Summary
A vulnerability in /goform/SetNetControlList in the sub_656BC function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ax1806_firmware:1.0.0.1:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ax1806_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.1" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-40414", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-16T18:00:38.880804Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-17T15:46:31.121Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T04:33:11.687Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/Feng-ZZ-pwn/IOT/blob/main/Tenda%20AX_1806/2/SetNetControlList.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability in /goform/SetNetControlList in the sub_656BC function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-15T16:51:03.816361", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Feng-ZZ-pwn/IOT/blob/main/Tenda%20AX_1806/2/SetNetControlList.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-40414", "datePublished": "2024-07-15T00:00:00", "dateReserved": "2024-07-05T00:00:00", "dateUpdated": "2024-08-02T04:33:11.687Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-40414\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2024-07-15T17:15:02.783\",\"lastModified\":\"2024-08-07T22:13:50.937\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in /goform/SetNetControlList in the sub_656BC function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en /goform/SetNetControlList en la funci\u00f3n sub_656BC en el firmware Tenda AX1806 1.0.0.1 provoca un desbordamiento del b\u00fafer basado en pila.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.6,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":2.8,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:ax1806_firmware:1.0.0.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"578F9769-EF24-4B52-83D3-9AA2C91A503D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:ax1806:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ACA44369-A513-474F-8DD0-A81B598F5B07\"}]}]}],\"references\":[{\"url\":\"https://github.com/Feng-ZZ-pwn/IOT/blob/main/Tenda%20AX_1806/2/SetNetControlList.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Broken Link\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.