cve-2024-2427
Vulnerability from cvelistv5
Published
2024-03-25 20:20
Modified
2024-08-21 14:57
Severity ?
EPSS score ?
Summary
Rockwell Automation - Denial-of-service and Input Validation Vulnerabilities in PowerFlex® 527
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Rockwell Automation | PowerFlex® 527 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:11:53.547Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:rockwellautomation:powerflex_527_ac_drives_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "powerflex_527_ac_drives_firmware", "vendor": "rockwellautomation", "versions": [ { "lessThan": "*", "status": "affected", "version": "2.001.0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2427", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-21T14:54:12.568778Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-21T14:57:19.700Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerFlex\u00ae 527", "vendor": "Rockwell Automation ", "versions": [ { "status": "affected", "version": " v2.001.x \u003c" } ] } ], "datePublic": "2024-03-21T13:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 527 due to improper traffic throttling in the device. If multiple data packets are sent to the device repeatedly the device will crash and require a manual restart to recover.\u003c/span\u003e\n\n" } ], "value": "\nA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 527 due to improper traffic throttling in the device. If multiple data packets are sent to the device repeatedly the device will crash and require a manual restart to recover.\n\n" } ], "impacts": [ { "capecId": "CAPEC-153", "descriptions": [ { "lang": "en", "value": "CAPEC-153 Input Data Manipulation" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-25T20:20:41.295Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003eThere is no fix currently for this vulnerability. Users using the affected software are encouraged to apply risk mitigations and security best practices, where possible.\u003c/p\u003e\u003cul\u003e\u003cli\u003eImplement network segmentation confirming the device is on an isolated network.\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://literature.rockwellautomation.com/idc/groups/literature/documents/um/520-um002_-en-e.pdf\"\u003eDisable the web server\u003c/a\u003e, if not needed. The web server is disabled by default. Disabling this feature is available in v2.001.x and later.\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e" } ], "value": "\nThere is no fix currently for this vulnerability. Users using the affected software are encouraged to apply risk mitigations and security best practices, where possible.\n\n * Implement network segmentation confirming the device is on an isolated network.\n * Disable the web server https://literature.rockwellautomation.com/idc/groups/literature/documents/um/520-um002_-en-e.pdf , if not needed. The web server is disabled by default. Disabling this feature is available in v2.001.x and later.\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \n\n" } ], "source": { "discovery": "INTERNAL" }, "title": "Rockwell Automation - Denial-of-service and Input Validation Vulnerabilities in PowerFlex\u00ae 527", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-2427", "datePublished": "2024-03-25T20:20:41.295Z", "dateReserved": "2024-03-13T14:46:09.865Z", "dateUpdated": "2024-08-21T14:57:19.700Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-2427\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-03-25T21:15:47.660\",\"lastModified\":\"2024-03-26T12:55:05.010\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 527 due to improper traffic throttling in the device. If multiple data packets are sent to the device repeatedly the device will crash and require a manual restart to recover.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de denegaci\u00f3n de servicio en Rockwell Automation PowerFlex\u00ae 527 debido a una limitaci\u00f3n inadecuada del tr\u00e1fico en el dispositivo. Si se env\u00edan varios paquetes de datos al dispositivo repetidamente, el dispositivo fallar\u00e1 y requerir\u00e1 un reinicio manual para recuperarse.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html\",\"source\":\"PSIRT@rockwellautomation.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.