cve-2024-33498
Vulnerability from cvelistv5
Published
2024-05-14 10:03
Modified
2024-08-02 02:36
Summary
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.
Show details on NVD website


{
   containers: {
      adp: [
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "simatic_rtls_locating_manager",
                  vendor: "siemens",
                  versions: [
                     {
                        lessThan: "3.0.1.1",
                        status: "affected",
                        version: "0",
                        versionType: "custom",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-33498",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "partial",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-05-14T12:39:37.190207Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-06-06T17:49:45.592Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T02:36:02.815Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/html/ssa-093430.html",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "SIMATIC RTLS Locating Manager",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V3.0.1.1",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIMATIC RTLS Locating Manager",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V3.0.1.1",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIMATIC RTLS Locating Manager",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V3.0.1.1",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIMATIC RTLS Locating Manager",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V3.0.1.1",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIMATIC RTLS Locating Manager",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V3.0.1.1",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIMATIC RTLS Locating Manager",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V3.0.1.1",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIMATIC RTLS Locating Manager",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V3.0.1.1",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 5.3,
                  baseSeverity: "MEDIUM",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
                  version: "3.1",
               },
            },
            {
               cvssV4_0: {
                  baseScore: 6.9,
                  baseSeverity: "MEDIUM",
                  vectorString: "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-400",
                     description: "CWE-400: Uncontrolled Resource Consumption",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-06-11T14:20:43.420Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-093430.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2024-33498",
      datePublished: "2024-05-14T10:03:02.675Z",
      dateReserved: "2024-04-23T11:08:04.355Z",
      dateUpdated: "2024-08-02T02:36:02.815Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      fkie_nvd: {
         descriptions: "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en SIMATIC RTLS Locating Manager (6GT2780-0DA00) (todas las versiones &lt; V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (todas las versiones &lt; V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (Todas las versiones &lt; V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (Todas las versiones &lt; V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (Todas las versiones &lt; V3 .0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (todas las versiones &lt; V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (todas las versiones &lt; V3.0.1.1). Las aplicaciones afectadas no liberan correctamente la memoria asignada cuando se manejan paquetes entrantes manipulados espec\\u00edficamente. Esto podr\\u00eda permitir que un atacante remoto no autenticado provoque una condici\\u00f3n de denegaci\\u00f3n de servicio al bloquear el servicio cuando se queda sin memoria. El servicio se reinicia autom\\u00e1ticamente despu\\u00e9s de un breve periodo de tiempo.\"}]",
         id: "CVE-2024-33498",
         lastModified: "2024-11-21T09:17:02.157",
         metrics: "{\"cvssMetricV40\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\", \"baseScore\": 6.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"vulnerableSystemConfidentiality\": \"NONE\", \"vulnerableSystemIntegrity\": \"NONE\", \"vulnerableSystemAvailability\": \"LOW\", \"subsequentSystemConfidentiality\": \"NONE\", \"subsequentSystemIntegrity\": \"NONE\", \"subsequentSystemAvailability\": \"NONE\", \"exploitMaturity\": \"NOT_DEFINED\", \"confidentialityRequirements\": \"NOT_DEFINED\", \"integrityRequirements\": \"NOT_DEFINED\", \"availabilityRequirements\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NOT_DEFINED\", \"modifiedAttackComplexity\": \"NOT_DEFINED\", \"modifiedAttackRequirements\": \"NOT_DEFINED\", \"modifiedPrivilegesRequired\": \"NOT_DEFINED\", \"modifiedUserInteraction\": \"NOT_DEFINED\", \"modifiedVulnerableSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedVulnerableSystemIntegrity\": \"NOT_DEFINED\", \"modifiedVulnerableSystemAvailability\": \"NOT_DEFINED\", \"modifiedSubsequentSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedSubsequentSystemIntegrity\": \"NOT_DEFINED\", \"modifiedSubsequentSystemAvailability\": \"NOT_DEFINED\", \"safety\": \"NOT_DEFINED\", \"automatable\": \"NOT_DEFINED\", \"recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\"}}], \"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 1.4}]}",
         published: "2024-05-14T16:17:19.793",
         references: "[{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-093430.html\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-093430.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
         sourceIdentifier: "productcert@siemens.com",
         vulnStatus: "Awaiting Analysis",
         weaknesses: "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-400\"}]}]",
      },
      nvd: "{\"cve\":{\"id\":\"CVE-2024-33498\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-05-14T16:17:19.793\",\"lastModified\":\"2024-11-21T09:17:02.157\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC RTLS Locating Manager (6GT2780-0DA00) (todas las versiones &lt; V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (todas las versiones &lt; V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (Todas las versiones &lt; V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (Todas las versiones &lt; V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (Todas las versiones &lt; V3 .0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (todas las versiones &lt; V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (todas las versiones &lt; V3.0.1.1). Las aplicaciones afectadas no liberan correctamente la memoria asignada cuando se manejan paquetes entrantes manipulados específicamente. Esto podría permitir que un atacante remoto no autenticado provoque una condición de denegación de servicio al bloquear el servicio cuando se queda sin memoria. El servicio se reinicia automáticamente después de un breve periodo de tiempo.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"NONE\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"LOW\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-093430.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-093430.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
      vulnrichment: {
         containers: "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-093430.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T02:36:02.815Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-33498\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-14T12:39:37.190207Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"simatic_rtls_locating_manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.0.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-14T12:39:19.195Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 6.9, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SIMATIC RTLS Locating Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RTLS Locating Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RTLS Locating Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RTLS Locating Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RTLS Locating Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RTLS Locating Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RTLS Locating Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-093430.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-400\", \"description\": \"CWE-400: Uncontrolled Resource Consumption\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2024-06-11T14:20:43.420Z\"}}}",
         cveMetadata: "{\"cveId\": \"CVE-2024-33498\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T02:36:02.815Z\", \"dateReserved\": \"2024-04-23T11:08:04.355Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2024-05-14T10:03:02.675Z\", \"assignerShortName\": \"siemens\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.