cve-2023-29128
Vulnerability from cvelistv5
Published
2023-05-09 11:51
Modified
2024-08-02 14:00
Summary
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:15.230Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC712",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Cloud Connect 7 CC716",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.0 \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:35.346Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-29128",
    "datePublished": "2023-05-09T11:51:35.346Z",
    "dateReserved": "2023-03-31T10:54:25.289Z",
    "dateUpdated": "2024-08-02T14:00:15.230Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-29128\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-05-09T13:15:17.843\",\"lastModified\":\"2023-05-15T18:21:42.613\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":2.7,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":1.2,\"impactScore\":1.4},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\",\"baseScore\":3.8,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":1.2,\"impactScore\":2.5}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk1411-1ac00_firmware:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1F685FA-A737-4D3D-AF47-837D30EBD898\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A62A87CC-250C-469E-9D2C-187271020EE6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk1411-5ac00_firmware:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CAD8CE67-41F5-4673-BC79-EF290971FF20\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7804B194-FECA-4D73-9D49-4B7E8FD49258\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.