308\", \"versions\": [{\"status\": \"affected\", \"version\": \"4.3.5-3\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2023-04-28T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2023-04-28T00:00:00.000Z\", \"value\": \"CVE reserved\"}, {\"lang\": \"en\", \"time\": \"2023-04-28T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2023-05-21T20:04:53.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.227673\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.227673\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://github.com/leetsun/IoT/tree/main/Netgear-SRX5308/15\", \"tags\": [\"broken-link\", \"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability classified as problematic has been found in Netgear SRX5308 up to 4.3.5-3. This affects an unknown part of the component Web Management Interface. The manipulation of the argument Login.userAgent leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227673 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"Es wurde eine Schwachstelle in Netgear SRX5308 bis 4.3.5-3 entdeckt. Sie wurde als problematisch eingestuft. Dabei betrifft es einen unbekannter Codeteil der Komponente Web Management Interface. Mittels Manipulieren des Arguments Login.userAgent mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \\u00fcber das Netzwerk erfolgen. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Cross Site Scripting\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2024-02-13T07:21:30.643Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-2395\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-12T16:42:25.895Z\", \"dateReserved\": \"2023-04-28T11:49:07.265Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2023-04-28T21:31:03.804Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…