CVE-2024-3909 (GCVE-0-2024-3909)
Vulnerability from cvelistv5 – Published: 2024-04-17 11:31 – Updated: 2024-08-01 20:26
VLAI?
Title
Tenda AC500 execCommand formexeCommand stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Credits
yhryhryhr_tu (VulDB User)
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9\\(1307\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3909",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-22T15:10:58.576153Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:31:11.551Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.261145"
},
{
"name": "VDB-261145 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.261145"
},
{
"name": "Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.313804"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC500 2.0.1.9(1307) wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion formexeCommand der Datei /goform/execCommand. Mittels dem Manipulieren des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T11:31:05.865Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.261145"
},
{
"name": "VDB-261145 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.261145"
},
{
"name": "Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.313804"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-17T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-17T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-17T07:53:08.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC500 execCommand formexeCommand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3909",
"datePublished": "2024-04-17T11:31:05.865Z",
"dateReserved": "2024-04-17T05:42:53.219Z",
"dateUpdated": "2024-08-01T20:26:57.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad fue encontrada en Tenda AC500 2.0.1.9(1307) y clasificada como cr\\u00edtica. La funci\\u00f3n formexeCommand del archivo /goform/execCommand es afectada por esta vulnerabilidad. La manipulaci\\u00f3n del argumento cmdinput provoca un desbordamiento de b\\u00fafer en la regi\\u00f3n stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\\u00f3 el identificador VDB-261145. NOTA: Se contact\\u00f3 primeramente con el proveedor sobre esta divulgaci\\u00f3n, pero no respondi\\u00f3 de ninguna manera.\"}]",
"id": "CVE-2024-3909",
"lastModified": "2024-11-21T09:30:40.570",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\", \"baseScore\": 9.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2024-04-17T12:15:07.853",
"references": "[{\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://vuldb.com/?ctiid.261145\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://vuldb.com/?id.261145\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://vuldb.com/?submit.313804\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://vuldb.com/?ctiid.261145\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://vuldb.com/?id.261145\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://vuldb.com/?submit.313804\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-121\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-3909\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2024-04-17T12:15:07.853\",\"lastModified\":\"2025-02-07T01:57:01.643\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad fue encontrada en Tenda AC500 2.0.1.9(1307) y clasificada como cr\u00edtica. La funci\u00f3n formexeCommand del archivo /goform/execCommand es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento cmdinput provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-261145. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\\\(1307\\\\):*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"64192A8B-CC65-44EC-942B-CC16AADF0D69\"}]}]}],\"references\":[{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://vuldb.com/?ctiid.261145\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.261145\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.313804\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://vuldb.com/?ctiid.261145\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.261145\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.313804\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://vuldb.com/?id.261145\", \"name\": \"VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?ctiid.261145\", \"name\": \"VDB-261145 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?submit.313804\", \"name\": \"Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow\", \"tags\": [\"third-party-advisory\", \"x_transferred\"]}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md\", \"tags\": [\"exploit\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T20:26:57.136Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-3909\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-04-22T15:10:58.576153Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\\\(1307\\\\):*:*:*:*:*:*:*\"], \"vendor\": \"tenda\", \"product\": \"ac500_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.0.1.9\\\\(1307\\\\)\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-04-22T15:02:19.170Z\"}}], \"cna\": {\"title\": \"Tenda AC500 execCommand formexeCommand stack-based overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"yhryhryhr_tu (VulDB User)\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\"}}], \"affected\": [{\"vendor\": \"Tenda\", \"product\": \"AC500\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.0.1.9(1307)\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2024-04-17T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2024-04-17T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2024-04-17T07:53:08.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.261145\", \"name\": \"VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.261145\", \"name\": \"VDB-261145 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.313804\", \"name\": \"Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md\", \"tags\": [\"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"In Tenda AC500 2.0.1.9(1307) wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion formexeCommand der Datei /goform/execCommand. Mittels dem Manipulieren des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \\u00fcber das Netzwerk erfolgen. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121 Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2024-04-17T11:31:05.865Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-3909\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T20:26:57.136Z\", \"dateReserved\": \"2024-04-17T05:42:53.219Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2024-04-17T11:31:05.865Z\", \"assignerShortName\": \"VulDB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…