cve-2023-36635
Vulnerability from cvelistv5
Published
2023-09-07 12:41
Modified
2024-08-02 16:52
Severity
Summary
An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2
7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API.
References
Source | URL | Tags |
---|---|---|
psirt@fortinet.com | https://fortiguard.com/psirt/FG-IR-22-174 | Not Applicable, Vendor Advisory |
Impacted products
Vendor | Product |
---|---|
Fortinet | FortiSwitchManager |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:52:54.065Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://fortiguard.com/psirt/FG-IR-22-174", "tags": [ "x_transferred" ], "url": "https://fortiguard.com/psirt/FG-IR-22-174" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FortiSwitchManager", "vendor": "Fortinet", "versions": [ { "lessThanOrEqual": "7.2.2", "status": "affected", "version": "7.2.0", "versionType": "semver" }, { "lessThanOrEqual": "7.0.1", "status": "affected", "version": "7.0.0", "versionType": "semver" } ] } ], "descriptions": [ { "lang": "en", "value": "An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2\r\n7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H/E:F/RL:X/RC:X", "version": "3.1" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "Improper access control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-09-07T12:41:13.903Z", "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8", "shortName": "fortinet" }, "references": [ { "name": "https://fortiguard.com/psirt/FG-IR-22-174", "url": "https://fortiguard.com/psirt/FG-IR-22-174" } ], "solutions": [ { "lang": "en", "value": "Please upgrade to FortiOS version 7.2.1 or above\r\nPlease upgrade to FortiOS version 7.0.8 or above\r\nPlease upgrade to FortiSwitchManager version 7.2.2 or above\r\nPlease upgrade to FortiSwitchManager version 7.0.2 or above" } ] } }, "cveMetadata": { "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8", "assignerShortName": "fortinet", "cveId": "CVE-2023-36635", "datePublished": "2023-09-07T12:41:13.903Z", "dateReserved": "2023-06-25T18:03:39.226Z", "dateUpdated": "2024-08-02T16:52:54.065Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-36635\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2023-09-07T13:15:08.433\",\"lastModified\":\"2023-11-07T04:16:39.410\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2\\r\\n7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API.\"},{\"lang\":\"es\",\"value\":\"Un control de acceso incorrecto en Fortinet FortiSwitchManager, versiones 7.2.0 a 7.2.2 y versiones 7.0.0 a 7.0.1, puede permitir que un usuario remoto autenticado con permisos de solo lectura modifique la configuraci\u00f3n de la interfaz a trav\u00e9s de la API.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4},{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":4.2}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]},{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiswitchmanager:7.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5B4A6B0D-1614-443B-8EBA-A8FBC2E1A832\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiswitchmanager:7.0.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"331A1766-4EBA-4519-A8ED-E0DD68A187E9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiswitchmanager:7.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2B73D78B-2270-45B7-854E-F985B8D88F3B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiswitchmanager:7.2.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"469E9E1C-154C-41CB-AC83-FBE5E6FA83EB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiswitchmanager:7.2.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"959248C7-DC92-4968-87F9-2A2CDF84F7BE\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.com/psirt/FG-IR-22-174\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Not Applicable\",\"Vendor Advisory\"]}]}}" } }
Loading...