CVE-2024-12399 (GCVE-0-2024-12399)
Vulnerability from cvelistv5 – Published: 2025-01-17 09:37 – Updated: 2025-09-09 20:41- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Pro-face GP-Pro EX |
Affected:
all version , < v5.00.100
(version)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12399",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-17T13:19:08.787250Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T16:55:25.689Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Pro-face GP-Pro EX",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v5.00.100",
"status": "affected",
"version": "all version",
"versionType": "version"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Pro-face Remote HMI",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "v1.70.000",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication.\n\n\u003cbr\u003e"
}
],
"value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T20:41:23.793Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-12399",
"datePublished": "2025-01-17T09:37:35.734Z",
"dateReserved": "2024-12-10T09:21:04.278Z",
"dateUpdated": "2025-09-09T20:41:23.793Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-12399",
"date": "2026-04-16",
"epss": "0.00196",
"percentile": "0.41615"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-12399\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2025-01-17T10:15:06.697\",\"lastModified\":\"2025-01-17T10:15:06.697\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\\nman in the middle attack by intercepting the communication.\"},{\"lang\":\"es\",\"value\":\"CWE-924: Existe una vulnerabilidad de aplicaci\u00f3n inadecuada de la integridad del mensaje durante la transmisi\u00f3n en un canal de comunicaci\u00f3n que podr\u00eda causar una p\u00e9rdida parcial de confidencialidad, p\u00e9rdida de integridad y disponibilidad de la HMI cuando el atacante realiza un ataque man in the middle interceptando la comunicaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"PASSIVE\",\"vulnConfidentialityImpact\":\"LOW\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":5.5}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-924\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf\",\"source\":\"cybersecurity@se.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-12399\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-17T13:19:08.787250Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-12T16:55:05.827Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 6.1, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"PASSIVE\", \"attackComplexity\": \"HIGH\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"LOW\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"Pro-face GP-Pro EX\", \"versions\": [{\"status\": \"affected\", \"version\": \"all version\", \"lessThan\": \"v5.00.100\", \"versionType\": \"version\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Pro-face Remote HMI\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\", \"lessThan\": \"v1.70.000\", \"versionType\": \"version\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\\nman in the middle attack by intercepting the communication.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\\nman in the middle attack by intercepting the communication.\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-924\", \"description\": \"CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2025-09-09T20:41:23.793Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-12399\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-09T20:41:23.793Z\", \"dateReserved\": \"2024-12-10T09:21:04.278Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2025-01-17T09:37:35.734Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
SEVD-2025-014-02
Vulnerability from csaf_se - Published: 2025-01-14 00:00 - Updated: 2025-09-09 04:00CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs man in the middle attack by intercepting the communication.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n\nFor more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\nFor further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its Pro-face GP-Pro EX and Remote HMI products. \r\n\nThe Pro-face [GP-Pro EX](https://www.proface.com/en/product/soft/gpproex/top) product is HMI Screen Editor \u0026 Logic Programming Software. \r\n\nThe Pro-face [Remote HMI](https://www.proface.com/en/product/soft/remotehmi/top) product is a remote monitoring software for mobile and allows you to check \r\nequipment information on a tablet or smartphone. \r\n\nFailure to apply the mitigations provided below may risk Man-in-the-Middle attacks which could result in \r\ninformation disclosure, integrity issues and operational failures. ",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 ([CVSS v4.0](https://www.first.org/cvss/calculator/4.0)). CVSS v3.1 \nwill be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without \nincorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score \nthe CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as \nthe presence of mitigations in that environment. Environmental metrics may refine the relative severity posed \nby the vulnerabilities described in this document within a customer\u2019s environment."
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We \nstrongly recommend the use of back-ups and evaluating the impact of these patches in a Test and \nDevelopment environment or on an offline infrastructure. Contact Schneider Electric\u0027s [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp) if you need assistance removing a patch. "
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Pro-face GP-Pro EX and Remote HMI - SEVD-2025-014-02 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
},
{
"category": "self",
"summary": "Pro-face GP-Pro EX and Remote HMI - SEVD-2025-014-02 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-014-02.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Pro-face GP-Pro EX and Remote HMI",
"tracking": {
"current_release_date": "2025-09-09T04:00:00.000Z",
"generator": {
"date": "2025-09-06T13:00:16.211Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2025-014-02",
"initial_release_date": "2025-01-14T00:00:00.000Z",
"revision_history": [
{
"date": "2025-01-14T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2025-09-09T04:00:00.000Z",
"number": "2.0.0",
"summary": "Remediations are now available for Pro-face GP-Pro EX and Pro-face Remote HMI."
}
],
"status": "final",
"version": "2.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.00.100",
"product": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 5.00.100",
"product_id": "1"
}
},
{
"category": "product_version",
"name": "5.00.100",
"product": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 5.00.100",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "GP-Pro EX"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.70.000",
"product": {
"name": "Schneider Electric Pro-face Remote HMI Versions prior to 1.70.000",
"product_id": "2"
}
},
{
"category": "product_version",
"name": "1.70.000",
"product": {
"name": "Schneider Electric Pro-face Remote HMI Version 1.70.000",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Remote HMI"
}
],
"category": "product_family",
"name": "Pro-face"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Haichuan Xu"
],
"organization": "Georgia Institute of Technology"
}
],
"cve": "CVE-2024-12399",
"cwe": {
"id": "CWE-924",
"name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel"
},
"notes": [
{
"category": "description",
"text": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel\r\nvulnerability exists that could cause partial loss of confidentiality, loss of integrity and availability of the \r\nHMI when attacker performs man in the middle attack by intercepting the communication.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"4"
],
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 5.00.100 release of GP-ProEX includes a fix for this vulnerability. Please contact your [Pro-face Customer Care Center](https://www.proface.com/en/contact) to obtain the fix.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 1.70.000 of Pro-face Remote HMI includes a fix for this vulnerability and is available for download in [Apple App Store](https://apps.apple.com/) and [Google Play Store](https://play.google.com/).",
"product_ids": [
"2"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \n\nFor customers requiring the use of Pro-face Remote HMI, Schneider Electric recommends using following mitigations:\n\n* Use of [Pro-face Connect solution](https://www.proface.com/en/product/soft/proface_connect/top) or any other VPN solutions for securing the remote access by encrypting the communication between Pro-face Remote HMI and Pro-face GP-ProEX.\n\n* Always connect the products to only trusted networks and follow the [Pro-face Cybersecurity Guidelines](https://www.proface.com/en/download/manual/cybersecurity_guide)\n\n* Set up a connection password. For more details refer to the [GP-Pro EX V4.0 Reference Manual](https://www.pro-face.com/otasuke/files/manual/gpproex/new/refer/gpproex.htm#t=mergedProjects%2Fremote%2Fremote_sg_remotehmi.htm\u0026rhsearch=Remote%20HMI\u0026rhhlterm=Remote%20HMI\u0026ux=search) in section \u201cRemote Viewer - Pro-face Remote HMI\u201d \n\nFor customers not using the Pro-face Remote HMI Schneider Electric recommends using following mitigations to reduce the risk of exploit:\n\n* Disable the Pro-face Remote HMI feature (deactivated by default). For more details refer to the [GP-Pro EX V4.0 Reference Manual](https://www.pro-face.com/otasuke/files/manual/gpproex/new/refer/gpproex.htm#t=mergedProjects%2Fmaintenance%2Fmaintenance_sg_remotemonitor.htm%23BMK_ProfaceRemoteHMI\u0026rhsearch=Remote%20HMI) section \u201cPro-face Remote HMI Settings\u201d",
"product_ids": [
"1",
"2"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2024-12399"
}
]
}
FKIE_CVE-2024-12399
Vulnerability from fkie_nvd - Published: 2025-01-17 10:15 - Updated: 2026-04-15 00:35| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication."
},
{
"lang": "es",
"value": "CWE-924: Existe una vulnerabilidad de aplicaci\u00f3n inadecuada de la integridad del mensaje durante la transmisi\u00f3n en un canal de comunicaci\u00f3n que podr\u00eda causar una p\u00e9rdida parcial de confidencialidad, p\u00e9rdida de integridad y disponibilidad de la HMI cuando el atacante realiza un ataque man in the middle interceptando la comunicaci\u00f3n."
}
],
"id": "CVE-2024-12399",
"lastModified": "2026-04-15T00:35:42.020",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.6,
"impactScore": 5.5,
"source": "cybersecurity@se.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
},
"published": "2025-01-17T10:15:06.697",
"references": [
{
"source": "cybersecurity@se.com",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-924"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
CERTFR-2025-AVI-0034
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | BMXNOE0110 toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | Modicon M580/Quantum communication modules BMXCRA BMXCRA31200 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | EcoStruxureTM Control Expert Asset Link versions antérieures à 4.0 SP1 pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon Quantum communication modules 140CRA 140CRA31200 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | Modicon M340 processors (part numbers BMXP34*) toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | EcoStruxureTM Machine SCADA Expert Asset Link toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Pro-face GP-Pro EX toutes versions pour la vulnérabilité CVE-2024-12399 | ||
| Schneider Electric | N/A | BMENOR2200H toutes versions pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | EcoStruxure OPC UA Server Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | EcoStruxureTM Process Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Pro-face Remote HMI toutes versions pour la vulnérabilité CVE-2024-12399 | ||
| Schneider Electric | N/A | EcoStruxureTM Control Expert versions antérieures à 16.1 | ||
| Schneider Electric | N/A | EcoStruxure Machine Expert including EcoStruxureTM Machine Expert Safety toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | EVLink Pro AC versions antérieures à 1.3.10 | ||
| Schneider Electric | N/A | Modicon M580 CPU (part numbers BMEP* et BMEH*, excluding M580 CPU Safety) versions antérieures à 4.30 pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | EcoStruxure Machine Expert Twin toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | BMXNOR0200H versions antérieures à 1.70IR26 | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580/Quantum communication modules BMXCRA BMXCRA31210 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | BMXNOE0100 toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | Vijeo Designer toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580 CPU Safety (part numbers BMEP58*S et BMEH58*S) versions antérieures à 4.21 pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | Zelio Soft 2 toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580 communication modules BMENOC BMENOC0321 versions antérieures à 1.10 | ||
| Schneider Electric | N/A | EcoStruxure Architecture Builder versions antérieures à 7.0.18 | ||
| Schneider Electric | N/A | Modicon Quantum communication modules 140CRA 140CRA31908 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | Modicon M580 communication modules BMECRA BMECRA31210 toutes versions pour la vulnérabilité CVE-2021-29999 |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "BMXNOE0110 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580/Quantum communication modules BMXCRA BMXCRA31200 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Control Expert Asset Link versions ant\u00e9rieures \u00e0 4.0 SP1 pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum communication modules 140CRA 140CRA31200 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 processors (part numbers BMXP34*) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Machine SCADA Expert Asset Link toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face GP-Pro EX toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12399",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMENOR2200H toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure OPC UA Server Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Process Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face Remote HMI toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12399",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Control Expert versions ant\u00e9rieures \u00e0 16.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Machine Expert including EcoStruxureTM Machine Expert Safety toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EVLink Pro AC versions ant\u00e9rieures \u00e0 1.3.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 CPU (part numbers BMEP* et BMEH*, excluding M580 CPU Safety) versions ant\u00e9rieures \u00e0 4.30 pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Machine Expert Twin toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOR0200H versions ant\u00e9rieures \u00e0 1.70IR26",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580/Quantum communication modules BMXCRA BMXCRA31210 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOE0100 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Vijeo Designer toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 CPU Safety (part numbers BMEP58*S et BMEH58*S) versions ant\u00e9rieures \u00e0 4.21 pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Zelio Soft 2 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 communication modules BMENOC BMENOC0321 versions ant\u00e9rieures \u00e0 1.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Architecture Builder versions ant\u00e9rieures \u00e0 7.0.18",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum communication modules 140CRA 140CRA31908 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 communication modules BMECRA BMECRA31210 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-12399",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12399"
},
{
"name": "CVE-2024-11139",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-11139"
},
{
"name": "CVE-2021-29999",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29999"
},
{
"name": "CVE-2024-11425",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-11425"
},
{
"name": "CVE-2024-2658",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2658"
},
{
"name": "CVE-2024-12142",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12142"
}
],
"links": [],
"reference": "CERTFR-2025-AVI-0034",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-01-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-09",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-09\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-09.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-03.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-07",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-07.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-05",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-05.pdf"
}
]
}
CERTFR-2025-AVI-0034
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | BMXNOE0110 toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | Modicon M580/Quantum communication modules BMXCRA BMXCRA31200 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | EcoStruxureTM Control Expert Asset Link versions antérieures à 4.0 SP1 pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon Quantum communication modules 140CRA 140CRA31200 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | Modicon M340 processors (part numbers BMXP34*) toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | EcoStruxureTM Machine SCADA Expert Asset Link toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Pro-face GP-Pro EX toutes versions pour la vulnérabilité CVE-2024-12399 | ||
| Schneider Electric | N/A | BMENOR2200H toutes versions pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | EcoStruxure OPC UA Server Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | EcoStruxureTM Process Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Pro-face Remote HMI toutes versions pour la vulnérabilité CVE-2024-12399 | ||
| Schneider Electric | N/A | EcoStruxureTM Control Expert versions antérieures à 16.1 | ||
| Schneider Electric | N/A | EcoStruxure Machine Expert including EcoStruxureTM Machine Expert Safety toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | EVLink Pro AC versions antérieures à 1.3.10 | ||
| Schneider Electric | N/A | Modicon M580 CPU (part numbers BMEP* et BMEH*, excluding M580 CPU Safety) versions antérieures à 4.30 pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | EcoStruxure Machine Expert Twin toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | BMXNOR0200H versions antérieures à 1.70IR26 | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580/Quantum communication modules BMXCRA BMXCRA31210 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | BMXNOE0100 toutes versions pour la vulnérabilité CVE-2024-12142 | ||
| Schneider Electric | N/A | Vijeo Designer toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580 CPU Safety (part numbers BMEP58*S et BMEH58*S) versions antérieures à 4.21 pour la vulnérabilité CVE-2024-11425 | ||
| Schneider Electric | N/A | Zelio Soft 2 toutes versions pour la vulnérabilité CVE-2024-2658 | ||
| Schneider Electric | N/A | Modicon M580 communication modules BMENOC BMENOC0321 versions antérieures à 1.10 | ||
| Schneider Electric | N/A | EcoStruxure Architecture Builder versions antérieures à 7.0.18 | ||
| Schneider Electric | N/A | Modicon Quantum communication modules 140CRA 140CRA31908 toutes versions pour la vulnérabilité CVE-2021-29999 | ||
| Schneider Electric | N/A | Modicon M580 communication modules BMECRA BMECRA31210 toutes versions pour la vulnérabilité CVE-2021-29999 |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "BMXNOE0110 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580/Quantum communication modules BMXCRA BMXCRA31200 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Control Expert Asset Link versions ant\u00e9rieures \u00e0 4.0 SP1 pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum communication modules 140CRA 140CRA31200 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 processors (part numbers BMXP34*) toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Machine SCADA Expert Asset Link toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face GP-Pro EX toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12399",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMENOR2200H toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure OPC UA Server Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Process Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face Remote HMI toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12399",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxureTM Control Expert versions ant\u00e9rieures \u00e0 16.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Machine Expert including EcoStruxureTM Machine Expert Safety toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EVLink Pro AC versions ant\u00e9rieures \u00e0 1.3.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 CPU (part numbers BMEP* et BMEH*, excluding M580 CPU Safety) versions ant\u00e9rieures \u00e0 4.30 pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Machine Expert Twin toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOR0200H versions ant\u00e9rieures \u00e0 1.70IR26",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580/Quantum communication modules BMXCRA BMXCRA31210 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOE0100 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-12142",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Vijeo Designer toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 CPU Safety (part numbers BMEP58*S et BMEH58*S) versions ant\u00e9rieures \u00e0 4.21 pour la vuln\u00e9rabilit\u00e9 CVE-2024-11425",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Zelio Soft 2 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2024-2658",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 communication modules BMENOC BMENOC0321 versions ant\u00e9rieures \u00e0 1.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Architecture Builder versions ant\u00e9rieures \u00e0 7.0.18",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum communication modules 140CRA 140CRA31908 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 communication modules BMECRA BMECRA31210 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2021-29999",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-12399",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12399"
},
{
"name": "CVE-2024-11139",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-11139"
},
{
"name": "CVE-2021-29999",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29999"
},
{
"name": "CVE-2024-11425",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-11425"
},
{
"name": "CVE-2024-2658",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2658"
},
{
"name": "CVE-2024-12142",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-12142"
}
],
"links": [],
"reference": "CERTFR-2025-AVI-0034",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-01-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-09",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-09\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-09.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-03.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-07",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-07.pdf"
},
{
"published_at": "2025-01-14",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-014-05",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-05.pdf"
}
]
}
GHSA-5Q3J-G5R8-6RFG
Vulnerability from github – Published: 2025-01-17 12:30 – Updated: 2025-01-17 12:30CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs man in the middle attack by intercepting the communication.
{
"affected": [],
"aliases": [
"CVE-2024-12399"
],
"database_specific": {
"cwe_ids": [
"CWE-924"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-01-17T10:15:06Z",
"severity": "MODERATE"
},
"details": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability\nexists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs\nman in the middle attack by intercepting the communication.",
"id": "GHSA-5q3j-g5r8-6rfg",
"modified": "2025-01-17T12:30:40Z",
"published": "2025-01-17T12:30:40Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-12399"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
"type": "CVSS_V3"
},
{
"score": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
ICSA-25-035-07
Vulnerability from csaf_cisa - Published: 2025-01-14 00:00 - Updated: 2025-09-09 04:00CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause partial loss of confidentiality, loss of integrity and availability of the HMI when attacker performs man in the middle attack by intercepting the communication.
{
"document": {
"acknowledgments": [
{
"organization": "Schneider Electric CPCERT",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n\nFor more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\nFor further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its Pro-face GP-Pro EX and Remote HMI products. \r\n\nThe Pro-face [GP-Pro EX](https://www.proface.com/en/product/soft/gpproex/top) product is HMI Screen Editor \u0026 Logic Programming Software. \r\n\nThe Pro-face [Remote HMI](https://www.proface.com/en/product/soft/remotehmi/top) product is a remote monitoring software for mobile and allows you to check \r\nequipment information on a tablet or smartphone. \r\n\nFailure to apply the mitigations provided below may risk Man-in-the-Middle attacks which could result in \r\ninformation disclosure, integrity issues and operational failures. ",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 ([CVSS v4.0](https://www.first.org/cvss/calculator/4.0)). CVSS v3.1 \nwill be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without \nincorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score \nthe CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as \nthe presence of mitigations in that environment. Environmental metrics may refine the relative severity posed \nby the vulnerabilities described in this document within a customer\u2019s environment."
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We \nstrongly recommend the use of back-ups and evaluating the impact of these patches in a Test and \nDevelopment environment or on an offline infrastructure. Contact Schneider Electric\u0027s [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp) if you need assistance removing a patch. "
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2025-014-02 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "Pro-face GP-Pro EX and Remote HMI - SEVD-2025-014-02 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-014-02.json"
},
{
"category": "self",
"summary": "Pro-face GP-Pro EX and Remote HMI - SEVD-2025-014-02 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-02.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-035-07 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-035-07.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-035-07 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-035-07"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Schneider Electric Pro-face GP-Pro EX and Remote HMI (Update A)",
"tracking": {
"current_release_date": "2025-09-09T04:00:00.000000Z",
"generator": {
"date": "2025-10-21T18:53:29.163497Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-035-07",
"initial_release_date": "2025-01-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2025-01-14T00:00:00.000000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2025-09-09T04:00:00.000000Z",
"number": "2.0.0",
"summary": "Remediations are now available for Pro-face GP-Pro EX and Pro-face Remote HMI."
}
],
"status": "final",
"version": "2.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.00.100",
"product": {
"name": "Schneider Electric Pro-face GP-Pro EX Versions prior to 5.00.100",
"product_id": "CSAFPID-0001"
}
},
{
"category": "product_version",
"name": "5.00.100",
"product": {
"name": "Schneider Electric Pro-face GP-Pro EX Version 5.00.100",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "GP-Pro EX"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c1.70.000",
"product": {
"name": "Schneider Electric Pro-face Remote HMI Versions prior to 1.70.000",
"product_id": "CSAFPID-0003"
}
},
{
"category": "product_version",
"name": "1.70.000",
"product": {
"name": "Schneider Electric Pro-face Remote HMI Version 1.70.000",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "Remote HMI"
}
],
"category": "product_family",
"name": "Pro-face"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Haichuan Xu"
],
"organization": "Georgia Institute of Technology"
}
],
"cve": "CVE-2024-12399",
"cwe": {
"id": "CWE-924",
"name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel"
},
"notes": [
{
"category": "description",
"text": "CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel\r\nvulnerability exists that could cause partial loss of confidentiality, loss of integrity and availability of the \r\nHMI when attacker performs man in the middle attack by intercepting the communication.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002",
"CSAFPID-0004"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 5.00.100 release of GP-ProEX includes a fix for this vulnerability. Please contact your [Pro-face Customer Care Center](https://www.proface.com/en/contact) to obtain the fix.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Version 1.70.000 of Pro-face Remote HMI includes a fix for this vulnerability and is available for download in [Apple App Store](https://apps.apple.com/) and [Google Play Store](https://play.google.com/).",
"product_ids": [
"CSAFPID-0003"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \n\nFor customers requiring the use of Pro-face Remote HMI, Schneider Electric recommends using following mitigations:\n\n* Use of [Pro-face Connect solution](https://www.proface.com/en/product/soft/proface_connect/top) or any other VPN solutions for securing the remote access by encrypting the communication between Pro-face Remote HMI and Pro-face GP-ProEX.\n\n* Always connect the products to only trusted networks and follow the [Pro-face Cybersecurity Guidelines](https://www.proface.com/en/download/manual/cybersecurity_guide)\n\n* Set up a connection password. For more details refer to the [GP-Pro EX V4.0 Reference Manual](https://www.pro-face.com/otasuke/files/manual/gpproex/new/refer/gpproex.htm#t=mergedProjects%2Fremote%2Fremote_sg_remotehmi.htm\u0026rhsearch=Remote%20HMI\u0026rhhlterm=Remote%20HMI\u0026ux=search) in section \u201cRemote Viewer - Pro-face Remote HMI\u201d \n\nFor customers not using the Pro-face Remote HMI Schneider Electric recommends using following mitigations to reduce the risk of exploit:\n\n* Disable the Pro-face Remote HMI feature (deactivated by default). For more details refer to the [GP-Pro EX V4.0 Reference Manual](https://www.pro-face.com/otasuke/files/manual/gpproex/new/refer/gpproex.htm#t=mergedProjects%2Fmaintenance%2Fmaintenance_sg_remotemonitor.htm%23BMK_ProfaceRemoteHMI\u0026rhsearch=Remote%20HMI) section \u201cPro-face Remote HMI Settings\u201d",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2024-12399"
}
]
}
BDU:2025-00556
Vulnerability from fstec - Published: 10.12.2024{
"CVSS 2.0": "AV:N/AC:H/Au:N/C:P/I:C/A:C",
"CVSS 3.0": "AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
"CVSS 4.0": "AV:N/AC:H/AT:N/PR:N/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N",
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "- (Pro-Face GP-Pro EX), - (Pro-face Remote HMI)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-06.pdf\n\n\u041a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043c\u0435\u0440\u044b:\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432 \u043c\u0435\u0436\u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0443\u0434\u0430\u043b\u0451\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430;\n- \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0435\u0442\u0438 \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u043c\u0443 \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0443 \u0438\u0437 \u0434\u0440\u0443\u0433\u0438\u0445 \u043f\u043e\u0434\u0441\u0435\u0442\u0435\u0439;\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u0438\u0437 \u0432\u043d\u0435\u0448\u043d\u0438\u0445 \u0441\u0435\u0442\u0435\u0439 (\u0418\u043d\u0442\u0435\u0440\u043d\u0435\u0442);\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439 \u0434\u043b\u044f \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 (VPN);\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u043f\u0430\u0440\u043e\u043b\u044f \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f (\u0431\u043e\u043b\u0435\u0435 \u043f\u043e\u0434\u0440\u043e\u0431\u043d\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u0432 \u0441\u043f\u0440\u0430\u0432\u043e\u0447\u043d\u043e\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 GP-Pro EX V4.0 \u0432 \u0440\u0430\u0437\u0434\u0435\u043b\u0435 \u00abRemote Viewer - Pro-face Remote HMI\u00bb:\nhttps://www.pro-face.com/otasuke/files/manual/gpproex/new/refer/gpproex.htm#t=mergedProjects%2Fremote%2Fremote_sg_remotehmi.htm\u0026rhsearch=Remote%20HMI\u0026rhhlterm=Remote%20HMI\u0026ux=search);\n- \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438 Pro-face Remote HMI (\u0431\u043e\u043b\u0435\u0435 \u043f\u043e\u0434\u0440\u043e\u0431\u043d\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u0432 \u0441\u043f\u0440\u0430\u0432\u043e\u0447\u043d\u043e\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 GP-Pro EX V4.0 \u0432 \u0440\u0430\u0437\u0434\u0435\u043b\u0435 \u00ab\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 Pro-face Remote HMI\u00bb: https://www.pro-face.com/otasuke/files/manual/gpproex/new/refer/gpproex.htm#t=mergedProjects%2Fremote%2Fremote_sg_remotehmi.htm\u0026rhsearch=Remote%20HMI\u0026rhhlterm=Remote%20HMI\u0026ux=search).",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "10.12.2024",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "13.08.2025",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "21.01.2025",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2025-00556",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2024-12399",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u0435\u0442",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u044b",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Pro-Face GP-Pro EX, Pro-face Remote HMI",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043c\u043d\u043e\u0433\u043e\u043a\u043e\u043d\u0442\u0443\u0440\u043d\u043e\u0433\u043e \u0438\u0437\u043c\u0435\u0440\u0438\u0442\u0435\u043b\u044f \u044d\u043b\u0435\u043a\u0442\u0440\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f PowerLogic HDPM6000, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435\u043c \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u0438 \u0441\u043e\u043e\u0431\u0449\u0435\u043d\u0438\u0439 \u043f\u0440\u0438 \u0438\u0445 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0435 \u043f\u043e \u043a\u0430\u043d\u0430\u043b\u0443 \u0441\u0432\u044f\u0437\u0438, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043f\u043e\u0432\u044b\u0441\u0438\u0442\u044c \u0441\u0432\u043e\u0438 \u043f\u0440\u0438\u0432\u0438\u043b\u0435\u0433\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0430\u044f \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u044f \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u0438 \u0441\u043e\u043e\u0431\u0449\u0435\u043d\u0438\u0439 \u043f\u0440\u0438 \u0438\u0445 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0435 \u0432 \u043a\u0430\u043d\u0430\u043b \u0441\u0432\u044f\u0437\u0438 (CWE-924)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u0441\u043e\u0437\u0434\u0430\u043d\u0438\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u0438 Pro-Face GP-Pro EX \u0438 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c Pro-face Remote HMI \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0438\u0435\u043c \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u0438 \u0441\u043e\u043e\u0431\u0449\u0435\u043d\u0438\u0439 \u043f\u0440\u0438 \u0438\u0445 \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0435 \u043f\u043e \u043a\u0430\u043d\u0430\u043b\u0443 \u0441\u0432\u044f\u0437\u0438. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0440\u0435\u0430\u043b\u0438\u0437\u043e\u0432\u0430\u0442\u044c \u0430\u0442\u0430\u043a\u0443 \u0442\u0438\u043f\u0430 \u00ab\u0447\u0435\u043b\u043e\u0432\u0435\u043a \u043f\u043e\u0441\u0435\u0440\u0435\u0434\u0438\u043d\u0435\u00bb",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041f\u043e\u0434\u043c\u0435\u043d\u0430 \u043f\u0440\u0438 \u0432\u0437\u0430\u0438\u043c\u043e\u0434\u0435\u0439\u0441\u0442\u0432\u0438\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-06.pdf\nhttps://vuldb.com/?id.292437",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u0421\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-924",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,3)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,1)\n\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 4.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 6,1)"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.