CVE-2023-3329 (GCVE-0-2023-3329)

Vulnerability from cvelistv5 – Published: 2023-08-02 22:26 – Updated: 2024-10-29 17:48
VLAI?
Summary
SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI's upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting system files and creating a denial-of-service condition.
Severity ?
No CVSS data available.
Assigner
Impacted products
Vendor Product Version
iniNet SCADAWebServer Affected: 0 , ≤ 2.08 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:55:03.291Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-173-03"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-3329",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-29T17:48:36.940300Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-22",
                "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-29T17:48:43.098Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCADAWebServer",
          "vendor": "iniNet",
          "versions": [
            {
              "lessThanOrEqual": "2.08",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI\u0027s upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting system files and creating a denial-of-service condition."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-02T22:26:07.157Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-173-03"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-3329",
      "x_generator": {
        "engine": "VINCE 2.1.3",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-3329"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-3329",
    "datePublished": "2023-08-02T22:26:07.157Z",
    "dateReserved": "2023-06-19T17:52:02.498Z",
    "dateUpdated": "2024-10-29T17:48:43.098Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:spidercontrol:scadawebserver:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2.08\", \"matchCriteriaId\": \"7EDC0851-BDA7-4653-8696-BBF08E93D6CB\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI\u0027s upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting system files and creating a denial-of-service condition.\"}]",
      "id": "CVE-2023-3329",
      "lastModified": "2024-11-21T08:17:01.620",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.2}]}",
      "published": "2023-08-02T23:15:10.547",
      "references": "[{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-173-03\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-173-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-22\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-3329\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2023-08-02T23:15:10.547\",\"lastModified\":\"2024-11-21T08:17:01.620\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI\u0027s upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting system files and creating a denial-of-service condition.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:spidercontrol:scadawebserver:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.08\",\"matchCriteriaId\":\"7EDC0851-BDA7-4653-8696-BBF08E93D6CB\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-173-03\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-173-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-173-03\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T06:55:03.291Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-3329\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-29T17:48:36.940300Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-22\", \"description\": \"CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-17T18:42:29.868Z\"}}], \"cna\": {\"title\": \"CVE-2023-3329\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"affected\": [{\"vendor\": \"iniNet\", \"product\": \"SCADAWebServer\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"2.08\"}]}], \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-173-03\"}], \"x_generator\": {\"env\": \"prod\", \"engine\": \"VINCE 2.1.3\", \"origin\": \"https://cveawg.mitre.org/api/cve/CVE-2023-3329\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI\u0027s upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting system files and creating a denial-of-service condition.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2023-08-02T22:26:07.157Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-3329\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-29T17:48:43.098Z\", \"dateReserved\": \"2023-06-19T17:52:02.498Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2023-08-02T22:26:07.157Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…