cve-2023-32457
Vulnerability from cvelistv5
Published
2023-08-29 07:59
Modified
2024-10-02 13:44
Severity ?
EPSS score ?
Summary
Dell PowerScale OneFS, versions 8.2.2.x-9.5.0.x, contains an improper privilege management vulnerability. A remote attacker with low privileges could potentially exploit this vulnerability, leading to escalation of privileges.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Dell | PowerScale OneFS |
Version: Version 9.2.1.0 through 9.2.1.22 Version: Version 9.4.0.0 through 9.4.0.13 Version: Version 9.5.0.0 through 9.5.0.3 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:18:37.240Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000216916/dsa-2023-277-security-update-for-dell-powerscale-onefs-for-improper-privilege-management-vulnerability" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "powerscale_onefs", "vendor": "dell", "versions": [ { "lessThanOrEqual": "9.2.1.22", "status": "affected", "version": "9.2.1.0", "versionType": "custom" }, { "lessThanOrEqual": "9.4.0.13", "status": "affected", "version": "9.4.0.0", "versionType": "custom" }, { "lessThanOrEqual": "9.5.0.3", "status": "affected", "version": "9.5.0.0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-32457", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-02T13:41:08.333547Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-02T13:44:43.699Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerScale OneFS", "vendor": "Dell", "versions": [ { "status": "affected", "version": "Version 9.2.1.0 through 9.2.1.22" }, { "status": "affected", "version": "Version 9.4.0.0 through 9.4.0.13" }, { "status": "affected", "version": "Version 9.5.0.0 through 9.5.0.3" } ] } ], "datePublic": "2023-08-29T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerScale OneFS, versions 8.2.2.x-9.5.0.x, contains an improper privilege management vulnerability. A remote attacker with low privileges could potentially exploit this vulnerability, leading to escalation of privileges.\u003c/span\u003e\n\n" } ], "value": "\nDell PowerScale OneFS, versions 8.2.2.x-9.5.0.x, contains an improper privilege management vulnerability. A remote attacker with low privileges could potentially exploit this vulnerability, leading to escalation of privileges.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-267", "description": "CWE-267: Privilege Defined With Unsafe Actions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-29T07:59:08.890Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000216916/dsa-2023-277-security-update-for-dell-powerscale-onefs-for-improper-privilege-management-vulnerability" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2023-32457", "datePublished": "2023-08-29T07:59:08.890Z", "dateReserved": "2023-05-09T06:05:24.993Z", "dateUpdated": "2024-10-02T13:44:43.699Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-32457\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2023-08-29T08:15:34.120\",\"lastModified\":\"2023-09-01T14:00:35.670\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nDell PowerScale OneFS, versions 8.2.2.x-9.5.0.x, contains an improper privilege management vulnerability. A remote attacker with low privileges could potentially exploit this vulnerability, leading to escalation of privileges.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Dell PowerScale OneFS, versiones 8.2.2.x-9.5.0.x, contiene una vulnerabilidad de administraci\u00f3n de privilegios incorrecta. Un atacante remoto con pocos privilegios podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda una escalada de privilegios.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-267\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.2.1.0\",\"versionEndIncluding\":\"9.2.1.22\",\"matchCriteriaId\":\"FEF3F09E-3FF7-4352-A853-41DC25627EAD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.4.0.0\",\"versionEndIncluding\":\"9.4.0.13\",\"matchCriteriaId\":\"F49A7E9F-F753-48EA-8A96-CFE473CBD81A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.5.0.0\",\"versionEndIncluding\":\"9.5.0.3\",\"matchCriteriaId\":\"AB96F54D-D8C1-439A-BA83-72B8E840DFB1\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000216916/dsa-2023-277-security-update-for-dell-powerscale-onefs-for-improper-privilege-management-vulnerability\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.