CVE-2023-24837 (GCVE-0-2023-24837)

Vulnerability from cvelistv5 – Published: 2023-03-27 00:00 – Updated: 2025-02-19 16:27
VLAI?
Summary
HGiga PowerStation remote management function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can exploit this vulnerability to inject and execute arbitrary system commands to perform arbitrary system operation or disrupt service.
CWE
  • CWE-78 - OS Command Injection
Assigner
Impacted products
Vendor Product Version
HGiga PowerStation Affected: unspecified , < x64.6.2.165 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T11:03:19.288Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.twcert.org.tw/tw/cp-132-6956-fbd85-1.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-24837",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-19T16:27:33.835814Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-19T16:27:37.410Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PowerStation",
          "vendor": "HGiga",
          "versions": [
            {
              "lessThan": "x64.6.2.165",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2023-02-24T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "HGiga PowerStation remote management function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can exploit this vulnerability to inject and execute arbitrary system commands to perform arbitrary system operation or disrupt service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-27T00:00:00.000Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "url": "https://www.twcert.org.tw/tw/cp-132-6956-fbd85-1.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update PowerStation firmware version to x64.6.2.165, then reboot PowerStation."
        }
      ],
      "source": {
        "advisory": "TVN-202302005",
        "discovery": "EXTERNAL"
      },
      "title": "HGiga PowerStation - Command Injection",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2023-24837",
    "datePublished": "2023-03-27T00:00:00.000Z",
    "dateReserved": "2023-01-31T00:00:00.000Z",
    "dateUpdated": "2025-02-19T16:27:37.410Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hgiga:powerstation_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"x64.6.2.165\", \"matchCriteriaId\": \"C3553132-CE95-4A61-9188-22D479C3E8A5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hgiga:powerstation:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4335A03A-1D0E-4DC9-A71B-FA627DB38B2F\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"HGiga PowerStation remote management function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can exploit this vulnerability to inject and execute arbitrary system commands to perform arbitrary system operation or disrupt service.\"}]",
      "id": "CVE-2023-24837",
      "lastModified": "2024-11-21T07:48:29.740",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"twcert@cert.org.tw\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}]}",
      "published": "2023-03-27T04:15:09.830",
      "references": "[{\"url\": \"https://www.twcert.org.tw/tw/cp-132-6956-fbd85-1.html\", \"source\": \"twcert@cert.org.tw\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.twcert.org.tw/tw/cp-132-6956-fbd85-1.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
      "sourceIdentifier": "twcert@cert.org.tw",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"twcert@cert.org.tw\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-24837\",\"sourceIdentifier\":\"twcert@cert.org.tw\",\"published\":\"2023-03-27T04:15:09.830\",\"lastModified\":\"2024-11-21T07:48:29.740\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"HGiga PowerStation remote management function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can exploit this vulnerability to inject and execute arbitrary system commands to perform arbitrary system operation or disrupt service.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"twcert@cert.org.tw\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"twcert@cert.org.tw\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hgiga:powerstation_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"x64.6.2.165\",\"matchCriteriaId\":\"C3553132-CE95-4A61-9188-22D479C3E8A5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hgiga:powerstation:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4335A03A-1D0E-4DC9-A71B-FA627DB38B2F\"}]}]}],\"references\":[{\"url\":\"https://www.twcert.org.tw/tw/cp-132-6956-fbd85-1.html\",\"source\":\"twcert@cert.org.tw\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.twcert.org.tw/tw/cp-132-6956-fbd85-1.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.twcert.org.tw/tw/cp-132-6956-fbd85-1.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T11:03:19.288Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-24837\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-19T16:27:33.835814Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-19T16:27:31.200Z\"}}], \"cna\": {\"title\": \"HGiga PowerStation - Command Injection\", \"source\": {\"advisory\": \"TVN-202302005\", \"discovery\": \"EXTERNAL\"}, \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"HGiga\", \"product\": \"PowerStation\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"lessThan\": \"x64.6.2.165\", \"versionType\": \"custom\"}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Update PowerStation firmware version to x64.6.2.165, then reboot PowerStation.\"}], \"datePublic\": \"2023-02-24T00:00:00.000Z\", \"references\": [{\"url\": \"https://www.twcert.org.tw/tw/cp-132-6956-fbd85-1.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"HGiga PowerStation remote management function has insufficient filtering for user input. An authenticated remote attacker with general user privilege can exploit this vulnerability to inject and execute arbitrary system commands to perform arbitrary system operation or disrupt service.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 OS Command Injection\"}]}], \"providerMetadata\": {\"orgId\": \"cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e\", \"shortName\": \"twcert\", \"dateUpdated\": \"2023-03-27T00:00:00.000Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-24837\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-19T16:27:37.410Z\", \"dateReserved\": \"2023-01-31T00:00:00.000Z\", \"assignerOrgId\": \"cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e\", \"datePublished\": \"2023-03-27T00:00:00.000Z\", \"assignerShortName\": \"twcert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…