cve-2024-42425
Vulnerability from cvelistv5
Published
2024-09-10 08:17
Modified
2024-09-10 15:08
Summary
Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-42425",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-10T15:08:42.622659Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-10T15:08:54.037Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell Precision Rack BIOS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.22.1",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-09-05T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
            }
          ],
          "value": "Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-788",
              "description": "CWE-788: Access of Memory Location After End of Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T08:17:04.690Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000227015/dsa-2024-328"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-42425",
    "datePublished": "2024-09-10T08:17:04.690Z",
    "dateReserved": "2024-08-01T07:28:53.702Z",
    "dateUpdated": "2024-09-10T15:08:54.037Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:precision_7920_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.22.1\", \"matchCriteriaId\": \"BC189661-C4D5-4711-B34A-472F81F2A134\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:precision_7920:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0BCCF11B-05BD-4E70-AD26-6B26A7E701FA\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:7920_xl_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.22.1\", \"matchCriteriaId\": \"19274738-5950-4F0C-B721-5668789F5453\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:7920_xl:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F2BB0803-F5C9-4D65-8462-971BCB19B824\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.\"}, {\"lang\": \"es\", \"value\": \"Las versiones de BIOS de Intel para Dell Precision Rack 14G anteriores a la 2.22.2 contienen una vulnerabilidad de acceso a la ubicaci\\u00f3n de la memoria despu\\u00e9s del final del b\\u00fafer. Un atacante con pocos privilegios y acceso local podr\\u00eda aprovechar esta vulnerabilidad, lo que provocar\\u00eda la divulgaci\\u00f3n de informaci\\u00f3n.\"}]",
      "id": "CVE-2024-42425",
      "lastModified": "2024-09-16T15:46:03.110",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\", \"baseScore\": 3.8, \"baseSeverity\": \"LOW\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.0, \"impactScore\": 1.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}]}",
      "published": "2024-09-10T09:15:03.777",
      "references": "[{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000227015/dsa-2024-328\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "security_alert@emc.com",
      "vulnStatus": "Analyzed",
      "weaknesses": "[{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-788\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-42425\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2024-09-10T09:15:03.777\",\"lastModified\":\"2024-09-16T15:46:03.110\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.\"},{\"lang\":\"es\",\"value\":\"Las versiones de BIOS de Intel para Dell Precision Rack 14G anteriores a la 2.22.2 contienen una vulnerabilidad de acceso a la ubicaci\u00f3n de la memoria despu\u00e9s del final del b\u00fafer. Un atacante con pocos privilegios y acceso local podr\u00eda aprovechar esta vulnerabilidad, lo que provocar\u00eda la divulgaci\u00f3n de informaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\",\"baseScore\":3.8,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.0,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-788\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:precision_7920_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.22.1\",\"matchCriteriaId\":\"BC189661-C4D5-4711-B34A-472F81F2A134\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:precision_7920:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0BCCF11B-05BD-4E70-AD26-6B26A7E701FA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:7920_xl_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.22.1\",\"matchCriteriaId\":\"19274738-5950-4F0C-B721-5668789F5453\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:7920_xl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F2BB0803-F5C9-4D65-8462-971BCB19B824\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000227015/dsa-2024-328\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-42425\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-10T15:08:42.622659Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-10T15:08:48.851Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 3.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"LOW\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"Dell Precision Rack BIOS\", \"versions\": [{\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"2.22.1\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-09-05T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000227015/dsa-2024-328\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Access of Memory Location After End of Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-788\", \"description\": \"CWE-788: Access of Memory Location After End of Buffer\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2024-09-10T08:17:04.690Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-42425\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-10T15:08:54.037Z\", \"dateReserved\": \"2024-08-01T07:28:53.702Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2024-09-10T08:17:04.690Z\", \"assignerShortName\": \"dell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.