cve-2023-44352
Vulnerability from cvelistv5
Published
2023-11-17 13:31
Modified
2024-10-29 16:06
Summary
Unauthenticate Reflected XSS on Adobe Coldfusion 2018 - 2021 - 2023 last version
Impacted products
AdobeColdFusion
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:07:33.117Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://helpx.adobe.com/security/products/coldfusion/apsb23-52.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-44352",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-16T18:55:37.546184Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-29T16:06:40.067Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "ColdFusion",
          "vendor": "Adobe",
          "versions": [
            {
              "lessThanOrEqual": "2021.11",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2023-11-14T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Adobe ColdFusion versions 2023.5 (and earlier) and 2021.11 (and earlier) are affected by a reflected Cross-Site Scripting (XSS) vulnerability. If an unauthenticated attacker is able to convince a victim to visit a URL referencing a vulnerable page, malicious JavaScript content may be executed within the context of the victim\u0027s browser."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "confidentialityRequirement": "NOT_DEFINED",
            "environmentalScore": 6.1,
            "environmentalSeverity": "MEDIUM",
            "exploitCodeMaturity": "NOT_DEFINED",
            "integrityImpact": "LOW",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "LOW",
            "modifiedAttackVector": "NETWORK",
            "modifiedAvailabilityImpact": "NONE",
            "modifiedConfidentialityImpact": "LOW",
            "modifiedIntegrityImpact": "LOW",
            "modifiedPrivilegesRequired": "NONE",
            "modifiedScope": "NOT_DEFINED",
            "modifiedUserInteraction": "REQUIRED",
            "privilegesRequired": "NONE",
            "remediationLevel": "NOT_DEFINED",
            "reportConfidence": "NOT_DEFINED",
            "scope": "CHANGED",
            "temporalScore": 6.1,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "Cross-site Scripting (Reflected XSS) (CWE-79)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-17T13:31:31.903Z",
        "orgId": "078d4453-3bcd-4900-85e6-15281da43538",
        "shortName": "adobe"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://helpx.adobe.com/security/products/coldfusion/apsb23-52.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Unauthenticate Reflected XSS on Adobe Coldfusion 2018 - 2021 - 2023 last version"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "078d4453-3bcd-4900-85e6-15281da43538",
    "assignerShortName": "adobe",
    "cveId": "CVE-2023-44352",
    "datePublished": "2023-11-17T13:31:31.903Z",
    "dateReserved": "2023-09-28T16:25:40.451Z",
    "dateUpdated": "2024-10-29T16:06:40.067Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-44352\",\"sourceIdentifier\":\"psirt@adobe.com\",\"published\":\"2023-11-17T14:15:21.693\",\"lastModified\":\"2023-11-23T03:36:27.907\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Adobe ColdFusion versions 2023.5 (and earlier) and 2021.11 (and earlier) are affected by a reflected Cross-Site Scripting (XSS) vulnerability. If an unauthenticated attacker is able to convince a victim to visit a URL referencing a vulnerable page, malicious JavaScript content may be executed within the context of the victim\u0027s browser.\"},{\"lang\":\"es\",\"value\":\"Las versiones 2023.5 (y anteriores) y 2021.11 (y anteriores) de Adobe ColdFusion se ven afectadas por una vulnerabilidad de Cross-Site Scripting (XSS) Reflejada. Si un atacante no autenticado puede convencer a una v\u00edctima para que visite una URL que hace referencia a una p\u00e1gina vulnerable, se puede ejecutar contenido JavaScript malicioso dentro del contexto del navegador de la v\u00edctima.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"psirt@adobe.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"psirt@adobe.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2021\",\"matchCriteriaId\":\"39EBF22C-3ED8-4C91-AA46-1BA920CE1920\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"7A94B406-C011-4673-8C2B-0DD94D46CC4C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"AFD05E3A-10F9-4C75-9710-BA46B66FF6E6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update10:*:*:*:*:*:*\",\"matchCriteriaId\":\"F1FC7D1D-6DD2-48B2-980F-B001B0F24473\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update11:*:*:*:*:*:*\",\"matchCriteriaId\":\"1FA19E1D-61C2-4640-AF06-4BCFE750BDF3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"D57C8681-AC68-47DF-A61E-B5C4B4A47663\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"75608383-B727-48D6-8FFA-D552A338A562\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"7773DB68-414A-4BA9-960F-52471A784379\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"B38B9E86-BCD5-4BCA-8FB7-EC55905184E6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update6:*:*:*:*:*:*\",\"matchCriteriaId\":\"5E7BAB80-8455-4570-A2A2-8F40469EE9CC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update7:*:*:*:*:*:*\",\"matchCriteriaId\":\"F9D645A2-E02D-4E82-A2BD-0A7DE5B8FBCC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update8:*:*:*:*:*:*\",\"matchCriteriaId\":\"6E22D701-B038-4795-AA32-A18BC93C2B6F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2021:update9:*:*:*:*:*:*\",\"matchCriteriaId\":\"CAC4A0EC-C3FC-47D8-86CE-0E6A87A7F0B0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2023:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"B02A37FE-5D31-4892-A3E6-156A8FE62D28\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2023:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"0AA3D302-CFEE-4DFD-AB92-F53C87721BFF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2023:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"EB88D4FE-5496-4639-BAF2-9F29F24ABF29\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2023:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"43E0ED98-2C1F-40B8-AF60-FEB1D85619C0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2023:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"76204873-C6E0-4202-8A03-0773270F1802\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:adobe:coldfusion:2023:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"C1A22BE9-0D47-4BA8-8BDB-9B12D7A0F7C7\"}]}]}],\"references\":[{\"url\":\"https://helpx.adobe.com/security/products/coldfusion/apsb23-52.html\",\"source\":\"psirt@adobe.com\",\"tags\":[\"Release Notes\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.