cve-2024-20460
Vulnerability from cvelistv5
Published
2024-10-16 16:16
Modified
2024-10-16 18:24
Summary
Cisco ATA 190 Series Analog Telephone Adapter Firmware Reflected Cross-Site Scripting Vulnerability
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-20460",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-16T18:14:44.675241Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-16T18:24:23.586Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Cisco Analog Telephone Adaptor (ATA) Software",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "12.0.1 SR2"
            },
            {
              "status": "affected",
              "version": "11.1.0"
            },
            {
              "status": "affected",
              "version": "12.0.1 SR1"
            },
            {
              "status": "affected",
              "version": "11.1.0 MSR1"
            },
            {
              "status": "affected",
              "version": "12.0.1"
            },
            {
              "status": "affected",
              "version": "11.1.0 MSR2"
            },
            {
              "status": "affected",
              "version": "11.1.0 MSR3"
            },
            {
              "status": "affected",
              "version": "11.1.0 MSR4"
            },
            {
              "status": "affected",
              "version": "12.0.1 SR3"
            },
            {
              "status": "affected",
              "version": "11.2.1"
            },
            {
              "status": "affected",
              "version": "12.0.1 SR4"
            },
            {
              "status": "affected",
              "version": "11.2.2"
            },
            {
              "status": "affected",
              "version": "11.2.2 MSR1"
            },
            {
              "status": "affected",
              "version": "12.0.1 SR5"
            },
            {
              "status": "affected",
              "version": "11.2.3"
            },
            {
              "status": "affected",
              "version": "11.2.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web-based management interface of Cisco ATA 190 Series Analog Telephone Adapter firmware could allow an unauthenticated, remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user.\r\n\r\nThis vulnerability is due to insufficient validation of user input. An attacker could exploit this vulnerability by persuading a user\u0026nbsp;to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information on an affected device."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerabilities that are described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "cvssV3_1"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "cwe"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-16T16:16:23.411Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "cisco-sa-ata19x-multi-RDTEqRsy",
          "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ata19x-multi-RDTEqRsy"
        }
      ],
      "source": {
        "advisory": "cisco-sa-ata19x-multi-RDTEqRsy",
        "defects": [
          "CSCwf28041"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco ATA 190 Series Analog Telephone Adapter Firmware Reflected Cross-Site Scripting Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2024-20460",
    "datePublished": "2024-10-16T16:16:23.411Z",
    "dateReserved": "2023-11-08T15:08:07.680Z",
    "dateUpdated": "2024-10-16T18:24:23.586Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-20460\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2024-10-16T17:15:14.880\",\"lastModified\":\"2024-10-22T18:24:59.710\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based management interface of Cisco ATA 190 Series Analog Telephone Adapter firmware could allow an unauthenticated, remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user.\\r\\n\\r\\nThis vulnerability is due to insufficient validation of user input. An attacker could exploit this vulnerability by persuading a user\u0026nbsp;to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information on an affected device.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz de administraci\u00f3n basada en web del firmware del adaptador telef\u00f3nico anal\u00f3gico Cisco ATA 190 Series podr\u00eda permitir que un atacante remoto no autenticado realice un ataque de cross-site scripting (XSS) reflejado contra un usuario. Esta vulnerabilidad se debe a una validaci\u00f3n insuficiente de la entrada del usuario. Un atacante podr\u00eda aprovechar esta vulnerabilidad persuadiendo a un usuario para que haga clic en un link manipulado. Una explotaci\u00f3n exitosa podr\u00eda permitir al atacante ejecutar c\u00f3digo de secuencia de comandos arbitrario en el contexto de la interfaz afectada o acceder a informaci\u00f3n confidencial basada en el navegador en un dispositivo afectado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-80\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:ata_191_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.0.2\",\"matchCriteriaId\":\"E464918E-6409-4ACC-B27A-ECD7A5A5ABF8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:ata_191:-:*:*:*:on-premises:*:*:*\",\"matchCriteriaId\":\"2BBB1A29-ABF8-4F79-A436-A416FAF4E7A9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:ata_191_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"11.2.5\",\"matchCriteriaId\":\"8FA479CC-10DC-4B3A-A869-7E0CCD02C959\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:ata_191:-:*:*:*:multiplatform:*:*:*\",\"matchCriteriaId\":\"B0C232BB-005C-4E04-9B99-2B01AC8E8BA1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:ata_192_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"11.2.5\",\"matchCriteriaId\":\"7B66D888-565A-4EB1-B19B-594B302AAA72\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:ata_192:-:*:*:*:multiplatform:*:*:*\",\"matchCriteriaId\":\"00A3390F-594D-4DB2-96EC-04D0D73C9421\"}]}]}],\"references\":[{\"url\":\"https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ata19x-multi-RDTEqRsy\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.