cve-2024-11013
Vulnerability from cvelistv5
Published
2024-11-29 08:03
Modified
2024-11-29 13:40
Severity ?
EPSS score ?
Summary
Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface.
References
Impacted products
Vendor | Product | Version | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | NEC Corporation | UNIVERGE IX |
Version: from Ver9.2 to Ver10.10.21 |
||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:nec_corporation:univerge_1x:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "univerge_1x", "vendor": "nec_corporation", "versions": [ { "lessThanOrEqual": "10.10.21", "status": "affected", "version": "9.2", "versionType": "custom" }, { "lessThanOrEqual": "10.8.27", "status": "affected", "version": "10.8", "versionType": "custom" }, { "lessThanOrEqual": "10.9.14", "status": "affected", "version": "10.9", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:nec_corporation:univerge_1x-r\\/ix-v:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "univerge_1x-r\\/ix-v", "vendor": "nec_corporation", "versions": [ { "lessThan": "1.2.15", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-11013", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-29T13:34:19.048337Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-29T13:40:11.027Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "UNIVERGE IX", "vendor": "NEC Corporation", "versions": [ { "status": "affected", "version": "from Ver9.2 to Ver10.10.21" } ] }, { "defaultStatus": "unknown", "product": "UNIVERGE IX", "vendor": "NEC Corporation", "versions": [ { "status": "affected", "version": "for Ver10.8 up to Ver10.8.27" } ] }, { "defaultStatus": "unknown", "product": "UNIVERGE IX", "vendor": "NEC Corporation", "versions": [ { "status": "affected", "version": "for Ver10.9 up to Ver10.9.14" } ] }, { "defaultStatus": "unknown", "product": "UNIVERGE IX-R/IX-V", "vendor": "NEC Corporation", "versions": [ { "status": "affected", "version": "Ver1.2.15 and earlier" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "RyotaK of Flatt Security Inc." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface." } ], "value": "Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-29T08:03:07.458Z", "orgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282", "shortName": "NEC" }, "references": [ { "url": "https://https://jpn.nec.com/security-info/secinfo/nv24-009_en.html" } ], "source": { "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282", "assignerShortName": "NEC", "cveId": "CVE-2024-11013", "datePublished": "2024-11-29T08:03:07.458Z", "dateReserved": "2024-11-08T02:59:55.534Z", "dateUpdated": "2024-11-29T13:40:11.027Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-11013\",\"sourceIdentifier\":\"psirt-info@cyber.jp.nec.com\",\"published\":\"2024-11-29T08:15:03.923\",\"lastModified\":\"2024-11-29T08:15:03.923\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface.\"},{\"lang\":\"es\",\"value\":\"La vulnerabilidad de inyecci\u00f3n de comandos en NEC Corporation UNIVERGE IX desde Ver9.2 hasta Ver10.10.21, desde Ver10.8 hasta Ver10.8.27, desde Ver10.9 hasta Ver10.9.14 y UNIVERGE IX-R/IX-V Ver1.2.15 y anteriores permite a un atacante inyectar comandos CLI arbitrarios para que se ejecuten en el dispositivo a trav\u00e9s de la interfaz de administraci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt-info@cyber.jp.nec.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt-info@cyber.jp.nec.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"references\":[{\"url\":\"https://https://jpn.nec.com/security-info/secinfo/nv24-009_en.html\",\"source\":\"psirt-info@cyber.jp.nec.com\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.