CVE-2024-4115 (GCVE-0-2024-4115)
Vulnerability from cvelistv5 – Published: 2024-04-24 15:31 – Updated: 2024-08-01 20:33
VLAI?
Title
Tenda W15E AddDnsForward formAddDnsForward stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
8.8 (High)
8.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Credits
wxhwxhwxh_tutu (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4115",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-26T18:33:54.746492Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:55:26.417Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:33:52.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-261858 | Tenda W15E AddDnsForward formAddDnsForward stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.261858"
},
{
"name": "VDB-261858 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.261858"
},
{
"name": "Submit #317818 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.317818"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formAddDnsForward.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "W15E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.11.0.14"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda W15E 15.11.0.14 gefunden. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formAddDnsForward der Datei /goform/AddDnsForward. Durch die Manipulation des Arguments DnsForwardRule mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-24T15:31:05.160Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-261858 | Tenda W15E AddDnsForward formAddDnsForward stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.261858"
},
{
"name": "VDB-261858 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.261858"
},
{
"name": "Submit #317818 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.317818"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formAddDnsForward.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-24T10:24:44.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W15E AddDnsForward formAddDnsForward stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-4115",
"datePublished": "2024-04-24T15:31:05.160Z",
"dateReserved": "2024-04-24T08:18:56.429Z",
"dateUpdated": "2024-08-01T20:33:52.396Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad fue encontrada en Tenda W15E 15.11.0.14 y clasificada como cr\\u00edtica. La funci\\u00f3n formAddDnsForward del fichero /goform/AddDnsForward es afectada por la vulnerabilidad. La manipulaci\\u00f3n del argumento DnsForwardRule provoca un desbordamiento de b\\u00fafer en la regi\\u00f3n stack de la memoria. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\\u00fablico y puede utilizarse. VDB-261858 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\\u00f3 primeramente con el proveedor sobre esta divulgaci\\u00f3n, pero no respondi\\u00f3 de ninguna manera.\"}]",
"id": "CVE-2024-4115",
"lastModified": "2024-11-21T09:42:12.977",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\", \"baseScore\": 9.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2024-04-24T16:15:10.097",
"references": "[{\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formAddDnsForward.md\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://vuldb.com/?ctiid.261858\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://vuldb.com/?id.261858\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://vuldb.com/?submit.317818\", \"source\": \"cna@vuldb.com\"}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formAddDnsForward.md\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://vuldb.com/?ctiid.261858\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://vuldb.com/?id.261858\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://vuldb.com/?submit.317818\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-121\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-4115\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2024-04-24T16:15:10.097\",\"lastModified\":\"2025-01-15T18:42:08.110\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad fue encontrada en Tenda W15E 15.11.0.14 y clasificada como cr\u00edtica. La funci\u00f3n formAddDnsForward del fichero /goform/AddDnsForward es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento DnsForwardRule provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-261858 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DBEDB6F7-0043-491C-919E-23C8DA89256A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"248A1A83-1288-42D8-A9BC-13D3AA7A2881\"}]}]}],\"references\":[{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formAddDnsForward.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.261858\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.261858\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.317818\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formAddDnsForward.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.261858\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.261858\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.317818\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://vuldb.com/?id.261858\", \"name\": \"VDB-261858 | Tenda W15E AddDnsForward formAddDnsForward stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?ctiid.261858\", \"name\": \"VDB-261858 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?submit.317818\", \"name\": \"Submit #317818 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow\", \"tags\": [\"third-party-advisory\", \"x_transferred\"]}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formAddDnsForward.md\", \"tags\": [\"exploit\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T20:33:52.396Z\"}}, {\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-4115\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-04-26T18:33:54.746492Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-04-26T18:34:29.747Z\"}, \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"title\": \"Tenda W15E AddDnsForward formAddDnsForward stack-based overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"wxhwxhwxh_tutu (VulDB User)\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\"}}], \"affected\": [{\"vendor\": \"Tenda\", \"product\": \"W15E\", \"versions\": [{\"status\": \"affected\", \"version\": \"15.11.0.14\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2024-04-24T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2024-04-24T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2024-04-24T10:24:44.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.261858\", \"name\": \"VDB-261858 | Tenda W15E AddDnsForward formAddDnsForward stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.261858\", \"name\": \"VDB-261858 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.317818\", \"name\": \"Submit #317818 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formAddDnsForward.md\", \"tags\": [\"exploit\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"Es wurde eine Schwachstelle in Tenda W15E 15.11.0.14 gefunden. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formAddDnsForward der Datei /goform/AddDnsForward. Durch die Manipulation des Arguments DnsForwardRule mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \\u00fcber das Netzwerk erfolgen. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121 Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2024-04-24T15:31:05.160Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-4115\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T20:33:52.396Z\", \"dateReserved\": \"2024-04-24T08:18:56.429Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2024-04-24T15:31:05.160Z\", \"assignerShortName\": \"VulDB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…